ADC AD-464 service manual Pendant Assembly Description

Page 95

SECTION XI

PENDANT ASSEMBLY

A. PENDANT ASSEMBLY DESCRIPTION

The pendant assembly is used on both the gas and steam model dryer. Within the pendant assembly there is a three (3) position selection switch used to tilt the dryer in the load tilted, unload tilted, or level position. When the load tilted or unload tilted selection is made, the load/unload door will open once the door signal has been received, and the dryer will tilt. The jog forward/jog reverse push buttons, when depressed individually, will cause the tumbler (basket) to turn clockwise (CW) for forward and counterclockwise (CCW) for reverse. If both push buttons are depressed together the jog feature is disabled due to the mechanical interlock with the pendant assembly. This feature is used as a safety device to prevent both drive motors from being energized in opposite directions.

The EMERGENCY STOP (E STOP) button is a push-to-stop and twist-to-release switch. When the E STOP button has been depressed the control power to the dryer is disabled. Voltage is still present at the dryer even though the EMERGENCY STOP (E STOP) has been depressed.

1.Pendant Assembly Switch

a. Pendant Assembly Switch Replacement

1)Discontinue electrical service to the dryer.

2)Remove the four (4) screws that secure the pendant body together.

3)Mark and identify the wires that will be removed for proper reinstallation.

4)Remove the wires from the contact block being replaced.

5)To install new contact block,

reverse Step #4 thru Step #2.

6) Reestablish electrical power to the dryer.

91

Image 95
Contents American Dryer Corporation Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section AIR JET System Section Pendant AssemblySection Sprinkler System Explosion could Result Safety PrecautionsNational Electric Code ANSI/NFPA no -LATEST Edition StandardsLiquids Routine MaintenanceCleaning Monthly Lubrication Days After Installation and Every 6 Months Thereafter AdjustmentsGAS Models ADG-464 SpecificationsSteam Models ADS-464 ADG-464 GAS Electrical Service SpecificationsEnclosure / AIR Supply / Exhaust Requirements Installation RequirementsElectrical Requirements and GAS Requirements Operational Service Check ProcedureTumbler Support and Drive System Component DESCRIPTION/REPLACEMENTPage Main AIR BLOWER/HEAT Reclaimer System +Z=X Compressed AIR System Filter element can be cleaned with soap and waterPage Page Page Safety Devices Safety Devices Locations/Functions/Messages Blower Squirrel Cage Fan Motor Assembly Pulley Removal Page Important do not Overtighten V-BELTS FreelyImportant do not Overtighten V-BELTS Blower Squirrel Cage Fan Electrical Components Page Tumbler Basket System Page Page Important do not Overtighten Turnbuckle Important do not Overtighten Turnbuckle Result in Damage to the Dryer and will Void the Warranty Important do not Overtighten Bolts Page Current Limiting Device is Required Rotational Sensor AssemblyPage TOP of Tumbler Basket Temperature Door Assembly Tumbler Basket Electrical Components Page PLC Programmable Logic Controller Description PLC Programmable Logic Controller SystemPage Page 111 PLC Programmable Logic Controller Component Replacement Page Page RTD Page Switch #1 Recycling Mode Page Page Page Combustion Air Damper Page Page Page Burner Air Switch Page Page Page Page Page Page Heat Reclaimer Settings Page Page Important Allow a full 72 hours for the silicone to cure Page Page Page Page Base Section Lint DRAWER/LINT Chamber SwitchesPage Page Resistive Temperature Device RTD RTD Resistive Temperature Device Locations Sprinkler System Description Sprinkler SystemPage MAN3190 Page AIR JET System AIR JET SystemPneumatic Valve Stack Valve AssemblyImportant Take Notice ... small components Page MAN4223 Internal Pilot and External Pilot Air Supply Pendant Assembly Description Pendant AssemblyADC450186 05/27/99-25 01/14/00-15