Main Differences and Compatibilities with the FR-F500(L) Series

Item

FR-F500 (L)

FR-F700

 

Simple mode parameters 61

Simple mode parameters 15

 

 

Pr. 0 Torque boost initial value

 

Pr. 0 Torque boost initial value

11K to 37K: 2%, 45K, 55K: 1.5%

 

(When the torque boost value of the FR-F500 series

 

11K to 55K: 2%

used was the initial value, it is not necessary to change

 

 

the torque boost value from the initial value when

 

 

replacing with the FR-F700 series.)

 

User group 1 (16), user group 2 (16)

User group (16) only

 

Setting methods were partially changed

 

(Pr. 160, Pr. 173 to Pr. 175)

 

(Pr. 160, Pr. 172 to Pr. 173)

 

 

 

 

"User initial value setting" (Pr. 199) was cleared

Changed/cleared

User initial value setting (Pr. 199)

Substitutable with the copy function of the operation

functions

 

panel (FR-DU07)

 

DC injection brake function with terminal (X13 signal)

DC injection brake function with terminal was cleared

 

(Pr. 11 setting value 8888, Pr. 180 to Pr. 186 setting

Start in reverse rotation is possible with flying start

 

function (frequency search of automatic restart after

 

value 13)

 

instantaneous power failure function)

 

 

 

Long wiring mode

Setting is not necessary

 

(Pr. 240 setting 10, 11)

(Pr. 240 settings "10" and "11" were cleared)

 

Intelligent optimum acceleration/deceleration

Function was cleared

 

For deceleration time, overvoltage alarm can be avoided

 

(Pr. 60 setting "3" and Pr. 61 to Pr. 63)

 

with regeneration avoidance function (Pr. 882 to Pr. 885).

 

 

 

Automatic torque boost

Automatic torque boost was cleared because of addition

 

(Pr. 38, Pr. 39)

of "Simple magnetic flux vector" (Pr. 80)

Terminal block

Removable terminal block

Removable terminal block

Priority compatibility (Terminal block of the F500 can be

 

 

mounted)

PU

FR-PU04, DU04

FR-DU07

FR-DU04 unavailable (Partly restricted when the FR-

 

 

PU04 is used.)

 

Dedicated plug-in

option (not compatible)

Plug-in option

Computer link, relay output option

Built into the inverter

FR-A5NR

(RS-485 terminals, relay output 2 points)

 

 

Three boards can be mounted

One board can be mounted

 

FR-F720-0.75K, 2.2K, 3.7K, 7.5K, 18.5K, 22K, 37K, 45K,

Installation size

FR-F740-0.75K to 3.7K, 7.5K, 22K, 37K to 55K are compatible in mounting dimensions

 

For other capacities, an optional intercompatibility attachment (FR-AAT) is necessary.

 

 

Features

 

 

 

 

 

 

 

 

Peripheral Devices

Why energy

savings?

 

 

 

 

 

 

 

Standard

Specifications

 

 

 

 

 

 

 

Outline

Dimension

Drawings

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Connection

Diagram

Terminal Specification

Explanation

 

 

 

 

 

 

 

Operation

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

List

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanations

of

Parameters

 

 

 

 

 

 

 

Protective

Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatibility

 

 

 

 

 

 

 

 

 

 

Warranty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inquiry

 

 

 

 

 

 

 

 

64

Image 63
Contents FR-F700 Energy savings for buildings and factories as a whole Warranty Inquiry Outline Dimension DrawingsInverter FR-F700 Connection with Peripheral DevicesInverter control Why Can the Inverter Save Energy?Damper control discharge side AmountType FR-F740-K Standard SpecificationsRating Type FR-F720-KOpen collector Common specificationsCan be selected Operating statusFR-F740-0.75K to 2K are not provided With a cooling fan Outline Dimension DrawingsInverter Type FR-F720-0.75K 110 FR-F720-1.5K 125Not provided with a Wiring coverFR-F740-15K, 18.5K FR-F720-30K is310 190 FR-HEL-H90K Inverter Type MassFR-F740-75K 140 120 295 185 FR-HEL-H75K FR-F740-90K 150 130Mass DC reactor suppliedFR-F740-110KFR-HEL-H110K Mass kgMass Remove the eye nut after installation of the productParameter List Remove the eye nut after installation of the productFR-F740-400KFR-HEL-H400K FR-F740-450KFR-HEL-H450KM3 screw Cable Panel cutting dimension drawingOutline drawing Panel FR-DU07Control circuit Terminal Connection DiagramOption connector Main circuitTerminal Specification Explanation TypeTerminal Name Description Output Relay output 1 alarmPreset detected frequency. *1 RelayExplanation of the Operation Panel FR-DU07 Operation mode switchover SettingBasic operation Function Name Setting Range Increments Initial ValueParameter List RemarksJump 24 to103 100101 102144 135139 143181 178179 180264 261262 263883 867872 882Explanations of Parameters Maximum/minimumFrequency Starting frequency Jog operationPr , 23, 48, 49, 66, 148, 149, 154, 156 Speed and remote settingStall prevention operation Input compensation of multiSetting Pr , 70 Selection of regeneration unitSpeed display and speed Pr , 54, 158, 170, 171, 268, 563, 564, 867 Pr , 58, 162 to 165, 299 Pr Remote setting functionConnection diagram Pr.59 Setting DescriptionUse the constant torque motor Retry function at alarmPr Energy saving control selection OccurrencePr , 242, 243, 252, 253 Carrier frequency and SoftPWM selectionAnalog input selection Pr , 240Pr Prevention of parameter rewrite Pr. Reset selection, disconnected PU 75 detectionPr Output function of alarm code Pr. Noise elimination at the analog 74 inputLED Indication Pr Pr Operation mode selectionPr. Simple magnetic flux vector 80, 90 control OffPr to 124, 331 to 337, 341 to 343 Adjustable 5 points V/FCommunication initial setting Pr toAnalog input display unit changing Pr Pr Pr Pr , C2902 to C7905Pr to 134, 575 to 577 PID control Analog input bias/gain calibrationPr Pr to Second function signal RTPr. Parameter unit display language 145 selection Selection of action conditionsFunction assignment Pr. Operation selection of the 161 operation panelTerminal assignment Pr to 196 output terminalPr to 247 Slip compensation Pr. Selection of motor stopping 250 method and start signalInput/output phase failure Pr Increase cooling fan lifeOperation at instantaneous 261 to 266 power failurePower failure stop mode Pr.261 = Pr Parameter for manufacturer setting. Do not setRemote output function To determine Maintenance time of partsPr to 497 REM signal Pr to 557 monitor signal882 to 886 function Pr. Regeneration avoidanceFree parameter Pr to 899 Energy saving monitorPr , CL, ALLC, Er.CL, Pcpy Pr PU contrast adjustmentPr. C0900, C1901 Adjustment of terminal FM AM calibration Parameter clear, parameter copyRegenerative overvoltage shut Error message *2 Minor fault *4 Major failures *5Protective Functions Function Name Description IndicationOptions Instructions Motor Supply short circuit RS-485 terminals power Was shortedOptions Option and Peripheral DevicesManual Controller/SpeedSeries OthersSpecifications, Structure, etc Stand-alone optionName type Name type Specifications, Structure, etc FR-BU-HK FR-BR-HKConnection example Resistor unit Resistance Mass Type Value Outline dimension drawingsExternal connection diagram CableConverter Outline dimension Unit mm FR-HC- HK High power factorCapacitor for sine wave filter Circuit configuration and connectionApplication of the sine wave filter Application conditionPeripheral devices list Standard Breaker EMC FilterOn mA Precautions for Operation/Selection Precautions for Peripheral Device Selection Noise Leakage currents Noise reduction examples Connect the AC reactor or DC reactor Input Target Measures PowerThree 7kW Reference materials Phase Input Target Measures Power CapacitySuppressing the surge voltage on the inverter side Application to Motor60Hz torque reference 50Hz torque referenceFR-F500 L FR-F700 Warranty FA Center in Korea FA Center in North AmericaFA Center in Taiwan FA Center in Asean