Friedrich YS09 Make sure the wiring is adequate for your unit, Do not use an extension cord

Page 3

920-198-01

WARNING: Before operating your unit

Make sure the wiring is adequate for your unit.

If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in Figure 1.

DO NOT use an extension cord.

The cord provided will carry the proper amount of electrical power to the unit; an extension cord will not.

Make sure that the receptacle is compatible with the air conditioner cord plug provided.

This insures proper grounding. If you have a two prong receptacle you will need to have it replaced with a grounded receptacle by a certified electrician. The grounded receptacle should meet all national and local codes and ordinances. Under no circumstances should you remove the ground prong from the plug. You must use the three prong plug furnished with the air conditioner.

Test the power cord

All Friedrich room air conditioners are shipped from the factory with a Leakage Current Detection Interrupter (LCDI) equipped power cord. The LCDI device meets the UL and NEC requirements for cord connected air conditioners.

To test your power supply cord:

1.Plug power supply cord into a grounded 3 prong outlet.

2.Press RESET (See Figure 2).

3.Press TEST (listen for click; Reset button trips and pops out).

4.Press and release RESET (listen for click; Reset button latches and remains in). The power supply cord is ready for operation.

NOTE: LCDI device is not intended to be used as a switch.

Once plugged in the unit will operate normally without the need to reset the LCDI device.

If the device fails to trip when tested or if the power supply cord is damaged it must be replaced with a new supply cord from the manufac- turer. We recommend you contact our Technical Assistance Line at

(800)541-6645 ext. 845. To expedite service, please have your model and serial number available.

WARNING

Electrical Shock Hazard

Make sure your electrical receptacle has the same configuration as your air conditioner’s plug. If different, consult a Licensed Electrician.

Do not use plug adapters.

Do not use an extension cord.

Do not remove ground prong.

Always plug into a grounded 3 prong outlet. Failure to follow these instructions can result in death, fire, or electrical shock.

 

CIRCUIT RATING

REQUIRED WALL

 

OR TIME DELAY

MODEL

FUSE

RECEPTACLE

 

 

 

AMP

VOLT

NEMA

 

 

NO.

 

 

 

 

 

SS08 • SS10 • SS12 • SS14

15

125

5-15R

 

KS12 • KS15 • YS09

 

 

 

 

 

 

 

 

 

 

SS12 • SS16 • SM18

15

250

6-15R

 

SM21 • KM18

 

 

 

 

 

 

 

 

 

 

SM24 • SL28 • KM24

20

250

6-20R

 

YS13 • ES12 • ES16

 

 

 

 

 

 

 

 

 

 

SL36 • YM18 • YL24

30

250

6-30R

 

EM18 • EM24 • EL36

 

 

 

 

 

 

 

 

 

 

Figure 1

NOTE: Your LCDI device will resemble one of these illustrations.

RESET

TEST

RESET

WARNING

TEST BEFORE EACH USE

1. PRESS RESET BUTTON

2. PLUG LDCI INTO POWERTEST RECEPTACLE

3.PRESS TEST BUTTON,

RESET BUTTON SHOULD

POP UP

4.PRESS TEST BUTTON, FOR USE

DO NOT USE IF ABOVE TEST

FAILS

WHEN GREEN LIGHT IS ON

IT IS WORKING PROPERLY

Figure 2

For the best cooling performance and highest energy efficiency

Keep the filter clean

Make sure that your air conditioner is always in top performing condition by cleaning the filter regularly. Instructions for removing and cleaning the filter can be found on page 7.

Insulation

Good insulation will be a big help in maintaining desirable comfort levels. Doors should have weather stripping. Be sure to caulk around doors and windows.

Provide good air flow

Make sure the airflow to and from the unit is clear. Your air conditioner puts the conditioned air out at the top of the unit, and takes in unconditioned air at the bottom. Airflow is critical to good operation. It is just as important on the outside of the building that the airflow around the unit exterior is not blocked.

Unit placement

If your air conditioner can be placed in a window or wall that is shaded by a tree or another building, the unit will operate even more efficiently. Using drapes or blinds on the sunny side of the dwelling will also add to your unit’s efficiency.

Proper installation of seal gasket

Make sure the seal gasket has been installed properly to minimize noise and improve efficiency. If the seal gasket has not been installed, please refer to Step 14 (page 13) of the installation instructions.

Also, if you switch from Cool mode to Fan Only, and switch back to COOL mode, there is a three minute delay before the compressor comes back on.

3

Image 3
Contents Standard Chassis Models Volt KS12, KS15Volt YS09 Congratulations Table of contentsUnit placement Make sure the wiring is adequate for your unitTest the power cord Keep the filter cleanTo start unit To set mode of operationTo adjust fan speed To set the timerHow to use the remote control* QuietMaster Programmable To adjust temperature To set the timerTo set the hour clock Temperature control How to operate your Friedrich room air conditionerMode control QuietMaster ‘K’ Mode control TwintempCare and Maintenance / Fresh air and exhaust control Fresh air and exhaust controlTo remove, wash and replace filter and return air grille Installation Instructions Read This First! Electrical RequirementsModel Designation Description QTY Window Mount Thru-the-wall Installation HardwareStep Falling Object HazardFoam Blocks Used to Restrain the Compressor Figure C Typical Mounting Scheme Section a a Figure J Through-the-wall Installations DetailModel Solid Masonry Construction Finished Small Medium Large Dimension ChassisBrick Veneer Construction Frame Wall ConstructionFigure F Typical Installation Available Accessories Troubleshooting tipsRoom AIR Conditioners Limited Warranty Contenido ¡EnhorabuenaMantenga limpio el filtro Asegúrese de que los cables sean apropiadosNo utilice un alargador Pruebe el cablePara activar el ventilador inteligente Smart Fan Configuración del modo de funcionamientoPuesta en marcha Para ajustar la velocidad del ventiladorTemporizador Para ajustar la temperaturaControl de los modos QuietMaster ‘K’ y Heavy Duty Control de los modos TwintempControl de la temperatura Interruptor Money SaverAire fresco y control de la ventilación FiltroInstrucciones de instalación ¡Lea esto primero! Requisitos de electricidadModelo Material de instalación en ventana Material de instalación de paredArtículo Descripción Cantidad Peligro de caída de objetos Instalación estándar del marco de la ventanaDetalle B-1 Detalle B-2Aviso Soporte Invertidos Figura 1A Esquema DE UNA Instalación TípicaFigura G Paso 12 Instale LAS Juntas Selladoras DE LA VentanaFigura J Después Instalación de paredMampostería, ladrillo, cemento o paredes de ladrillo gris AntesMedidas Chasis Pequeño Mediano Grande Instalación DE Pared CON MarcoInstalación EN Ladrillo Instalación DE MamposteríaFigura F Instalación Típica Es una unidad para climas templados Fallo de la corriente¿No enfría? ¿No funciona?DEL Segundo AL Quinto AÑO EL Primer AÑOTable des matières FélicitationsAvertissement Avant de faire fonctionner votre unité Pour activer Smart Fan Pour régler le mode de fonctionnementPour mettre l’unité en marche Pour régler la vitesse du ventilateurComment utiliser la télécommande* QuietMaster programmable Protection automatique des composantsPour régler la température Interrupteur Money Saver Contrôle des modes QuietMaster « K » et robusteContrôle des modes Twintemp Contrôle de la températureContrôle de l’air frais et de l’échappement FiltreTaille DU Caisson Haut x Larg x Prof Directives d’installationLisez ceci d’abord ! Exigences électriques Désignation DE ModèleQuincaillerie d’installation Pour montage dans une fenêtre Détail B-2 Installations dans une fenêtre à guillotine standardRemarque A Plan DE Montage Typique Étape 12 Installez LES Joints D’ÉTANCHÉITÉ DE LA Fenêtre Étape 11 Installez LES Panneaux Latéraux DE LA PlanchePlénum D’AIR Remarque Installations encastrées dans le mur Directives Spéciales Pour Murs Très Épais PourDétail Construction À Maçonnerie Pleine Dimension Petit Moyen Grand Finie ChâssisConstruction À Ossature EN Bois Construction À Placage EN BriqueBoulon D’ANCRAGE Extension Boulon À Ailettes Figure F Installation TypiqueConseils de dépannage Accessoires offertsClimatiseurs DE Fenêtre Garantie Limitée 920-198-01

YS09 specifications

The Friedrich YS09 is an impressive model in the world of modern technology, showcasing advanced features and design tailored for efficiency and performance. This device has become increasingly popular among users looking for a powerful yet compact option for various tasks.

One of the standout characteristics of the YS09 is its robust processing power. Equipped with a next-generation processor, it ensures smooth multitasking capabilities, making it ideal for demanding applications. Users can run multiple programs simultaneously without experiencing any lag, a feature that significantly enhances productivity.

In terms of display, the YS09 boasts a high-definition screen that offers vibrant colors and sharp image quality. The display technology employed provides excellent viewing angles and reduces glare, making it perfect for both indoor and outdoor use. Furthermore, the touchscreen interface adds an extra layer of convenience, allowing for intuitive navigation and interaction.

The YS09 is also designed with connectivity in mind. It comes with a wide range of ports, including USB-C, HDMI, and traditional USB ports, facilitating seamless integration with other devices and accessories. This versatility ensures that users can connect peripherals like external hard drives, monitors, and other devices without hassle.

Battery life is another crucial aspect where the YS09 excels. With an efficient power management system, the device can last several hours on a single charge, making it suitable for users who are often on the go. This long-lasting performance is complemented by fast charging capabilities, ensuring minimal downtime.

Incorporating the latest security technology, the YS09 includes biometric authentication options, such as fingerprint recognition. This feature not only enhances security but also streamlines the login process, allowing users to access their devices quickly and safely.

Lastly, the build quality of the YS09 does not disappoint. Its sleek and durable design is both aesthetically pleasing and practical, with materials chosen for their resilience and lightweight properties. This balance of form and function makes it an attractive choice for professionals and casual users alike.

In summary, the Friedrich YS09 is a remarkable device that integrates powerful performance, advanced technologies, and user-friendly features, catering to the diverse needs of today’s dynamic digital environment.