NOTES: For proper cable (wire rope) routing, starting at the piston;
A. Replace the cable (wire rope) thimble and wire rope clamp to one side of the cable.
B.Secure the cable (wire rope) to the piston mount with the
C.Feed the cable (wire rope) through the cylinder clevis assembly and around the outer lower right cable pulley, to the upper right cable pulley, to the inner lower right cable pulley, to the inner lower left cable pulley, to the outer lower left cable pulley, and to the cylinder clevis assembly.
D.Feed the cable (wire rope) through the wire rope clamp.
E.Feed the cable (wire rope) thimble through the turnbuckle adjustment rod.
F.Feed the cable (wire rope) around the wire rope thimble.
G.Feed the end of the cable (wire rope) through the wire rope clamp and tighten.
H.Adjust the turnbuckle to the proper cable (wire rope) tension.
8)To install new cable (wire rope), reverse Step #7 thru Step #3. (Refer to previous page [page 70].)
9)Reestablish the air supply to the dryer.
10)Reestablish electrical service to the dryer. c. Load Door Glass Window Replacement
1)Remove ALL of the old silicone from around the door glass.
2)Clean glass door opening (with alcohol) to
remove ALL foreign residue.
3) Carefully clean new door glass with alcohol prior to installation.
4) Apply a bead of silicone (ADC Part No. 170730) to the outer perimeter of the door glass opening.
5) Carefully insert new door glass within the door glass opening.
IMPORTANT: Allow a full 72 hours for the silicone to cure.
6)Carefully trim excess silicone (with a razor blade) after the cure time.
71