A&D HC-3Ki, HC-15Ki, HC-30Ki, HC-6Ki manual 00-01, 00-02, 01-01, 01-02, 01-04

Page 33

9-2. F-Functions

‰ “ ” designates Factory Settings.

F-00-X Weight Unit

USA Version ONLY

f-00-01

‰Weight Display when the scale is switched on. See also setting “f-09-01=2”.

0

kg (kilograms).

 

 

1

lb (pounds).

 

 

 

‰ Unit Weight (when “lb” is selected).

 

 

 

 

f-00-02

 

0

lb as piece weight.

 

 

 

1

lb as 1,000 piece weight.

 

 

 

F-01-X Operations

f-01-01

‰Operation Mode.

0

Normal Operation. All features and keys available.

 

 

1

Simplified Operation. The unit weight registration is by

sample only. All other keys are disabled.

 

f-01-02

‰“Add” Sample Request Override.

If the sample weight is too light and the scale asks to “Add” more sample pieces, using this F-Function, the unit weight can be entered without adding the requested sample pieces. Or disable the “Add” Sample Request function.

0

“Add” sample request function is disabled. Light unit weight

can be accepted without “Add” more sample request.

 

1

The unit weight can be entered without requested “Add”

sample pieces (via the

ENTER

key).

 

2

The unit weight cannot

be entered without requested “Add”

sample pieces (via the

ENTER

key).

 

‰“f-01-03” is for factory use and should be “0”.

f-01-04

‰Display ON Unit Weight – Reset or Last.

 

When the scale is switched on, the scale can be set to recall

 

the last unit weight used.

0

 

The unit weight is RESET (cleared) when display comes on.

 

 

 

1

 

The unit weight last used will be entered automatically.

31

Image 33
Contents Counting Scale This manual and Marks Contents AWA Audible Weighing Assist Features IntroductionIntroduction Parts Overview UnpackingBest Conditions For Weighing Setting Up Your ScaleCalibration ON/OFFTotal 880000.880.00000Id-00 Automatic Last Unit Weight Used 888.8.888.00000 Front Panel Overview Basic Operations Turn The Power on and OFF880000.8 Basic OperationsTare TareTo Start Counting 888.8.88.10 Unit Weight By a SampleAdd Add888.8.88.50 0000 Add0280 Add 888.8.88.20 0000 Add0112 Add 888.8.882.0 0000Key Unit Weight By Keyboard 888.8.88100000 Lo ut Reset Unit Weight By ID Number0000 Id-00 Id-12Using the Keyboard Tare Key Entering a Tare Weight888.8.881.0 0615888.8-554 888.8.-554To Clear Tare EitherStore Unit Weight Store Unit Weight by ID NumbersId-00 Clear Id-12 Clear Id-00Clear idall Clearing All ID Memories at OnceKey, the tare and/or comparator limits Unit Weight, Tare & Comparator Limits MemorizedAdding Using the M+ Key Using the M+ MemoryM+ Memory Function To Erase the Last M+ AdditionViewing the M+ Total Automatic M+ Accumulation ModeClearing the M+ Total M- Function8f-00810 8f-05810 88888100Comparator Function To Set the Comparator888.8.-102 888.8888.8.-198 Viewing Comparator Limits888Cal02 Calibration Procedure Using a Weight888Cal10 Calibration 5000 Cal 5001 Cal f 5000 5000Gravity Compensation 9800Function Parameters To Change or View F-Function Settings00-02 00-0101-01 01-0201-05 Acai Operation & Min. Unit Weight02-01 02-0203-02 03-0104-01 04-0204-05 05-01 05-02 05-04 05-05Comparator 06-03 06-01 06-0206-04 RS-232C Data Output09-01 06-0509-02 09-X Key88888821 88888828Acai Function Acai Automatic OperationPcs On Acai Manual OperationWeighing Pan Addition Range Stable AcaiOff Mode Setting To Enable/Disable AWA Function888.off02 AWA Function888.of150 888.of100Target IntUsing OP-02 SLA Battery OP-02 Battery88lo8bat Charging the BatteryRS-232C Specifications InstallationOP-03 RS-232C Serial Interface AsciiData Output Mode f-06-01 Data Output Mode1100 Data to be Sent f-06-02Print Operations Settings Connecting the AD-8121 Printer / Mode 1 or ModeExample of f-06-02settings Baud Rate f-06-04Connecting the AD-8121 Printer / Mode Command ModeAD-8121 Printout Sample Acknowledgment and Error Codes Command ListData Format ‰ Weight Data‰ Unit Weight ‰ Store the specified F-Function setting value Store Text Data into the Scale Memory Using UFC Universal Flex Coms FunctionData Format for the Scale Data Examples of PF command and AD-8121 Printout SampleOP-04 Installation Comparator Relay Output CircuitMaximum rating of the Relay Output Model SpecificationsValues of gravity at various locations Gravity Acceleration MAPWorld map Blank