ARCLINK SYSTEM ERROR CODES
Err 33 | Capacitor bank "B" under | 1. | The power source input power |
| voltage. |
| may be wired incorrectly. Verify |
|
|
| the power source reconnect |
|
|
| panel wiring matches the input |
|
|
| power. |
|
| 2. | See the power source Instruction |
|
|
| Manual. |
|
|
|
|
Err 34 | Capacitor bank "A" overvolt- | 1. | The power source input power |
| age. |
| may be wired incorrectly. Verify |
|
|
| the power source reconnect |
|
|
| panel wiring matches the input |
|
|
| power. |
|
| 2. | See the power source Instruction |
|
|
| Manual. |
|
|
|
|
Err 35 | Capacitor bank "B" overvolt- | 1. | The power source input power |
| age. |
| may be wired incorrectly. Verify |
|
|
| the power source reconnect |
|
|
| panel wiring matches the input |
|
|
| power. |
|
| 2. | See the power source Instruction |
|
|
| Manual. |
|
|
|
|
Err 41 | Long term secondary over- | 1. | The power source has exceeded |
| current. |
| the output current limits. Adjust |
|
|
| the welding procedure to reduce |
|
|
| the current draw. The welding |
|
|
| procedure may exceed the |
|
|
| capacity of the power source. |
|
| 2. | See the power source Instruction |
|
|
| Manual. |
|
|
|
|
Err 43 | Capacitors are out of bal- | 1. | Verify the power source recon- |
| ance |
| nect panel wiring matches the |
|
|
| input power. |
|
| 2. | See the power source Instruction |
|
|
| Manual. |
|
|
|
|
|
|
|
|
If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.