Output 1,4 is the blower (fan) Air Jet which is used to clean lint off of the fan (blower). At the end of a cycle, the Air Jet turns on for 30-seconds.

Output 1,5 is the End of Cycle light. Once the dryer has reached the end of a cycle, the output turns on, illuminating the End of Cycle light. The output will turn off once a load or unload command is asserted on the pendant.

ANALOG INPUT MODULE

The Analog Input Module is used to measure the temperature in the exhaust of the dryer. The Analog Input Module measures a 4 mA - 20 mA (milliamphere) signal (controlled by the TX58 Resistive Temperature Device [RTD] in conjunction with the 100(100 ohm) Platinum Resistance Thermometer and converts it to a corresponding temperature. The RTD has predetermined temperature to resistance characteristics. The following chart has a few examples;

ºF

ºC

RESISTANCE ()

32

0

100

75

24

109

86

30

111

199

93

135.84

The TX58 RTD (Resistive Temperature Device) converts the resistance of the RTD to a 4 mA - 20 mA (milliamphere) current loop. The current in the loop is equal to .022222 mA/(ºF - 32) + 4 mA (measurement in celsius [centigrade] is .04 mA/ºC + 4 mA.

Example: 200º F - 32 = 168 x .022222 = 3.73 mA + 4 mA = 7.73 mA 93º C x .04 mA = 3.72 + 4 mA = 7.72 mA

The power source for the TX58 RTD is PS1 (Power Supply 1) is a 24 VDC power supply mounted on the main electrical panel.

NOTE: There is approximately a 10º F (18º C) differential between the actual and the displayed

temperature on the XBT unit.

TELEMECANIQUE XBT UNIT

The Telemecanique XBT Unit is the user interface to the dryer. ALL the user commands are loaded into the XBT unit at the factory. System parameters are stored in the TSX17 PLC (Programmable Logic Controller) via the XBT unit interface. These are the drying recipes and parameters such as Load Level, Spin Time, Dwell Time, etc. The power source for the XBT unit is a 24 VDC power supply mounted on the main electrical panel. A data cable connects the XBT unit to the TSX17 PLC for communication purposes.

HOUR CLOCK

The dryer has a Hour Clock to keep track of how many hours the dryer has been running. The clock runs off the 24 VAC power supply through a set of contacts on the blower contactor. When the blower contactor closes, it also closes an additional set of contacts to activate the clock.

47

Image 51
Contents American Dryer Corporation Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Pendant Assembly Section Sprinkler SystemSection AIR JET System Explosion could Result Safety PrecautionsNational Electric Code ANSI/NFPA no -LATEST Edition StandardsRoutine Maintenance CleaningLiquids Monthly Lubrication Days After Installation and Every 6 Months Thereafter AdjustmentsGAS Models ADG-464 SpecificationsSteam Models ADS-464 ADG-464 GAS Electrical Service SpecificationsEnclosure / AIR Supply / Exhaust Requirements Installation RequirementsElectrical Requirements and GAS Requirements Operational Service Check ProcedureTumbler Support and Drive System Component DESCRIPTION/REPLACEMENTPage Main AIR BLOWER/HEAT Reclaimer System +Z=X Compressed AIR System Filter element can be cleaned with soap and waterPage Page Page Safety Devices Safety Devices Locations/Functions/Messages Blower Squirrel Cage Fan Motor Assembly Pulley Removal Page Important do not Overtighten V-BELTS FreelyImportant do not Overtighten V-BELTS Blower Squirrel Cage Fan Electrical Components Page Tumbler Basket System Page Page Important do not Overtighten Turnbuckle Important do not Overtighten Turnbuckle Result in Damage to the Dryer and will Void the Warranty Important do not Overtighten Bolts Page Current Limiting Device is Required Rotational Sensor AssemblyPage TOP of Tumbler Basket Temperature Door Assembly Tumbler Basket Electrical Components Page PLC Programmable Logic Controller Description PLC Programmable Logic Controller SystemPage Page 111 PLC Programmable Logic Controller Component Replacement Page Page RTD Page Switch #1 Recycling Mode Page Page Page Combustion Air Damper Page Page Page Burner Air Switch Page Page Page Page Page Page Heat Reclaimer Settings Page Page Important Allow a full 72 hours for the silicone to cure Page Page Page Page Base Section Lint DRAWER/LINT Chamber SwitchesPage Page Resistive Temperature Device RTD RTD Resistive Temperature Device Locations Sprinkler System Description Sprinkler SystemPage MAN3190 Page AIR JET System AIR JET SystemPneumatic Valve Stack Valve AssemblyImportant Take Notice ... small components Page MAN4223 Internal Pilot and External Pilot Air Supply Pendant Assembly Description Pendant AssemblyADC450186 05/27/99-25 01/14/00-15