TROUBLESHOOTING
PROBLEM | CHECK and CURE | IMPORTANT |
ELECTRONIC IGNITION | Be sure you have a fresh battery installed. | Verify that the battery is in good condition |
| Be sure that there is gas fl ow to the burners by attempting to match light your burners. If match | and installed correctly. |
| lighting is successful, the problem lies somewhere in the ignition system and will need to be |
|
| checked. |
|
| • Check that all wires are connected to the ignition box (1). | If for any reason the igniter system is still |
| • Be sure that wires are correctly inserted into teminals (2) on ignition box. | |
| inoperative, follow match lighting instructions. | |
|
| |
|
|
|
MAIN GRILLING BURNERS | CAUTION: Always turn the gas supply off at the tank before | If the main burner(s) still fails to ignite, make |
| proceeding with any troubleshooting procedures. | sure that there is gas fl owing to the burner(s) |
| by attempting to match light the burner(s). | |
|
| |
| WARNING: The hood must be in the full open position any time you | If the burners will match light, then proceed |
| attempt to light your grill. Failure to open the hood could lead to | with the ignition checkout. |
| If for any reason the igniter system is still | |
| delayed ignition, resulting in bodily harm. | |
| inoperative, follow match lighting instructions. | |
|
|
|
| After shutting off the main gas supply, remove the cook grate and heat distribution plates. Push |
|
| the igniter button and check if the electrode is sparking to the igniter tube. Try pushing and |
|
| holding the igniter so that it clicks several times. |
|
|
|
|
BURNERS WITH POOR FLAME | Check to be sure burner ports, shutter, end of the burner (venturi) and orifi ce(s) are free of any | If you still have a poor fl ame, please contact |
| obstructions. Also, if your grill has been stored over a prolonged period of time, check to make | dealer for futher assistance or call Customer |
| sure no spiderwebs have been formed in the shutter end of the burner (venturi) or over orifi ces. | Service at |
On an LP grill, if an extremely low fl ame is present, or is hard to ignite, the fl
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area by calling
23