Lincoln Electric IM915 manual Safety

Page 2

i

SAFETY

 

i

WARNING

CALIFORNIA PROPOSITION 65 WARNINGS

Diesel engine exhaust and some of its constituents are known to the State of California to cause can- cer, birth defects, and other reproductive harm.

The Above For Diesel Engines

The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.

The Above For Gasoline Engines

ARC WELDING CAN bE HAzARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIbLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR bEFORE OPERATING.

Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box 351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.

bE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE PERFORMED ONLY bY QUALIFIED INDIVIDUALS.

FOR ENGINE powered equipment.

1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.

____________________________________________________

1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.

____________________________________________________

1.c. Do not add the fuel near an open flame welding arc or when the engine is running.

Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporiz- ing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.

____________________________________________________

1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.

____________________________________________________

1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete. Always use the greatest care when working near moving parts.

___________________________________________________

1.f. Do not put your hands near the engine fan. Do not attempt to override the governor or idler by pushing on the throttle control rods

while the engine is running.

___________________________________________________

1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.

1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.

ELECTRIC AND MAGNETIC FIELDS may be dangerous

2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines

2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.

2.c. Exposure to EMF fields in welding may have other health effects which are now not known.

2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:

2.d.1. Route the electrode and work cables together - Secure them with tape when possible.

2.d.2. Never coil the electrode lead around your body.

2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.

2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.

2.d.5. Do not work next to welding power source.

Image 2
Contents Power Feed 10M Single Wire Feeder July Safety Depends on YouSafety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Thank You TAbLE of Contents Vii Power Feed 10M Single Wire Feeder SPEC.# Type Input PowerTemperature Rating Welding Capacity RatingMounting Electric Shock can killLocation Weld CAbLE SIzINGElectrode Work Power SourceCOAxIAL Weld CAbLES DIP Switch #7 Position Polarity Negative Electrode PolarityPower Source Pin Function Welding Gun/Wire Feeder Trigger ConnectorWire Feeder Wire Feeder Pin FunctionChanging Drive Rolls and Wire Guides DescriptionDrive Roll Pressure Setting Changing the GUN Receiver bUSHINGMagnum GUN and CAbLE ASSEMbLIES Welding GUNS, Torches and ACCES- SoriesGUN Receiver bUSHING To change the gear ratio Wire Feed Shut Down CircuitChanging the Gear Ratio Spindle Placement Wire Reel LoadingDIP Switch #8 Position Gear Ratio Loading 16 to 44 lb .3 20kg SpoolsUsing K1504-1 Coil Reel Figure A.10Removing a Readi-Reel Weld Wire RoutingLoading 30 lb .6 kg Readi-Reels See Figure A.11 BUILDUP OF SHIELDING GAS may harm health or kill Shielding GAS ConnectionCylinder may explode if damaged ExAMPLES of Connecting AN Arclink Power Wave System ARC Rays can burn Fumes and Gases can be dangerousWelding Sparks can cause fire or explosion Common Welding AbbREVIATIONSRequired Equipment Product DescriptionRecommended Processes Additional Required EquipmentCV Welding Pulse Welding or STT Welding Front Panel Controls and Connections Status LED Synergic CV Voltage Display Volts / Trim DisplayPrior to Welding LAYOUT-CONTROLS see Figure b.3 Mode Select Panel 4 MSP4Overview LAYOUT-DIGITAL DisplayChanging ARC Wave Control POWER-UP SequenceChanging Weld Modes Infrared IR ControlAccessing the Machine Setup Menu Limit SettingMachine SETUP/USER Preferences SET-UP Features Menu Figure b.3a Setup MenuUser Defined Parameters Parameter Definition Procedure Change Method Stall Factor AdjustmentReset Consumable Weight Parameter Definition Gun Offset AdjustmentCrater Delay TIG Gas ControlDisplay Trim as Volts Option Arc Start/Loss Error TimeParameter Definition Push-Pull Gun Knob behavior Sense From StudsParameter Definition Show Test Modes 100 View Diagnostics107 View Power Source Protocol 102 View Fatal Logs505 Setup Menu Lock 503 Memory button Disable504 Mode Select Panel Lock Parameter Definition 501 Encoder Lockout509 UI Master Lockout Only be accessed using Power Wave Manager softwareParameter Definition 506 Set User Interface Passcode Step Trigger Operation Cold Feed / GAS Purge SwitchStep / 4-STEP Trigger Switch Step Trigger Operation Sequence of OperationFigure b.5 Modes Process Setup and OperationNon- Synergic Steel and Stainless Synergic GMAW-P Pulsed MIG Welding ARC ControlPulse-on-Pulse Welding Machine Functionality bY Weld Process CC Stick ModesCV GMAW/FCAW NON-SYNERGIC Output Control KNObS, Weld Mode 5Process Weld Mode CV NON-SYNERGIC ModesSynergic CV Modes Wire SIzE 030 035 045 052Gmaw Synergic Material Process GASPulse and PULSE-0N-PULSE Modes Wire SIzEPulse and PULSE-ON-PULSE Synergic WIR E S IZE MAW-S TT WE L D ModeSTT and STT II NONN-SYNERGIC 035 045 052Touch Start TIG Gtaw TIG WeldingGtaw Touch Start TIG Welding All Metals Touch Start TIGUser Memories Weld Mode SearchingSearching for a Weld Mode Limit Setting Enable Accessories OptionalAccessories Lb. coils to 2 spindles Periodic Maintenance Safety PrecautionsRoutine Maintenance CALIbRATION SpecificationTROUbLESHOOTING POSSIbLE PRObLEMSSymptoms Cause Recommended Course of ActionArclink System Error Codes Your local Lincoln Authorized Output PRObLEMS TROUbLESHOOTING PRObLEMS POSSIbLE Power Feed 10M Single Wire Feeder14.56 18.48 15.80 30.46Power Feed 10M Single Wire Feeder Power Feed 10M Single Wire Feeder Precaucion Warnung