e.Load Door Closed Switch Adjustment
1)Discontinue electrical service to the dryer.
2)To adjust the coil spring lever arm, hold the arm with a #10 metric (10 mm) wrench and loosen the nut.
3)Place the coil spring lever arm in the 1 o'clock position.
IMPORTANT: Verify that the load door closed switch is not in the vertical position or damage will result.
4)Hold the coil spring lever arm and tighten up (snug up) on the nut.
5)Hold pivot point with a screwdriver and tighten the nut.
6)Reestablish electrical service to the dryer.
f. Main Door Switch Replacement
1) Discontinue electrical service to the dryer.
2) Mark and identify the wires that will be removed for proper reinstallation.
3) Remove the wires
4) To remove a contact block, loosen and remove the mounting screw.
NOTE: Contact Block #1 and Contact Block #2 is normally closed (N.C.) while Contact Block #3 and Contact Block #4 is normally open (N.O.).
5)To remove or replace operator, loosen the two (2) screws that hold the switch body away from the door.
6)Quarter turn the operator (in the direction shown in the above illustration) and remove.
7)Reinstall the wires removed in Step #3.
8)Reestablish electrical power to the dryer. g. Switch Bulb Replacement
1) Discontinue electrical service to the dryer.
2) Unscrew clear lens shield.
3) Unscrew colored lens.
4) Remove diffuser.
73