Multi-Tech Systems MVP103, 410 manual Auto Disconnect, Automatic

Page 41

Chapter 3 – Related MultiVOIP Setup Parameters

Voice/Fax Parameter Definitions (cont’d)

Field Name

 

Values

Description

 

 

 

 

Dynamic Jitter (cont’d)

 

 

 

 

 

Minimum

 

60 to 400 ms

The minimum dynamic jitter buffer of 60 milliseconds is

Jitter Value

 

 

the minimum delay that would be acceptable over a low

 

 

 

jitter network.

 

 

 

Default = 150 msec

 

 

 

 

Maximum

 

60 to 400 ms

The maximum dynamic jitter buffer of 400 milliseconds is

Jitter Value

 

 

the maximum delay tolerable over a high jitter network.

 

 

 

Default = 300 msec

 

 

 

 

Optimization

 

0 to 12

The Optimization Factor determines how quickly the

Factor

 

 

length of the Dynamic Jitter Buffer is changed based on

 

 

 

actural jitter encountered on the network. Selecting the

 

 

 

minimum value of 0 means low voice delay is desired,

 

 

 

but increases the possibility of jitter induced voice quality

 

 

 

problems. Selecting the maximum value of 12 means

 

 

 

highest voice qauality under jitter conditions is desired at

 

 

 

the cost of increased voice delay.

 

 

 

Default = 7.

 

 

 

Auto

Disconnect

 

 

 

 

Automatic

 

--

The Automatic Disconnection group provides four

Disconnect-

 

 

options which can be used singly or in any combination.

ion

 

 

 

 

 

 

 

Jitter Value

 

1-65535

The Jitter Value defines the average inter-arrival packet

 

 

milli-seconds

deviation (in milliseconds) before the call is automatically

 

 

 

disconnected. The default is 300 milliseconds. A higher

 

 

 

value means voice transmission will be more accepting of

 

 

 

jitter. A lower value is less tolerant of jitter.

 

 

 

Inactive by default. When active, default = 300 ms.

 

 

 

However, value must equal or exceed Dynamic

 

 

 

Minimum Jitter Value.

 

 

 

 

Call Duration

 

1-65535 seconds

Call Duration defines the maximum length of time (in

 

 

 

seconds) that a call remains connected before the call is

 

 

 

automatically disconnected.

 

 

 

Inactive by default.

 

 

 

When active, default = 180 sec.

 

 

 

This may be too short for most configurations, requiring

 

 

 

upward adjustment.

 

 

 

 

Consecutive

 

1-65535

Consecutive Packets Lost defines the number of

Packets Lost

 

 

consecutive packets that are lost after which the call is

 

 

 

automatically disconnected.

 

 

 

Inactive by default.

 

 

 

When active, default = 30

 

 

 

 

Network

 

1 to 65535 seconds;

Specifies how long to wait before disconnecting the call

Discon-

 

Default = 30 sec.

when IP network connectivity with the remote site has

nection

 

 

been lost.

 

 

 

 

Multi-Tech Systems, Inc. Avaya Communication Manager Guide

41

Image 41
Contents MultiVOIP Revision Date Description Configuration GuideContents Introduction IntroductionMultiVOIP in Avaya Communication Manager System Configuration ConfigurationChannel RTP Port Rtcp Port T38 Port Configuration Configuration Bandwidth per Channel Voice Frames per IP Packet Communication Manager MultiVOIP FXS Channels Configuration Configuration Communication Manager MultiVOIP FXO Channels Configuration = Isdn Communication Manager MultiVOIP did Channels Configuration = Isdn Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Configuration Regional Parameter Definitions Field Name Values Description Regional Parameters screenField Name Values Description Regional Parameter DefinitionsTone Pair Values Related MultiVOIP Setup Parameters Communication Manager SettingsRelated MultiVOIP Setup Parameters Version 4 Parameters Voice/Fax Parameters Channel to be configured is selected here Fax Volume Fax EnableJitter Value Default = Mode Fax FRF 11 T.38Advanced Features Jitter Automatic Auto DisconnectInterface Parameters Related MultiVOIP Setup Parameters FXS Not applicable to FXS interface Dialing Options FXO Interface Parameter DefinitionsFXO Disconnect On cont’d CID Number Voip Caller ID Case #4 Remote FXS call on H.323 voip system Did Options GK General Settings Definitions GK General SettingsActivity Configuration PolicyRAS Parameters GK General Settings Definitions cont’dGatekeeper Endpoints Command Buttons Current Calls Field Definitions Gatekeeper CallsNumber. a sequential number for identification in the list ID alias of the endpoint originating the callConference ID number CID is a unique non-zero value created Call Details Field DefinitionsConference will have the same CID ID identifies the call with which the message is associatedType of conference request create, invite or join Total amount of bandwidth used by the callLast reported state of the call Reason associated with the last state of the callE164 alias phone number used to make the call H.323 alias name used to make the callAn e-mail address used to make the call Address and port numberNetwork Parameter Definitions Gatekeeper Network ParametersField Name Values Description Status Information OptionsLine Hunting Information ARQCall Mode GK-ID Services Screen Definitions Gatekeeper ServicesField Name Values Description GK Defined Services PublicDynamic Miscellaneous MiscellaneousComm Mgr Dialing Example #1 a local station-to-station call Remote Configuration Miscellaneous MVP130-AV Rev a MVP130-AV RevMVP130-AV-FXS Rev a MVP210-AV Rev aMiscellaneous Link Management Feature Issues Index IndexCoder field FRF11 Gatekeeper Response to field GK General Settings, RAS DID-DPO FXO Trunk Group form fields to set Dtmf Gain Unregister endpoints command Dtmf Gain High Tones