‰ID Memory contents.

The scale ID memory can contain unit weights with tare weights and comparator limits, or just unit weights alone.

00 ID memory contains the unit weight only.

Tare Weight

00

Comparator limits

You select which data to be stored by keying in a

0or 1 for the data: tare weight or comparator limits.

Example: Key in 1 0 to display 10, ID memory contains the unit weight and comparator limits.

F-02-X ACAI Operation & Min. Unit Weight

f-02-01

‰ACAI Mode When Unit Weight entered by Sample Pieces.

0

ACAI is disabled.

 

 

 

 

1

ACAI automatic Operation.

 

 

 

 

2

ACAI Manual Mode (using the

 

key).

ENTER

 

 

 

 

f-02-02

‰ACAI Mode When Unit Weight entered by Keyboard or ID.

0

ACAI is disabled.

 

 

 

 

1

ACAI Manual Mode (using the

ENTER

key). This setting

works when f-02-01setting is not “0”.

 

2

ACAI Automatic obeys f-02-01setting.

f-02-03

‰Minimum Unit Weight. (1d=1 weighing display division) The factory setting may be different for some countries.

0

1/5 d

 

 

1

1/100 d

32

Image 34
Contents Counting Scale This manual and Marks Contents AWA Audible Weighing Assist Introduction FeaturesIntroduction Unpacking Parts OverviewCalibration Setting Up Your ScaleBest Conditions For Weighing ON/OFF880000.880.00000 TotalId-00 888.8.888.0 Automatic Last Unit Weight Used0000 Front Panel Overview 880000.8 Turn The Power on and OFFBasic Operations Basic OperationsTare TareTo Start Counting Add Unit Weight By a Sample888.8.88.10 Add0000 Add 888.8.88.500280 Add 0000 Add 888.8.88.200112 Add 0000 888.8.882.0Key 888.8.8810 Unit Weight By Keyboard0000 Lo ut 0000 Id-00 Unit Weight By ID NumberReset Id-12888.8.881.0 Entering a Tare WeightUsing the Keyboard Tare Key 0615To Clear Tare 888.8.-554888.8-554 EitherStore Unit Weight by ID Numbers Store Unit WeightId-00 Clear idall Clear Id-00Clear Id-12 Clearing All ID Memories at OnceUnit Weight, Tare & Comparator Limits Memorized Key, the tare and/or comparator limitsM+ Memory Function Using the M+ MemoryAdding Using the M+ Key To Erase the Last M+ AdditionClearing the M+ Total Automatic M+ Accumulation ModeViewing the M+ Total M- FunctionComparator Function 888881008f-00810 8f-05810 To Set the Comparator888.8.-198 888.8888.8.-102 Viewing Comparator Limits888Cal10 Calibration Procedure Using a Weight888Cal02 CalibrationCal f 5000 Cal 50015000 50009800 Gravity CompensationTo Change or View F-Function Settings Function Parameters01-01 00-0100-02 01-0202-01 Acai Operation & Min. Unit Weight01-05 02-0204-01 03-0103-02 04-0205-01 05-02 05-04 05-05 04-05Comparator 06-04 06-01 06-0206-03 RS-232C Data Output09-02 06-0509-01 09-X KeyAcai Function 8888882888888821 Acai Automatic OperationWeighing Pan Addition Range Acai Manual OperationPcs On Stable Acai888.off02 To Enable/Disable AWA FunctionOff Mode Setting AWA FunctionTarget 888.of100888.of150 IntOP-02 Battery Using OP-02 SLA BatteryCharging the Battery 88lo8batOP-03 RS-232C Serial Interface InstallationRS-232C Specifications Ascii1100 Data Output ModeData Output Mode f-06-01 Data to be Sent f-06-02Example of f-06-02settings Connecting the AD-8121 Printer / Mode 1 or ModePrint Operations Settings Baud Rate f-06-04Command Mode Connecting the AD-8121 Printer / ModeAD-8121 Printout Sample Command List Acknowledgment and Error Codes‰ Weight Data Data Format‰ Unit Weight ‰ Store the specified F-Function setting value Using UFC Universal Flex Coms Function Store Text Data into the Scale MemoryExamples of PF command and AD-8121 Printout Sample Data Format for the Scale DataComparator Relay Output Circuit OP-04 InstallationMaximum rating of the Relay Output Specifications ModelGravity Acceleration MAP Values of gravity at various locationsWorld map Blank