Mitsubishi Electronics FR-F700 135, 139, 143, 144, 145, 148, 149, 150, 151, 152, 153, 154, 155

Page 23

Function

Parameters

Name

Setting Range

Increments

Initial Value

Refer to

page

 

 

 

 

 

 

 

 

 

 

 

135

Commercial power-supply switchover

0, 1

1

0

39

Commercialpower

 

 

sequence output terminal selection

supply-inverter

 

 

 

 

 

 

switch-over

139

between inverter and commercial power-

0 to 60Hz, 9999

0.01Hz

9999

39

 

 

 

136

MC switchover interlock time

0 to 100s

0.1s

1s

39

 

 

 

137

Waiting time at a start

0 to 100s

0.1s

0.5s

39

 

 

 

138

Commercial power-supply operation

0, 1

1

0

39

 

 

 

switchover selection at an alarm

 

 

 

 

 

 

 

 

 

 

 

 

Automatic switchover frequency

 

 

 

 

 

 

 

 

supply operation

 

 

 

 

 

 

 

140

Backlash acceleration stopping

0 to 400Hz

0.01Hz

1Hz

30

Backlash measures

frequency

 

 

 

 

 

142

frequency

0 to 400Hz

0.01Hz

1Hz

30

 

 

 

141

Backlash acceleration stopping time

0 to 360s

0.1s

0.5s

30

 

 

 

 

Backlash deceleration stopping

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

143

Backlash deceleration stopping time

0 to 360s

0.1s

0.5s

30

 

 

 

144

Speed setting switchover

0, 2, 4, 6, 8, 10, 102, 104,

1

4

31

 

 

106, 108, 110

 

 

 

 

 

 

 

 

 

PU

 

145

PU display language selection

0 to 7

1

0

40

 

 

 

 

 

 

 

 

 

 

detection

 

148

Stall prevention level at 0V input.

0 to 150%

0.1%

120%

30

 

 

149

Stall prevention level at 10V input.

0 to 150%

0.1%

150%

30

 

 

 

 

 

 

150

Output current detection level

0 to 150%

0.1%

120%

40

 

Current

 

151

Output current detection signal delay

0 to 10s

0.1s

0s

40

 

 

time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

152

Zero current detection level

0 to 150%

0.1%

5%

40

 

 

 

153

Zero current detection time

0 to 1s

0.01s

0.5s

40

 

 

 

154

Voltage reduction selection during stall

0, 1

1

1

30

 

 

prevention operation

 

 

 

 

 

 

 

 

 

 

155

RT signal reflection time selection

0, 10

1

0

40

 

 

156

Stall prevention operation selection

0 to 31, 100, 101

1

0

30

 

 

157

OL signal output timer

0 to 25s, 9999

0.1s

0s

30

 

 

 

158

AM terminal function selection

1 to 3, 5, 6, 8 to 14, 17, 21,

1

1

32

 

 

24, 50, 52, 53

 

 

 

 

 

 

 

 

 

 

 

159

Automatic switchover ON range

0 to 10Hz, 9999

0.01Hz

9999

39

 

 

between commercial power-supply and

 

 

 

 

inverter operation

 

 

 

 

 

 

￿160

User group read selection

0, 1, 9999

1

9999

40

 

 

 

161

Frequency setting/key lock operation

0, 1, 10, 11

1

0

41

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

162

Automatic restart after instantaneous

0, 1, 10, 11

1

0

33

Automatic

 

functions

power failure selection

restart

 

 

 

 

 

163

First cushion time for restart

0 to 20s

0.1s

0s

33

 

 

 

 

 

 

164

First cushion voltage for restart

0 to 100%

0.1%

0%

33

 

 

 

165

Stall prevention operation level for

0 to 150%

0.1%

120%

33

 

 

 

restart

 

 

 

 

 

 

 

 

Current detection

167

Output current detection signal retention

0, 1

1

0

40

selection

 

 

 

166

time

0 to 10s, 9999

0.1s

0.1s

40

 

 

 

 

Output current detection operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

168

Parameter for manufacturer setting. Do not set.

 

 

 

 

 

169

 

 

 

 

 

 

 

 

 

 

Cumulative

monitor

 

170

Cumulative power meter clear

0, 10, 9999

1

9999

32

clear

171

Operation hour meter clear

0, 9999

1

9999

32

 

 

 

 

 

 

 

 

 

 

 

 

User group

172

User group registered display/batch

9999, (0 to 16)

1

0

40

clear

 

 

 

 

 

173

User group registration

0 to 999, 9999

1

9999

40

 

 

 

 

 

 

174

User group clear

0 to 999, 9999

1

9999

40

 

 

Features

 

 

 

 

 

 

 

 

Peripheral Devices

Why energy

savings?

 

 

 

 

 

 

 

Standard

Specifications

 

 

 

 

 

 

 

Outline

Dimension

Drawings

 

 

 

 

 

 

 

 

 

 

 

 

Terminal Connection

Diagram

Terminal Specification

Explanation

 

 

 

 

 

 

 

Operation

Panel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

List

 

 

 

 

 

 

 

 

 

 

 

 

 

Explanations

of

Parameters

 

 

 

 

 

 

 

Protective

Functions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Options

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Instructions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatibility

 

 

 

 

 

 

 

 

 

 

Warranty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inquiry

 

 

 

 

 

 

 

 

24

Image 23
Contents FR-F700 Energy savings for buildings and factories as a whole Warranty Inquiry Outline Dimension DrawingsInverter FR-F700 Connection with Peripheral DevicesInverter control Why Can the Inverter Save Energy?Damper control discharge side AmountType FR-F740-K Standard SpecificationsRating Type FR-F720-KOpen collector Common specificationsCan be selected Operating statusFR-F740-0.75K to 2K are not provided With a cooling fan Outline Dimension DrawingsInverter Type FR-F720-0.75K 110 FR-F720-1.5K 125Not provided with a Wiring coverFR-F740-15K, 18.5K FR-F720-30K is310 190 FR-HEL-H90K Inverter Type MassFR-F740-75K 140 120 295 185 FR-HEL-H75K FR-F740-90K 150 130Mass DC reactor suppliedFR-F740-110KFR-HEL-H110K Mass kgMass Remove the eye nut after installation of the productParameter List Remove the eye nut after installation of the productFR-F740-400KFR-HEL-H400K FR-F740-450KFR-HEL-H450KM3 screw Cable Panel cutting dimension drawingOutline drawing Panel FR-DU07Control circuit Terminal Connection DiagramOption connector Main circuitTerminal Name Description Terminal Specification ExplanationType Output Relay output 1 alarmPreset detected frequency. *1 RelayExplanation of the Operation Panel FR-DU07 Basic operation Operation mode switchoverSetting Function Name Setting Range Increments Initial ValueParameter List RemarksJump 24 to103 100101 102144 135139 143181 178179 180264 261262 263883 867872 882Frequency Explanations of ParametersMaximum/minimum Starting frequency Jog operationPr , 23, 48, 49, 66, 148, 149, 154, 156 Speed and remote settingStall prevention operation Input compensation of multiSpeed display and speed SettingPr , 70 Selection of regeneration unit Pr , 54, 158, 170, 171, 268, 563, 564, 867 Pr , 58, 162 to 165, 299 Pr Remote setting functionConnection diagram Pr.59 Setting DescriptionUse the constant torque motor Retry function at alarmPr Energy saving control selection OccurrencePr , 242, 243, 252, 253 Carrier frequency and SoftPWM selectionAnalog input selection Pr , 240Pr Prevention of parameter rewrite Pr. Reset selection, disconnected PU 75 detectionPr Output function of alarm code Pr. Noise elimination at the analog 74 inputLED Indication Pr Pr Operation mode selectionPr. Simple magnetic flux vector 80, 90 control OffPr to 124, 331 to 337, 341 to 343 Adjustable 5 points V/FCommunication initial setting Pr toAnalog input display unit changing Pr Pr Pr Pr , C2902 to C7905Pr to 134, 575 to 577 PID control Analog input bias/gain calibrationPr Pr to Second function signal RTPr. Parameter unit display language 145 selection Selection of action conditionsFunction assignment Pr. Operation selection of the 161 operation panelTerminal assignment Pr to 196 output terminalPr to 247 Slip compensation Pr. Selection of motor stopping 250 method and start signalInput/output phase failure Pr Increase cooling fan lifeOperation at instantaneous 261 to 266 power failurePower failure stop mode Pr.261 = Pr Parameter for manufacturer setting. Do not setRemote output function To determine Maintenance time of partsPr to 497 REM signal Pr to 557 monitor signal882 to 886 function Pr. Regeneration avoidanceFree parameter Pr to 899 Energy saving monitorPr , CL, ALLC, Er.CL, Pcpy Pr PU contrast adjustmentPr. C0900, C1901 Adjustment of terminal FM AM calibration Parameter clear, parameter copyRegenerative overvoltage shut Error message *2 Minor fault *4 Major failures *5Protective Functions Function Name Description IndicationOptions Instructions Motor Supply short circuit RS-485 terminals power Was shortedOptions Option and Peripheral DevicesManual Controller/SpeedSeries OthersName type Specifications, Structure, etcStand-alone option Name type Specifications, Structure, etc Connection example FR-BU-HKFR-BR-HK Resistor unit Resistance Mass Type Value Outline dimension drawingsExternal connection diagram CableConverter Outline dimension Unit mm FR-HC- HK High power factorCapacitor for sine wave filter Circuit configuration and connectionApplication of the sine wave filter Application conditionPeripheral devices list On mA Standard BreakerEMC Filter Precautions for Operation/Selection Precautions for Peripheral Device Selection Noise reduction examples NoiseLeakage currents Connect the AC reactor or DC reactor Input Target Measures PowerThree 7kW Reference materials Phase Input Target Measures Power CapacitySuppressing the surge voltage on the inverter side Application to Motor60Hz torque reference 50Hz torque referenceFR-F500 L FR-F700 Warranty FA Center in Korea FA Center in North AmericaFA Center in Taiwan FA Center in Asean