Page 81

2.Lint Chamber Air Pressure Switch

The lint chamber air pressure switch utilized in the dryer is used to insure that there is proper air flow through the dryer. If there is a problem with this air pressure switch an "AIR FAULT" error message will be displayed via the L.E.D. (light emitting diode) on the Telemecanique XBT digital display unit.

a.Probable causes for an "AIR FAULT" error message;

1)Clogged lint screen.

2)Air pressure setting incorrect.

3)Air pressure switch (PS3) or wiring back to the PLC (Programmable Logic Controller).

b.Possible solutions;

1)Perform preventive maintenance and lint screen cleaning procedures.

2)Set correct air pressure setting.

3)For a quick check of the air pressure switch wiring, perform the following:

Run a drying cycle.

Does the air pressure switch's indicator come "ON"?

If yes, switch and its adjustment.

If no, check switch and its adjustment.

Verify that the PLC (Programmable Logic Controller) input L.E.D. (light emitting diode) #5 comes on.

Does L.E.D. #5 come "ON" when the switch is active?

If yes, wiring is okay.

If no, check the following:

Air pressure switch, its setting and wiring.

Check wiring back to base electrical junction box.

4)Junction Box

Check PLC (Programmable Logic Controller).

Refer to electric diagrams;

Electrical panel diagram.

Junction box diagram.

Retest; verify that the signal is operational.

77

Image 81
Contents American Dryer Corporation Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Pendant Assembly Section Sprinkler SystemSection AIR JET System Explosion could Result Safety PrecautionsNational Electric Code ANSI/NFPA no -LATEST Edition StandardsRoutine Maintenance CleaningLiquids Monthly Lubrication Days After Installation and Every 6 Months Thereafter AdjustmentsGAS Models ADG-464 SpecificationsSteam Models ADS-464 ADG-464 GAS Electrical Service SpecificationsEnclosure / AIR Supply / Exhaust Requirements Installation RequirementsElectrical Requirements and GAS Requirements Operational Service Check ProcedureTumbler Support and Drive System Component DESCRIPTION/REPLACEMENTPage Main AIR BLOWER/HEAT Reclaimer System +Z=X Compressed AIR System Filter element can be cleaned with soap and waterPage Page Page Safety Devices Safety Devices Locations/Functions/Messages Blower Squirrel Cage Fan Motor Assembly Pulley Removal Page Important do not Overtighten V-BELTS FreelyImportant do not Overtighten V-BELTS Blower Squirrel Cage Fan Electrical Components Page Tumbler Basket System Page Page Important do not Overtighten Turnbuckle Important do not Overtighten Turnbuckle Result in Damage to the Dryer and will Void the Warranty Important do not Overtighten Bolts Page Current Limiting Device is Required Rotational Sensor AssemblyPage TOP of Tumbler Basket Temperature Door Assembly Tumbler Basket Electrical Components Page PLC Programmable Logic Controller Description PLC Programmable Logic Controller SystemPage Page 111 PLC Programmable Logic Controller Component Replacement Page Page RTD Page Switch #1 Recycling Mode Page Page Page Combustion Air Damper Page Page Page Burner Air Switch Page Page Page Page Page Page Heat Reclaimer Settings Page Page Important Allow a full 72 hours for the silicone to cure Page Page Page Page Base Section Lint DRAWER/LINT Chamber SwitchesPage Page Resistive Temperature Device RTD RTD Resistive Temperature Device Locations Sprinkler System Description Sprinkler SystemPage MAN3190 Page AIR JET System AIR JET SystemPneumatic Valve Stack Valve AssemblyImportant Take Notice ... small components Page MAN4223 Internal Pilot and External Pilot Air Supply Pendant Assembly Description Pendant AssemblyADC450186 05/27/99-25 01/14/00-15