| Name | Type |
| Applications, Specifications, etc. |
|
| Applicable | |||
|
|
|
| Inverter | ||||||
|
|
|
|
|
|
|
|
|
| |
Controller | Manual controller |
| For independent operation. With frequency meter, frequency |
| ||||||
setting potentiometer and start switch. |
|
|
|
| ||||||
|
|
|
|
|
| |||||
DC tach. follower |
| For synchronous operation (1.5VA) by external signal (0 to |
| |||||||
5V, 0 to 10V DC) * |
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||
Three speed selector | For | three speed | switching, among | high, middle | and | low |
| |||
Controller/Speed |
| |||||||||
speed operation (1.5VA) * |
|
|
|
| ||||||
|
|
|
|
|
| |||||
Motorized speed setter |
| For remote operation. Allows operation to be controlled from |
| |||||||
several places (5VA) * |
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||
Ratio setter | For ratio operation. Allows ratios to be set to five inverters. |
| ||||||||
(3VA) * |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
| |||
PG follower |
| For tracking operation by a pilot generator (PG) signal (3VA) |
| |||||||
* |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
| Master controller (5VA) | for parallel | operation of | multiple |
| ||||
Manual | Master controller |
|
| |||||||
(maximum 35) inverters. * |
|
|
| Shared among all | ||||||
|
|
|
|
| ||||||
|
| For soft start and stop. Enables acceleration/deceleration in | ||||||||
Soft starter | models | |||||||||
Series |
|
| parallel operation (3VA) * |
|
|
|
|
| ||
Deviation detector |
| For continuous speed control operation. Used in combination |
| |||||||
with a deviation sensor or synchro (5VA) * |
|
|
| |||||||
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
FR | Preamplifier | Used as an A/V converter or arithmetic amplifier (3VA) * |
|
| ||||||
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
| |||||
| Pilot generator | For tracking operation. 70V/35VAC 500Hz (at 2500r/min) |
|
| ||||||
| Deviation sensor | For continuous speed control operation (mechanical |
|
|
| |||||
| deviation detection). Output 90VAC/90° |
|
|
| ||||||
|
|
|
|
|
| |||||
Others | Frequency setting potentiometer | WA2W 1kΩ | For frequency setting. Wirewound 2W 1kΩ B characteristic |
| ||||||
Frequency meter | YM206NRI 1mA | Dedicated frequency meter (graduated to 120Hz). Moving- |
| |||||||
coil type DC ammeter |
|
|
|
|
| |||||
|
|
|
|
|
|
| ||||
Calibration resistor | RV24YN 10kΩ | For | frequency | meter | calibration. | Carbon film | type | B |
| |
|
| |||||||||
| characteristic |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
| Inverter setup software |
| Supports an inverter startup to maintenance. |
|
| Shared among all | ||||
| (FR Configrator) | WE |
|
| models | |||||
|
|
|
|
|
|
|
|
*Rated power consumption. The power supply specifications of the FR series manual controllers and speed controllers are 200VAC 50Hz, 220V/ 220VAC 60Hz, and 115VAC 60Hz.
|
| Features |
|
| |
|
|
| |||
|
|
| |||
Peripheral Devices | Why energy | savings? | |||
|
|
|
|
|
|
| Standard | Specifications |
| ||
|
|
|
|
|
|
Outline | Dimension | Drawings | |||
|
|
|
|
|
|
|
|
|
|
|
|
Terminal Connection | Diagram | Terminal Specification | Explanation | ||
|
|
|
|
|
|
| Operation | Panel |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| Parameter | List |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
Explanations | of | Parameters | |||
|
|
|
|
|
|
| Protective | Functions |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| Options |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Instructions |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Motor |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Compatibility |
|
| |
|
|
|
|
|
|
|
| Warranty |
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Inquiry |
|
| |
|
|
|
|
|
|