OUTPUT PRObLEMS

The feeder does power up - no dis-

1.

The Power Wave power source is

 

play, no cold feed.

 

OFF. Turn ON the Power Wave

 

 

 

power source.

 

 

2.

The circuit breaker for the wire

 

 

 

feeder on power source have

 

 

 

tripped. Reset the circuit break-

 

 

 

ers.

 

 

3.

The control cable may be loose

 

 

 

or damaged. Tighten, repair or

 

 

 

replace the control cable.

 

 

 

 

No shielding gas.

1. The gas supply is OFF or empty.

 

 

 

Verify the gas supply is ON and

 

 

 

flowing.

 

 

2.

The gas hose is cut or crushed.

 

 

 

Route the gas hose so it avoids

 

 

 

sharp corners and make sure

 

 

 

nothing is on top of it. Repair or

 

 

 

replace damaged hoses.

 

 

3.

Dirt or debris is in the solenoid.

 

 

 

Apply filtered shop at 80psi to the

 

 

 

solenoid to remove dirt.

 

 

4.

There is a loose solenoid connec-

 

 

 

tion. Remove the cover and

 

 

 

check that all connections are in

 

 

 

good condition.

 

 

5.

The solenoid has failed.

 

 

 

 

Gas solenoid not operating properly

1. Inlet gas pressure exceeding 80

 

or intermittent.

 

psi(5.5 bar). Verify that gas pres-

 

 

 

sure regulator is operating prop-

 

 

 

erly.

 

 

 

 

 

 

 

 

 

If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized Field Service Facility.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER FEED™ 10M SINGLE WIRE FEEDER

Image 63
Contents Safety Depends on You Power Feed 10M Single Wire Feeder JulySafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté Thank You TAbLE of Contents Vii Welding Capacity Rating SPEC.# Type Input PowerTemperature Rating Power Feed 10M Single Wire FeederWeld CAbLE SIzING Electric Shock can killLocation MountingPower Source COAxIAL Weld CAbLESElectrode Work Negative Electrode Polarity DIP Switch #7 Position PolarityWire Feeder Pin Function Welding Gun/Wire Feeder Trigger ConnectorWire Feeder Power Source Pin FunctionDescription Changing Drive Rolls and Wire GuidesChanging the GUN Receiver bUSHING Drive Roll Pressure SettingWelding GUNS, Torches and ACCES- Sories GUN Receiver bUSHINGMagnum GUN and CAbLE ASSEMbLIES Wire Feed Shut Down Circuit Changing the Gear RatioTo change the gear ratio Loading 16 to 44 lb .3 20kg Spools Wire Reel LoadingDIP Switch #8 Position Gear Ratio Spindle PlacementFigure A.10 Using K1504-1 Coil ReelWeld Wire Routing Loading 30 lb .6 kg Readi-Reels See Figure A.11Removing a Readi-Reel Shielding GAS Connection Cylinder may explode if damagedBUILDUP OF SHIELDING GAS may harm health or kill ExAMPLES of Connecting AN Arclink Power Wave System Common Welding AbbREVIATIONS Fumes and Gases can be dangerousWelding Sparks can cause fire or explosion ARC Rays can burnAdditional Required Equipment Product DescriptionRecommended Processes Required EquipmentCV Welding Pulse Welding or STT Welding Front Panel Controls and Connections Status LED Volts / Trim Display Prior to WeldingSynergic CV Voltage Display LAYOUT-DIGITAL Display Mode Select Panel 4 MSP4Overview LAYOUT-CONTROLS see Figure b.3Infrared IR Control POWER-UP SequenceChanging Weld Modes Changing ARC Wave ControlLimit Setting Machine SETUP/USER PreferencesAccessing the Machine Setup Menu Figure b.3a Setup Menu SET-UP Features MenuUser Defined Parameters Stall Factor Adjustment Parameter Definition Procedure Change MethodTIG Gas Control Parameter Definition Gun Offset AdjustmentCrater Delay Reset Consumable WeightSense From Studs Arc Start/Loss Error TimeParameter Definition Push-Pull Gun Knob behavior Display Trim as Volts Option102 View Fatal Logs 100 View Diagnostics107 View Power Source Protocol Parameter Definition Show Test ModesParameter Definition 501 Encoder Lockout 503 Memory button Disable504 Mode Select Panel Lock 505 Setup Menu LockOnly be accessed using Power Wave Manager software Parameter Definition 506 Set User Interface Passcode509 UI Master Lockout Cold Feed / GAS Purge Switch Step / 4-STEP Trigger SwitchStep Trigger Operation Sequence of Operation Step Trigger OperationFigure b.5 Process Setup and Operation Non- SynergicModes ARC Control Steel and Stainless Synergic GMAW-P Pulsed MIG WeldingPulse-on-Pulse Welding CC Stick Modes Machine Functionality bY Weld ProcessCV NON-SYNERGIC Modes Output Control KNObS, Weld Mode 5Process Weld Mode CV GMAW/FCAW NON-SYNERGICMaterial Process GAS Wire SIzE 030 035 045 052Gmaw Synergic Synergic CV ModesWire SIzE Pulse and PULSE-ON-PULSE SynergicPulse and PULSE-0N-PULSE Modes 035 045 052 MAW-S TT WE L D ModeSTT and STT II NONN-SYNERGIC WIR E S IZEAll Metals Touch Start TIG Gtaw TIG WeldingGtaw Touch Start TIG Welding Touch Start TIGWeld Mode Searching Searching for a Weld ModeUser Memories Limit Setting Enable Optional AccessoriesAccessories Lb. coils to 2 spindles CALIbRATION Specification Safety PrecautionsRoutine Maintenance Periodic MaintenanceTROUbLESHOOTING Cause Recommended Course of Action PRObLEMSSymptoms POSSIbLEArclink System Error Codes Your local Lincoln Authorized Output PRObLEMS TROUbLESHOOTING PRObLEMS POSSIbLE Feeder Power Feed 10M Single Wire30.46 14.56 18.48 15.80Power Feed 10M Single Wire Feeder Power Feed 10M Single Wire Feeder Precaucion Warnung