Command List

Command

 

 

 

 

Definition

Notes

@

Start / stop continuous data transmission.

 

A

Same as

 

 

 

key.

Key command

RESET

 

 

 

 

 

 

 

 

 

 

D

Set a known tare weight.

“D,1.23CRLF” sets the tare

weight as "1.23kg".

 

 

 

 

 

 

 

 

 

E

Store the unit weight and other values in use to

Refer to the data format.

ID memory.

 

 

 

 

 

 

Refer f-01-05

 

 

 

 

 

 

 

F

Recall a unit weight from ID memory.

“F12CRLF” recalls from ID12.

G

Set a known unit weight.

“G,0.123CRLF” sets the unit

weight as "0.123g" (or "0.123 lb").

 

 

 

 

 

 

 

 

 

J

Same as the

 

 

 

 

 

key.

Key command

TOTAL

 

 

 

 

 

 

 

K

Same as the

 

key.

Key command

M+

 

 

 

 

 

Q

Send data immediately.

Data depends on f-06-02

S

Send stable data after accepting command.

 

T

Same as the

 

 

 

 

key.

Key command

TARE

 

 

 

 

X

Request a list of the F-Function parameters.

The last data terminates with

Y

Request a list of the ID memory contents.

<EOT> (04H)

Z

Same as the

 

 

 

 

key.

Key command

ZERO

 

 

 

ON

Start the scale from power on sequence

 

?ID

Send the ID number in use.

 

?QT

Send the pcs (count) data.

 

?WT

Send the weight data.

Refer to the data format for the

?UW

Send the unit weight in use.

reply.

?AQ

Send the total (accumulated) M+ memory count

 

d t

 

 

 

 

 

 

 

?AN

Send the number of additions to M+ memory.

 

?TR

Send the tare weight in use.

 

?MR

Send the specified ID memory contents.

 

MR

Store the unit weight and tare weight into the

 

specified ID memory.

Refer to the data format for the

 

 

 

reply.

ML

Store the comparator limits into the specified ID

memory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CM

Clear the specified ID memory contents

“CM,1.2CRLF” clears content of

id12.

 

 

 

 

 

 

 

 

 

?FC

Send the specified F-Function setting.

Refer to the data format for the

FC

Store the specified F-Function setting value.

reply.

Acknowledgment and Error Codes

When the scale receives an external command, it reacts as follows:

‰If the command requests a data reply, the scale will send the data.

For other commands, the scale will send an acknowledgment <ACK><CR><LF> or <ACK> (see F-Function “f-09-02”) upon acceptance of the command.

47

Image 49
Contents Counting Scale This manual and Marks Contents AWA Audible Weighing Assist Introduction FeaturesIntroduction Parts Overview UnpackingBest Conditions For Weighing Setting Up Your ScaleCalibration ON/OFF880000.880.00000 TotalId-00 888.8.888.0 Automatic Last Unit Weight Used0000 Front Panel Overview Basic Operations Turn The Power on and OFF880000.8 Basic OperationsTare TareTo Start Counting 888.8.88.10 Unit Weight By a SampleAdd Add0000 Add 888.8.88.500280 Add 0000 Add 888.8.88.200112 Add 0000 888.8.882.0Key 888.8.8810 Unit Weight By Keyboard0000 Lo ut Reset Unit Weight By ID Number0000 Id-00 Id-12Using the Keyboard Tare Key Entering a Tare Weight888.8.881.0 0615888.8-554 888.8.-554To Clear Tare EitherStore Unit Weight by ID Numbers Store Unit WeightId-00 Clear Id-12 Clear Id-00Clear idall Clearing All ID Memories at OnceKey, the tare and/or comparator limits Unit Weight, Tare & Comparator Limits MemorizedAdding Using the M+ Key Using the M+ MemoryM+ Memory Function To Erase the Last M+ AdditionViewing the M+ Total Automatic M+ Accumulation ModeClearing the M+ Total M- Function8f-00810 8f-05810 88888100Comparator Function To Set the Comparator888.8.-102 888.8888.8.-198 Viewing Comparator Limits888Cal02 Calibration Procedure Using a Weight888Cal10 Calibration5000 Cal 5001Cal f 5000 5000Gravity Compensation 9800Function Parameters To Change or View F-Function Settings00-02 00-0101-01 01-0201-05 Acai Operation & Min. Unit Weight02-01 02-0203-02 03-0104-01 04-0205-01 05-02 05-04 05-05 04-05Comparator 06-03 06-01 06-0206-04 RS-232C Data Output09-01 06-0509-02 09-X Key88888821 88888828Acai Function Acai Automatic OperationPcs On Acai Manual OperationWeighing Pan Addition Range Stable AcaiOff Mode Setting To Enable/Disable AWA Function888.off02 AWA Function888.of150 888.of100Target IntUsing OP-02 SLA Battery OP-02 Battery88lo8bat Charging the BatteryRS-232C Specifications InstallationOP-03 RS-232C Serial Interface AsciiData Output Mode f-06-01 Data Output Mode1100 Data to be Sent f-06-02Print Operations Settings Connecting the AD-8121 Printer / Mode 1 or ModeExample of f-06-02settings Baud Rate f-06-04Command Mode Connecting the AD-8121 Printer / ModeAD-8121 Printout Sample Acknowledgment and Error Codes Command ListData Format ‰ Weight Data‰ Unit Weight ‰ Store the specified F-Function setting value Store Text Data into the Scale Memory Using UFC Universal Flex Coms FunctionData Format for the Scale Data Examples of PF command and AD-8121 Printout SampleComparator Relay Output Circuit OP-04 InstallationMaximum rating of the Relay Output Model SpecificationsValues of gravity at various locations Gravity Acceleration MAPWorld map Blank