A&D HC-3Ki, HC-15Ki Using UFC Universal Flex Coms Function, Store Text Data into the Scale Memory

Page 53

13-6. Using UFC (Universal Flex Coms) Function

‰The UFC function allows you to print out as you format the printer (UFC format).

‰The scale can store the UFC format as text data. It will include parameters to replace with the count data, weight data and so on.

‰The maximum number of text data is 384 characters.

‰Terminator for the “PF” command is "CR" or "CRLF".

‰Using “PF” command, the text data has to be sent to the scale from the computer in advance. Then, connect the scale with the printer.

‰When the PRINT key is pressed or by auto-print mode A/B, the scale will send the stored text data with the parameters replaced by the original data.

Store Text Data into the Scale Memory

Command

Reply

P

F

,

$

P

C

,

T

E

X

T

,

#

2

0

,

$

S

P

½

2

,

&

$

C

R

,

$

L

F

,

$

W

T

,

$

C

R

,

$

L

F

C

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ACK

C

LF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Terminator

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The “PF” command sends text data that will include:

‰Parameters for the scale data and control codes

Parameter

Data & Code

$PC

Count

$WT

Weight

$UW

Unit weight in use

$TR

Tare weight in use

$TL

Total count

$AN

Accumulation numbers

Parameter

Data & Code

$CD

ID number in use

$CP

Comparator result

$CM

Comma

$SP

Space

$CR

Carriage Return

$LF

Line Feed

These parameters must be used in capital letters.

‰ASCII text string

Text string is described in single quote marks as ‘Data’. The single quote itself is written as ’’(2 single quotes).

Example: Text ‘ABC’ is described as ‘’’ABC’’’.

‰The ASCII hexadecimal code

The ASCII hexadecimal codes are written in the form “#" + 2 hexadecimal digits. This will mainly be used to send control codes that can’t be described as a text string.

Example: #04

“EOT” of ASCII code

‰Repeat data

The control codes $SP, $CR and $LF can be used with “ + maximum 2 digit number”. That code will be repeated the number of times designated.

Example: $LF9 Repeat “$LF” 9 times.

$SP12 Put 12 “Spaces”.

‰Link mark “&”

If you will send more than 2 lines of data, attach “&” to the end of the first line. Then, the scale considers the data to be continued.

51

Image 53
Contents Counting Scale This manual and Marks Contents AWA Audible Weighing Assist Introduction FeaturesIntroduction Parts Overview UnpackingBest Conditions For Weighing Setting Up Your ScaleCalibration ON/OFFId-00 Total880000.880.00000 0000 Automatic Last Unit Weight Used888.8.888.0 Front Panel Overview Basic Operations Turn The Power on and OFF880000.8 Basic OperationsTare TareTo Start Counting 888.8.88.10 Unit Weight By a SampleAdd Add0280 Add 888.8.88.500000 Add 0112 Add 888.8.88.200000 Add Key 888.8.882.00000 0000 Lo ut Unit Weight By Keyboard888.8.8810 Reset Unit Weight By ID Number0000 Id-00 Id-12Using the Keyboard Tare Key Entering a Tare Weight888.8.881.0 0615888.8-554 888.8.-554To Clear Tare EitherId-00 Store Unit WeightStore Unit Weight by ID Numbers Clear Id-12 Clear Id-00Clear idall Clearing All ID Memories at OnceKey, the tare and/or comparator limits Unit Weight, Tare & Comparator Limits MemorizedAdding Using the M+ Key Using the M+ MemoryM+ Memory Function To Erase the Last M+ AdditionViewing the M+ Total Automatic M+ Accumulation ModeClearing the M+ Total M- Function8f-00810 8f-05810 88888100Comparator Function To Set the Comparator888.8.-102 888.8888.8.-198 Viewing Comparator Limits888Cal02 Calibration Procedure Using a Weight888Cal10 Calibration5000 Cal 5001Cal f 5000 5000Gravity Compensation 9800Function Parameters To Change or View F-Function Settings00-02 00-0101-01 01-0201-05 Acai Operation & Min. Unit Weight02-01 02-0203-02 03-0104-01 04-02Comparator 04-0505-01 05-02 05-04 05-05 06-03 06-01 06-0206-04 RS-232C Data Output09-01 06-0509-02 09-X Key88888821 88888828Acai Function Acai Automatic OperationPcs On Acai Manual OperationWeighing Pan Addition Range Stable AcaiOff Mode Setting To Enable/Disable AWA Function888.off02 AWA Function888.of150 888.of100Target IntUsing OP-02 SLA Battery OP-02 Battery88lo8bat Charging the BatteryRS-232C Specifications InstallationOP-03 RS-232C Serial Interface AsciiData Output Mode f-06-01 Data Output Mode1100 Data to be Sent f-06-02Print Operations Settings Connecting the AD-8121 Printer / Mode 1 or ModeExample of f-06-02settings Baud Rate f-06-04AD-8121 Printout Sample Connecting the AD-8121 Printer / ModeCommand Mode Acknowledgment and Error Codes Command ListData Format ‰ Weight Data‰ Unit Weight ‰ Store the specified F-Function setting value Store Text Data into the Scale Memory Using UFC Universal Flex Coms FunctionData Format for the Scale Data Examples of PF command and AD-8121 Printout SampleMaximum rating of the Relay Output OP-04 InstallationComparator Relay Output Circuit Model SpecificationsValues of gravity at various locations Gravity Acceleration MAPWorld map Blank