Lincoln Electric IM915 Parameter Definition Show Test Modes, View Diagnostics, View Fatal Logs

Page 37

 

b-15

 

OPERATION

b-15

 

 

 

 

 

 

 

 

 

 

 

USER DEFINED PARAMETERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

Definition

 

 

 

 

P.99

Show Test Modes

 

 

 

 

 

 

Most power sources contain weld modes used for calibration and test purposes. By default, the machine

 

 

 

 

 

does not include test weld modes in the list of weld modes that are available to the operator. To manually

 

 

 

 

 

select a test weld mode, set this option to "Yes". When the power source is turned off and back on again,

 

 

 

 

 

the test modes will no longer appear in the mode list. Test weld modes typically require the machine out-

 

 

 

 

 

put to be connected to a grid load and cannot be used for welding.

 

 

 

 

 

 

 

 

 

 

P.100

View Diagnostics

 

 

 

 

 

 

Diagnostics are only used for servicing or troubleshooting the Power Wave system.

 

 

 

 

 

Select "Yes" to access the diagnostic options in the menu. Additional parameters will

 

 

 

 

 

now appear in the setup menu (P.101, P.102, etc).

 

 

 

 

 

 

 

 

 

 

P.101

View Event Logs

 

 

 

 

 

 

Used for viewing all the system event logs. Press the Right Button to enter the option. Rotate Control

 

 

 

 

 

Knob to select the desired event log to read. Press the Right Button again to enter the selected log.

 

 

 

 

 

Rotating the Control Knob will scroll through the event log, displaying the log index number, event code

 

 

 

 

 

and some other data. Press the Left Button to back out to select another log. Press the Left Button again

 

 

 

 

 

to exit this option.

 

 

 

 

 

 

 

 

 

 

P.102

View Fatal Logs

 

 

 

 

 

 

Used for viewing all the system fatal logs. Press the Right Button to enter the option. Rotate Control Knob

 

 

 

 

 

to select the desired fatal log to read. Press the Right Button again to enter that log. Rotating the Control

 

 

 

 

 

Knob will scroll through the log, displaying the log index number and fatal code. Press the Left Button to

 

 

 

 

 

back out to select another log. Press the Left Button again to exit this option.

 

 

 

 

 

 

 

 

 

 

P.103

View Software Version Information

 

 

 

 

 

 

Used for viewing the software versions for each board in the system. Press the Right Button to

 

 

 

 

 

enter the option. Rotate Control Knob to select the desired board to read. Press the Right

 

 

 

 

 

Button again to read the firmware version. Press the Left Button to back out to select another

 

 

 

 

 

board. Rotate the Control Knob to select another board, or press the Left Button to exit this

 

 

 

 

 

option.

 

 

 

 

 

 

 

 

 

 

P.104

View Hardware Version Information

 

 

 

 

 

 

Used for viewing the hardware version for each board in the system. Press the right MSP

 

 

 

 

 

Button to enter the option. Rotate Set knob to select the desired board to read. Press the right

 

 

 

 

 

button again to read the hardware version. Press the left button to back out to select another

 

 

 

 

 

board. Press the left button again to exit this option.

 

 

 

 

 

 

 

 

 

 

P.105

View Welding Software Information

 

 

 

 

 

 

Used for viewing the Weld Set in the Power Source. Press the Right Button to read the Weld

 

 

 

 

 

Set version. Press the Left Button to back out and exit this option.

 

 

 

 

 

 

 

 

 

 

P.106

View Ethernet IP Address

 

 

 

 

 

 

Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to

 

 

 

 

 

read the IP Address. Press the Left Button to back out and exit this option. The IP address can-

 

 

 

 

 

not be changed using this option.

 

 

 

 

 

 

 

 

 

 

P.107

View Power Source Protocol

 

 

 

 

 

 

Used for viewing the type of power source the feeder is connected to. Press the Right Button to

 

 

 

 

 

identify the power source as either LincNet or ArcLink. Press the Left Button to back out and

 

 

 

 

 

exit this option.

 

 

 

 

 

 

 

 

 

POWER FEED™ 10M SINGLE WIRE FEEDER

Image 37
Contents Safety Depends on You Power Feed 10M Single Wire Feeder JulySafety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPrécautions DE Sûreté Thank You TAbLE of Contents Vii Temperature Rating SPEC.# Type Input PowerPower Feed 10M Single Wire Feeder Welding Capacity RatingLocation Electric Shock can killMounting Weld CAbLE SIzINGCOAxIAL Weld CAbLES Power SourceElectrode Work Negative Electrode Polarity DIP Switch #7 Position PolarityWire Feeder Welding Gun/Wire Feeder Trigger ConnectorPower Source Pin Function Wire Feeder Pin FunctionDescription Changing Drive Rolls and Wire GuidesChanging the GUN Receiver bUSHING Drive Roll Pressure SettingGUN Receiver bUSHING Welding GUNS, Torches and ACCES- SoriesMagnum GUN and CAbLE ASSEMbLIES Changing the Gear Ratio Wire Feed Shut Down CircuitTo change the gear ratio DIP Switch #8 Position Gear Ratio Wire Reel LoadingSpindle Placement Loading 16 to 44 lb .3 20kg SpoolsFigure A.10 Using K1504-1 Coil ReelLoading 30 lb .6 kg Readi-Reels See Figure A.11 Weld Wire RoutingRemoving a Readi-Reel Cylinder may explode if damaged Shielding GAS ConnectionBUILDUP OF SHIELDING GAS may harm health or kill ExAMPLES of Connecting AN Arclink Power Wave System Welding Sparks can cause fire or explosion Fumes and Gases can be dangerousARC Rays can burn Common Welding AbbREVIATIONSRecommended Processes Product DescriptionRequired Equipment Additional Required EquipmentCV Welding Pulse Welding or STT Welding Front Panel Controls and Connections Status LED Prior to Welding Volts / Trim DisplaySynergic CV Voltage Display Overview Mode Select Panel 4 MSP4LAYOUT-CONTROLS see Figure b.3 LAYOUT-DIGITAL DisplayChanging Weld Modes POWER-UP SequenceChanging ARC Wave Control Infrared IR ControlMachine SETUP/USER Preferences Limit SettingAccessing the Machine Setup Menu Figure b.3a Setup Menu SET-UP Features MenuUser Defined Parameters Stall Factor Adjustment Parameter Definition Procedure Change MethodCrater Delay Parameter Definition Gun Offset AdjustmentReset Consumable Weight TIG Gas ControlParameter Definition Push-Pull Gun Knob behavior Arc Start/Loss Error TimeDisplay Trim as Volts Option Sense From Studs107 View Power Source Protocol 100 View DiagnosticsParameter Definition Show Test Modes 102 View Fatal Logs504 Mode Select Panel Lock 503 Memory button Disable505 Setup Menu Lock Parameter Definition 501 Encoder LockoutParameter Definition 506 Set User Interface Passcode Only be accessed using Power Wave Manager software509 UI Master Lockout Step / 4-STEP Trigger Switch Cold Feed / GAS Purge SwitchStep Trigger Operation Sequence of Operation Step Trigger OperationFigure b.5 Non- Synergic Process Setup and OperationModes ARC Control Steel and Stainless Synergic GMAW-P Pulsed MIG WeldingPulse-on-Pulse Welding CC Stick Modes Machine Functionality bY Weld ProcessProcess Weld Mode Output Control KNObS, Weld Mode 5CV GMAW/FCAW NON-SYNERGIC CV NON-SYNERGIC ModesGmaw Synergic Wire SIzE 030 035 045 052Synergic CV Modes Material Process GASPulse and PULSE-ON-PULSE Synergic Wire SIzEPulse and PULSE-0N-PULSE Modes STT and STT II NONN-SYNERGIC MAW-S TT WE L D ModeWIR E S IZE 035 045 052Gtaw Touch Start TIG Welding Gtaw TIG WeldingTouch Start TIG All Metals Touch Start TIGSearching for a Weld Mode Weld Mode SearchingUser Memories Limit Setting Enable Optional AccessoriesAccessories Lb. coils to 2 spindles Routine Maintenance Safety PrecautionsPeriodic Maintenance CALIbRATION SpecificationTROUbLESHOOTING Symptoms PRObLEMSPOSSIbLE Cause Recommended Course of ActionArclink System Error Codes Your local Lincoln Authorized Output PRObLEMS TROUbLESHOOTING PRObLEMS POSSIbLE Feeder Power Feed 10M Single Wire30.46 14.56 18.48 15.80Power Feed 10M Single Wire Feeder Power Feed 10M Single Wire Feeder Precaucion Warnung