d.Load Door Closed Switch Replacement
1)Discontinue electrical service to the dryer.
2)Loosen and remove the two (2) screws securing the junction cover.
3)Remove the junction cover.
4)Mark and identify the wires that will be removed for proper reinstallation.
5)Remove the wires from the terminals.
6)Loosen and remove the two (2) mounting screws.
7)Loosen and remove the cord grip cap.
8)Remove the cord grip.
9)To install the new load door closed switch, reverse Step #8 thru Step #2.
10)Mount the coil spring lever arm in the 1 o'clock position.
NOTE: Verify that the body orientation and head orientation are correct.
IMPORTANT: Verify that the load door closed switch is not in the vertical position or damage will result.
11)Hold the coil spring lever arm and tighten up (snug up) on the nut.
12)Hold pivot point with a screwdriver and tighten the nut.
13)Reestablish electrical service to the dryer.
72