Mitsubishi Electronics FR-F700 FR-F740-400KFR-HEL-H400K, FR-F740-450KFR-HEL-H450K, Parameter List

Page 13

￿FR-F740-400K

3-φ12 hole

DC reactor supplied

12

315315

790

R/L1

T/L3

P1

U

W

 

S/L2

N/-

P/+

V

185

1300

1330

 

 

4.5

4.5

 

440

 

194

 

 

222

 

 

Rating plate

2-terminal

2-M8 eye nut

 

4- 15 hole

 

P1

P1

10

10

455

500

40

P

P

40

75

 

 

E

195

4-installation hole

 

220

(for M10 screw)

Within 250

 

Within 235

Earth (ground) terminal (for M8 screw)

* Remove the eye nut after installation of the product.

Inverter Type

Mass

(kg)

 

FR-F740-400K(FR-HEL-H400K)

50

(Unit: mm)

 

 

Features

 

 

 

 

 

 

 

 

Peripheral Devices

Why energy

savings?

 

 

 

 

 

 

 

Standard

Specifications

 

 

 

 

 

 

 

Outline

Dimension

Drawings

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Connection

Diagram

Terminal Specification

Explanation

 

 

 

 

 

 

 

Operation

Panel

 

 

 

 

 

 

 

￿FR-F740-450K

4-φ12 hole

1550

1580

12

 

 

4.5

4.5

300

300

300

440

 

995

950

R/L1 S/L2 T/L3 N/- P1 P/+

V

 

189

185

227

DC reactor supplied

Rating plate

2-terminal

2-M8 eye nut

 

4- 15 hole

 

P1

P1

10

10

455

500

40

P

P

40

75

 

 

E

195

4-installation hole

 

 

 

220

(for M10 screw)

Within 270

 

Within 240

Earth (ground) terminal (for M8 screw)

* Remove the eye nut after installation of the product.

Inverter Type

Mass

(kg)

 

FR-F740-450K(FR-HEL-H450K)

57

(Unit: mm)

Parameter

List

 

 

 

Explanations of Parameters

 

 

Protective

Functions

 

 

 

 

Options

 

 

 

 

Instructions

 

 

 

 

Motor

 

 

 

 

Compatibility

 

 

Warranty

 

 

 

 

Inquiry

 

 

14

Image 13
Contents FR-F700 Energy savings for buildings and factories as a whole Warranty Inquiry Outline Dimension DrawingsInverter FR-F700 Connection with Peripheral DevicesDamper control discharge side Why Can the Inverter Save Energy?Amount Inverter controlRating Standard SpecificationsType FR-F720-K Type FR-F740-KCan be selected Common specificationsOperating status Open collectorInverter Type Outline Dimension DrawingsFR-F720-0.75K 110 FR-F720-1.5K 125 FR-F740-0.75K to 2K are not provided With a cooling fanFR-F740-15K, 18.5K Wiring coverFR-F720-30K is Not provided with aFR-F740-75K 140 120 Inverter Type Mass295 185 FR-HEL-H75K FR-F740-90K 150 130 310 190 FR-HEL-H90KFR-F740-110KFR-HEL-H110K DC reactor suppliedMass kg MassMass Remove the eye nut after installation of the productFR-F740-400KFR-HEL-H400K Remove the eye nut after installation of the productFR-F740-450KFR-HEL-H450K Parameter ListOutline drawing Panel cutting dimension drawingPanel FR-DU07 M3 screw CableOption connector Terminal Connection DiagramMain circuit Control circuitType Terminal Specification ExplanationTerminal Name Description Preset detected frequency. *1 Relay output 1 alarmRelay OutputExplanation of the Operation Panel FR-DU07 Setting Operation mode switchoverBasic operation Parameter List Name Setting Range Increments Initial ValueRemarks FunctionJump 24 to101 100102 103139 135143 144179 178180 181262 261263 264872 867882 883Maximum/minimum Explanations of ParametersFrequency Starting frequency Jog operationStall prevention operation Speed and remote settingInput compensation of multi Pr , 23, 48, 49, 66, 148, 149, 154, 156Pr , 70 Selection of regeneration unit SettingSpeed display and speed Pr , 54, 158, 170, 171, 268, 563, 564, 867 Connection diagram Pr Remote setting functionPr.59 Setting Description Pr , 58, 162 to 165, 299Pr Energy saving control selection Retry function at alarmOccurrence Use the constant torque motorAnalog input selection Carrier frequency and SoftPWM selectionPr , 240 Pr , 242, 243, 252, 253Pr Output function of alarm code Pr. Reset selection, disconnected PU 75 detectionPr. Noise elimination at the analog 74 input Pr Prevention of parameter rewritePr. Simple magnetic flux vector 80, 90 control Pr Pr Operation mode selectionOff LED IndicationCommunication initial setting Adjustable 5 points V/FPr to Pr to 124, 331 to 337, 341 to 343Pr to 134, 575 to 577 PID control Pr Pr Pr , C2902 to C7905Analog input bias/gain calibration Analog input display unit changing PrPr. Parameter unit display language 145 selection Second function signal RTSelection of action conditions Pr Pr toTerminal assignment Pr. Operation selection of the 161 operation panelPr to 196 output terminal Function assignmentInput/output phase failure Pr. Selection of motor stopping 250 method and start signalPr Increase cooling fan life Pr to 247 Slip compensationPower failure stop mode Pr.261 = 261 to 266 power failurePr Parameter for manufacturer setting. Do not set Operation at instantaneousPr to 497 REM signal To determine Maintenance time of partsPr to 557 monitor signal Remote output functionFree parameter Pr. Regeneration avoidancePr to 899 Energy saving monitor 882 to 886 functionPr. C0900, C1901 Adjustment of terminal FM AM calibration Pr PU contrast adjustmentParameter clear, parameter copy Pr , CL, ALLC, Er.CL, PcpyProtective Functions Error message *2 Minor fault *4 Major failures *5Function Name Description Indication Regenerative overvoltage shutOptions Instructions Motor Supply short circuit RS-485 terminals power Was shortedOptions Option and Peripheral DevicesSeries Controller/SpeedOthers ManualStand-alone option Specifications, Structure, etcName type Name type Specifications, Structure, etc FR-BR-HK FR-BU-HKConnection example External connection diagram Outline dimension drawingsCable Resistor unit Resistance Mass Type ValueConverter Outline dimension Unit mm FR-HC- HK High power factorApplication of the sine wave filter Circuit configuration and connectionApplication condition Capacitor for sine wave filterPeripheral devices list EMC Filter Standard BreakerOn mA Precautions for Operation/Selection Precautions for Peripheral Device Selection Leakage currents NoiseNoise reduction examples Three 7kW Reference materials Phase Input Target Measures PowerInput Target Measures Power Capacity Connect the AC reactor or DC reactor60Hz torque reference Application to Motor50Hz torque reference Suppressing the surge voltage on the inverter sideFR-F500 L FR-F700 Warranty FA Center in Taiwan FA Center in North AmericaFA Center in Asean FA Center in Korea