ADC AD-464 service manual PLC Programmable Logic Controller System

Page 48

SECTION VI

PLC (PROGRAMMABLE LOGIC CONTROLLER) SYSTEM

A. PLC (Programmable Logic Controller) DESCRIPTION

The heart of the dryer is a TSX17 PLC (Programmable Logic Controller) with twenty-one (21) inputs and twelve

(12)outputs. The TSX17 PLC also uses two (2) expansion modules, a relay output module with six (6) outputs, and a 4 mA - 20 mA (milliamphere) analog input module with four (4) inputs. The operator interface for the TSX17 PLC is the XBT digital display unit.

The TSX17 PLC's (Programmable Logic Controller's) main module zero ("0") inputs are as follows:

The "0" is used to sense that the 110 VAC control voltage has been turned on via the master control relay. If the master control failed to be turned on, the XBT unit will display "CNTRL VOLT OFF" (control voltage off).

Input 1 monitors the overloads (OL) for motors OL1, OL2, OL3, OL4, and on gas dryers OL8. The over- loads have auxiliary contacts in them that are tied in series from the control voltage to Input 0,1. In a case that an overload trips, the XBT unit will display a "motor fault."

Input 0,2 is used to monitor that the burner fan is on during a heat cycle. (This is not used on steam dryers and is tied to Input 0,10 on steam dryers.) In a case were there is a call for heat and the burner fan does not turn on, the dryer will display a "heater fault."

Input 0,3 main function is to sense if one (1) of the high limits have tripped due to excessively high temperature in the dryer. If the high limit trips, the XBT unit will display "HI-TEMP FAULT."

Input 0,4 monitors the gas pressure. If a high gas pressure or a low gas pressure situation arises, voltage is removed from Input 0,4 causing a heat cycle to be discontinued and a "GAS SUPPLY FAULT" to be displayed. On steam models, this input is tied to the PLC's (Programmable Logic Controller's) 110 VAC power source.

Input 0,5 is used to sense a clogged lint screen or obstruction in the exhaust via an air switch that is located in the lint collection area. A fault in the air flow produces an "AIR FLOW FAULT" message.

Input 0,6 is used to monitor the front load door if this load door is closed by means of DS1, A (Door Switch 1, A contacts). A drying cycle will not begin until Input 0,6 is on. If a cycle is started and the door is open, the XBT unit will display "DOOR OPEN."

Input 0,7 monitors the rear door via the DS2, A (Door Switch 2, A) contacts. A cycle cannot be begin until the doors are closed. If a cycle is started with the rear door open, the XBT unit will display "DOOR OPEN." in the case of one (1) door dryer, Input 0,7 is tied to 110 VAC.

Input 0,8 is used to monitor the two (2) lint drawers. This is achieved through two (2) proximity switches, one for each lint drawer. There is a magnet on each of the lint drawers, which when aligned with the proximity switch causes a contact closure which brings 110 VAC to Input 0,8. When a cycle is started and a lint drawer is not closed, the XBT unit will display "CHK. LINT DRAWER" (check lint drawer).

44

Image 48
Contents American Dryer Corporation Retain This Manual In a Safe Place For Future Reference Important Note to PurchaserFor Your Safety Page Table of Contents Section Pendant Assembly Section Sprinkler SystemSection AIR JET System Safety Precautions Explosion could ResultStandards National Electric Code ANSI/NFPA no -LATEST EditionRoutine Maintenance CleaningLiquids Monthly Lubrication Adjustments Days After Installation and Every 6 Months ThereafterSpecifications GAS Models ADG-464Steam Models ADS-464 Electrical Service Specifications ADG-464 GASInstallation Requirements Enclosure / AIR Supply / Exhaust RequirementsOperational Service Check Procedure Electrical Requirements and GAS RequirementsComponent DESCRIPTION/REPLACEMENT Tumbler Support and Drive SystemPage Main AIR BLOWER/HEAT Reclaimer System +Z=X Filter element can be cleaned with soap and water Compressed AIR SystemPage Page Page Safety Devices Safety Devices Locations/Functions/Messages Blower Squirrel Cage Fan Motor Assembly Pulley Removal Page Freely Important do not Overtighten V-BELTSImportant do not Overtighten V-BELTS Blower Squirrel Cage Fan Electrical Components Page Tumbler Basket System Page Page Important do not Overtighten Turnbuckle Important do not Overtighten Turnbuckle Result in Damage to the Dryer and will Void the Warranty Important do not Overtighten Bolts Page Rotational Sensor Assembly Current Limiting Device is RequiredPage TOP of Tumbler Basket Temperature Door Assembly Tumbler Basket Electrical Components Page PLC Programmable Logic Controller System PLC Programmable Logic Controller DescriptionPage Page 111 PLC Programmable Logic Controller Component Replacement Page Page RTD Page Switch #1 Recycling Mode Page Page Page Combustion Air Damper Page Page Page Burner Air Switch Page Page Page Page Page Page Heat Reclaimer Settings Page Page Important Allow a full 72 hours for the silicone to cure Page Page Page Page Lint DRAWER/LINT Chamber Switches Base SectionPage Page Resistive Temperature Device RTD RTD Resistive Temperature Device Locations Sprinkler System Sprinkler System DescriptionPage MAN3190 Page AIR JET System AIR JET SystemStack Valve Assembly Pneumatic ValveImportant Take Notice ... small components Page MAN4223 Internal Pilot and External Pilot Air Supply Pendant Assembly Pendant Assembly DescriptionADC450186 05/27/99-25 01/14/00-15