Dynacord CMS 1000, 1600, 2200 owner manual Important Safety Instructions

Page 3

IMPORTANT SAFETY INSTRUCTIONS

The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated „dangerous voltage“ within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintance (servicing) instructions in the literature accompanying the appliance.

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with a dry cloth.

7.Do not block any ventilation openings. Install in accordance with the manufactures instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrican for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.Only use attachments/accessories specified by the manufacturer.

12.Unplug this apparatus during lightning storms or when unused for long periods of time.

13.Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

14.Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment.

15.To completely disconnect this equipment from the AC Mains, disconnect the power supply cord plug from the AC receptacle.

16.The mains plug of the power supply cord shall remain readily operable.

 

IMPORTANT SERVICE INSTRUCTIONS

CAUTION:

These servicing instructions are for use by qualified personnel only. To reduce the risk of

 

electric shock, do not perform any servicing other than that ontained in the Operating

 

Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel.

1.Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65) and the CSA E65 - 94 have to be obeyed when servicing the appliance.

2.Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains.

3.Switch off the power before retrofitting any extensions, changing the mains voltage or the output voltage.

4.The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times.

5.Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts.

6.Altering the circuitry without prior consent or advice is not legitimate.

7.Any work security regulations that are applicable at the location where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself.

8.All instructions concerning the handling of MOS - circuits have to be observed.

NOTE:

SAFETY COMPONENT ( MUST BE REPLACED BY ORIGINAL PART )

3

Image 3
Contents CMS 1000/1600/2200 Contents InhaltsverzeichnisTable DES Matières Important Safety Instructions Unpacking and Warranty Installation and ConnectionsDescriptions Input Mono MICLine Setting Instructions InsertGain LO CUT 80 Hz Voicing FilterEQ Section AUX 3/4 AUX / FX 1/2Mute Signal / Peak IndicatorVolume PANGain MIC Input Stereo15.MIC Stereo Input L/MONO RLine Trim EQ SectionAUX / FX 1/2 AUX3/4 BAL SIGNAL/PEAK 27/28. AUX1/2 Send Effects 1/2FX1/FX2 Changing FX Start ProgramsEffect Return Display30. UP/DOWN Peak LEDAUX3/4 Post AUX3&4 / MasterAUX3/4 OUT AUX3/4 InsertsAUX3/4 Volume Power AnzeigeBand Equalizer PFL Master MasterMaster LED-DISPLAY StandbyRecord Send L/R Mono OutputMono OUT Level & PRE/POST Phones LevelLamp XLR FootswitchMaster OUT Master InsertsRear Panel PowerUnbalanced CablingCabling LF-Cables Balanced or Unbalanced?Sound Check Setting UP a STANDARD-PA SystemMonitor Mix Main MixOptional Subwoofer Monitoring Setup ExamplesSetup Examples Setup Examples Wichtige Sicherheitshinweise Auspacken und Garantie BeschreibungLine Gain Klangregelung Einstellhinweis Signal / PEAK- Anzeige Input Stereo +20 +15 +10 100 200 500 10k 20k AUX / FX Umstellung der Effekt-Startprogramme Effekt 1/2Effekt Return EinstellhinweiseAUX3/4 +20 +15 +10 100 200 500 10k Master LED-DISPLAY Phones Mono OUT LevelMaster OUT Rückseite Verkabelung Aufbau Einer STANDARD-PASoundcheck AufbauMonitormix HauptmixAufbau Beispiele Aufbaubeispiele Aufbaubeispiele Instructions DE Sécurité Importantes Déballage et garantie Installation et BranchementsLine Ligne Entrée MonoConseils de réglage Insert InsertionLO CUT 80 Hz Filtre coupe-bas Voicing Filter Filtre de VoixEQ Section Égaliseur AUX/FX 1/2 Auxiliaires/Effets Instructions de réglageIndicateur SIGNAL/PEAK Entrée Stéréo BAL ance Section EQAUX/FX 1/2 21.AUX3/4SIGNAL/PEAK Changer les effets de démarrage Effets 1/2Effect Return Retour D’EFFET Afficheur31/32. FX1/2 à AUX3/4 Temoin PeakAUX3&4 / Master 44. Égaliseur 7 Bandes 45. Témoin Power46. Échelle DE LED Master Master L+REQ to Affectation de l‘EQ Track Return L/R Retour 2 Pistes Mono OUTNiveau Mono OUT ET PRE/POST Phones Sortie casquesMaster Inserts Insertions principales Master OUT Sortie généralePanneau Arrière Cablage CâblageCâbles basse fréquence Symétrisés ou non symétrisés ? Installation D‘UN Système DE Sonorisation Mixage des retours Monitor Mixage principalExemples D‘INSTALLATION Exemples D‘INSTALLATION Exemples D‘INSTALLATION Specifications Block Diagram Dimensions / Abmessungen Effect presets Effekt Presets Programmes Effets