ADC AD-464 service manual

Page 47

2.Auxiliary Contact Block Description

The auxiliary contact block is mounted on the side of the overload. Its' function is to sense an overload trip, thereby triggering a safety fault which will disable the drying cycle. A motor fault message will appear on the display of the Telemecanique XBT unit.

a. Auxiliary Contact Block Replacement

1)Discontinue electrical service to the dryer.

2)Remove the thermal magnetic starter (TMS) from the din rail by pulling the tab on the bottom of the contact block and lift upward.

3)Remove the two (2) wires going to the auxiliary contact block and label for correct reinstallation.

4)There are two (2) types of auxiliary contact blocks...one style has a screw and the other style has a clip. In both styles, disassembly and assembly is recommended with the thermal magnetic starter (TMS) in the "STOP" position.

a)To remove the style that has the screw from the TMS, simply remove the screw.

b)To remove the style that has the clip, simply push the clip and twist the auxiliary contact block to remove.

5)To install new auxiliary contact block, reverse Step # 4 thru Step #2.

6)Reestablish electrical service to the dryer.

3.Varistor (MOV [Metal Oxide Varistor]) Description

The varistor (MOV) is used to suppress any inductive electrical spikes produced by the energizing and coil voltage.

a) Varistor (MOV [Metal Oxide Varistor]) Replacement

1)Discontinue electrical service to the dryer.

2)Loosen the screws marked A1 and A2 on the contactor.

3)Verify that no additional wires were inadvertently removed.

4)Reverse above procedure to install new varistor.

43

Image 47
Contents American Dryer Corporation Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section AIR JET System Section Pendant AssemblySection Sprinkler System Explosion could Result Safety PrecautionsNational Electric Code ANSI/NFPA no -LATEST Edition StandardsLiquids Routine MaintenanceCleaning Monthly Lubrication Days After Installation and Every 6 Months Thereafter AdjustmentsGAS Models ADG-464 SpecificationsSteam Models ADS-464 ADG-464 GAS Electrical Service SpecificationsEnclosure / AIR Supply / Exhaust Requirements Installation RequirementsElectrical Requirements and GAS Requirements Operational Service Check ProcedureTumbler Support and Drive System Component DESCRIPTION/REPLACEMENTPage Main AIR BLOWER/HEAT Reclaimer System +Z=X Compressed AIR System Filter element can be cleaned with soap and waterPage Page Page Safety Devices Safety Devices Locations/Functions/Messages Blower Squirrel Cage Fan Motor Assembly Pulley Removal Page Important do not Overtighten V-BELTS FreelyImportant do not Overtighten V-BELTS Blower Squirrel Cage Fan Electrical Components Page Tumbler Basket System Page Page Important do not Overtighten Turnbuckle Important do not Overtighten Turnbuckle Result in Damage to the Dryer and will Void the Warranty Important do not Overtighten Bolts Page Current Limiting Device is Required Rotational Sensor AssemblyPage TOP of Tumbler Basket Temperature Door Assembly Tumbler Basket Electrical Components Page PLC Programmable Logic Controller Description PLC Programmable Logic Controller SystemPage Page 111 PLC Programmable Logic Controller Component Replacement Page Page RTD Page Switch #1 Recycling Mode Page Page Page Combustion Air Damper Page Page Page Burner Air Switch Page Page Page Page Page Page Heat Reclaimer Settings Page Page Important Allow a full 72 hours for the silicone to cure Page Page Page Page Base Section Lint DRAWER/LINT Chamber SwitchesPage Page Resistive Temperature Device RTD RTD Resistive Temperature Device Locations Sprinkler System Description Sprinkler SystemPage MAN3190 Page AIR JET System AIR JET SystemPneumatic Valve Stack Valve AssemblyImportant Take Notice ... small components Page MAN4223 Internal Pilot and External Pilot Air Supply Pendant Assembly Description Pendant AssemblyADC450186 05/27/99-25 01/14/00-15