A&D EJ-440, EJ-6100, EJ-3000, EJ-200, EJ-4100 This manual and Marks, Compliance with FCC rules

Page 2

This manual and Marks

All safety messages are identified by the following, “WARNING” or “CAUTION”, of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows:

WARNING

A potentially hazardous situation which, if not avoided, could result

in death or serious injury.

 

CAUTION

A potentially hazardous situation which, if not avoided, may result in

minor or moderate injury.

 

This is a hazard alert mark.

Note This manual is subject to change without notice at any time to improve the product. No part of this manual may be photocopied, reproduced, or translated into another language without the prior written consent of the A&D Company.

Product specifications are subject to change without any obligation on the part of the manufacture.

Compliance with FCC rules

Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when this equipment is operated in a commercial environment. If this unit is operated in a residential area it might cause some interference and under these circumstances the user would be required to take, at his own expense, whatever measures are necessary to eliminate the interference. (FCC = Federal Communications Commission in the U.S.A.)

Copyright2009

Image 2
Contents 1WMPD4001917 This manual and Marks Compliance with FCC rulesContents Maintenance Introduction UnpackingNET indicator Part Names and FunctionsPower source Setting UPSetting up your balance Storage Installing batteriesBreeze break LCD backlight Turn the power on and OFFOperation Units Conversion tableBasic operation NETSelecting a weighing unit Counting mode using the Acai function Counting mode pcsSelecting the counting mode Storing the sample unit100 0 % Percent mode %100 1000. %Comparator Setting exampleSelecting a comparison mode FuncCp lo 000000 Cp Hi 000000001234 001230Cal Calibration using a weightCalibration 060000Cal 50000 GlpCal 97985 Gravity acceleration correctionCp Hi Entering the function setting modeFunctions Key operationEnd Cp Hi Func PoffACai Storing weighing units UnitEnd id Function list Smpl Func ACaiUmin LdinEJ-02 USB Interface EJ-03 InstallationOptions EJ-03 RS-232C serial interfaceInterface specifications EIA RS-232CData output mode Data formatCommand mode Command listEJ-11 Breeze break EJ-07 / EJ-08 InstallationEJ-07 / EJ-08 Underhook EJ-12 Carrying caseDensity specific gravity measurement EJ-13 InstallationEJ-13 Density Determination Kit Example of density measurement 000Change the function table 2000 1751 8801End id func Setting the ID numberID Number and GLP Display character setData format for calibration test report Output exampleData format for calibration report End Block Calibration test using a weightTitle Title block and End block20000 20000 EndOverload error MaintenanceError codes Range over notice Unit weight error Sample quantity noticeLb0 Hb0 Error1Cal e -Cal e Hb1 Lb1Specifications EJ seriesOther weighing units Dimensions OptionsGravity Acceleration MAP Values of gravity at various locationsWorld map