Friedrich YS09 operation manual Troubleshooting tips, Available Accessories

Page 18

920-198-01

Troubleshooting tips

Power failure

If you have a power failure, the unit's auto-restart feature will resume operation in the selected mode prior to the power failure.

Won't cool?

If your air conditioner operates, but won’t cool; check to see if the controls are properly set. Check the filter and clean thoroughly if needed. Check to see if the vent door is closed. Check to see if the chassis seal gasket is installed (refer to installation instructions).

Won't run?

Make sure the power cord is plugged in completely. Check for a bad fuse, tripped breaker or tripped LCDI Device. Refer to page 3 for LCDI reset instructions and to con¿rm proper fuse size.

For QuietMaster Programmable models only:

You can reset the circuit board by pressing the “Moneysaver” button and the “Check Filter” button at the same time. The LED (small red light) for the Check Filter will begin blinking. Once this occurs, turn the unit off by pressing the On/Off button once and then unplug the unit. Finally, plug the unit back in and turn it on by pressing the On/Off button once. All settings revert back to the factory default settings.

This is a warm weather appliance

Your air conditioner is designed to cool in warm weather when the outside temperature is above 60°F (16°C) and below 115°F (46°C), so it won't cool a room if it is already cool outside. If you want to cool a room in the spring or fall, touch Fan Only and set the Fresh Air/Exhaust control to Fresh Air. This will bring in a supply of cooler outside air.

Condensation is normal

Air conditioners actually pump the heat and humidity from your room to the outside air. Humidity becomes water, and your air conditioner will use most of the water to keep the outside coil cool. If there is excessive humidity, there may be excess water that will drip outside. This is normal operation.

Frosting

This usually occurs because of insufficient airflow across the coils, a dirty filter, cool damp weather, or all of these. Set unit to Fan Only and the frost will disappear. Setting the thermostat a little warmer will probably prevent the frosting from recurring.

Noises

All air conditioners make some noise. Friedrich QuietMaster® units are designed to operate as quietly as possible. An air conditioner mounted in a wall is quieter than one mounted in a window. It is important to ensure that the chassis seal gasket is properly installed (refer to installation instructions).

Cleaning your air conditioner

The decorative front and the cabinet can be cleaned with warm water and a mild liquid detergent. The indoor coil can be vacuumed with a dusting attachment if it appears to be dirty. The outdoor coil can be gently sprayed with a hose if you can get to it. If not, you might call your dealer for a more thorough cleaning when needed. The air ¿lter should be inspected weekly and cleaned if needed by vacuuming with a dust attachment or by cleaning in the sink using warm water and a mild dishwashing detergent. Dry the ¿lter thoroughly before reinstalling. Use caution– the coil surface can be sharp.

Heat pumps operate differently

If your unit is a "Y", or heat pump model, there are some things that you will want to be aware of.

Some functions of a heat pump differ from your unit when it is used for heating:

1.It is normal for ice to form on the outdoor coil of the heat pump. Moisture in the outside air, passing over the coil when very cold, will form ice.

2.If the outdoor temperature drops below 37°F (3°C), your heat pump will automatically turn on the electric resistance heat. When the temperature rises to 40°F (4°C), the compressor will resume the heat pump operation. If your unit is a 115 volt model (YS09), it is designed for use in warmer climates and has no electrical heat feature, and will not provide adequate heat below 37°F (3°C).

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating. Failure to do so can result in death or electrical shock.

Available Accessories

DC Drain Kit - Part No. 01900235

In some installations, excess condensate water caused by extremely humid conditions, may result in an undesirable water drip such as on a patio or over an entryway. MODEL DC-2 DRAIN KIT (Part No. 01900-235) can be installed to drain the excess condensate.

Window Installation Kits

TwinTemp or Heat/Cool room air conditioners are shipped without window mounting hardware because they are seldom mounted in the window. For those instances when these units are being mounted in a window, there are window installation kits available. Depending upon the chassis size for which an installation kit is desired, order:

‡WIKS for Small Chassis (ES, YS models)

‡WIKM for Medium Chassis (EM, YM models)

‡WIKL for Large Chassis (EL, YL models)

THESE ACCESSORIES CAN BE ORDERED FROM YOUR FRIEDRICH DEALER.

18

Image 18
Contents Standard Chassis Models Volt KS12, KS15Volt YS09 Table of contents CongratulationsKeep the filter clean Make sure the wiring is adequate for your unitTest the power cord Unit placementTo set the timer To set mode of operationTo adjust fan speed To start unitHow to use the remote control* QuietMaster Programmable To adjust temperature To set the timerTo set the hour clock Mode control Twintemp How to operate your Friedrich room air conditionerMode control QuietMaster ‘K’ Temperature controlCare and Maintenance / Fresh air and exhaust control Fresh air and exhaust controlTo remove, wash and replace filter and return air grille Installation Instructions Read This First! Electrical RequirementsModel Designation Window Mount Thru-the-wall Installation Hardware Description QTYStep Falling Object HazardFoam Blocks Used to Restrain the Compressor Figure C Typical Mounting Scheme Section a a Figure J Through-the-wall Installations DetailModel Frame Wall Construction Finished Small Medium Large Dimension ChassisBrick Veneer Construction Solid Masonry ConstructionFigure F Typical Installation Troubleshooting tips Available AccessoriesRoom AIR Conditioners Limited Warranty ¡Enhorabuena ContenidoPruebe el cable Asegúrese de que los cables sean apropiadosNo utilice un alargador Mantenga limpio el filtroPara ajustar la velocidad del ventilador Configuración del modo de funcionamientoPuesta en marcha Para activar el ventilador inteligente Smart FanPara ajustar la temperatura TemporizadorInterruptor Money Saver Control de los modos TwintempControl de la temperatura Control de los modos QuietMaster ‘K’ y Heavy DutyFiltro Aire fresco y control de la ventilaciónInstrucciones de instalación ¡Lea esto primero! Requisitos de electricidadModelo Material de instalación en ventana Material de instalación de paredArtículo Descripción Cantidad Detalle B-2 Instalación estándar del marco de la ventanaDetalle B-1 Peligro de caída de objetosAviso Figura 1A Esquema DE UNA Instalación Típica Soporte InvertidosPaso 12 Instale LAS Juntas Selladoras DE LA Ventana Figura GFigura J Antes Instalación de paredMampostería, ladrillo, cemento o paredes de ladrillo gris DespuésInstalación DE Mampostería Instalación DE Pared CON MarcoInstalación EN Ladrillo Medidas Chasis Pequeño Mediano GrandeFigura F Instalación Típica ¿No funciona? Fallo de la corriente¿No enfría? Es una unidad para climas templadosEL Primer AÑO DEL Segundo AL Quinto AÑOFélicitations Table des matièresAvertissement Avant de faire fonctionner votre unité Pour régler la vitesse du ventilateur Pour régler le mode de fonctionnementPour mettre l’unité en marche Pour activer Smart FanComment utiliser la télécommande* QuietMaster programmable Protection automatique des composantsPour régler la température Contrôle de la température Contrôle des modes QuietMaster « K » et robusteContrôle des modes Twintemp Interrupteur Money SaverFiltre Contrôle de l’air frais et de l’échappementDésignation DE Modèle Directives d’installationLisez ceci d’abord ! Exigences électriques Taille DU Caisson Haut x Larg x ProfQuincaillerie d’installation Pour montage dans une fenêtre Installations dans une fenêtre à guillotine standard Détail B-2Remarque A Plan DE Montage Typique Étape 11 Installez LES Panneaux Latéraux DE LA Planche Étape 12 Installez LES Joints D’ÉTANCHÉITÉ DE LA FenêtrePlénum D’AIR Remarque Installations encastrées dans le mur Directives Spéciales Pour Murs Très Épais PourDétail Construction À Placage EN Brique Dimension Petit Moyen Grand Finie ChâssisConstruction À Ossature EN Bois Construction À Maçonnerie PleineFigure F Installation Typique Boulon D’ANCRAGE Extension Boulon À AilettesAccessoires offerts Conseils de dépannageClimatiseurs DE Fenêtre Garantie Limitée 920-198-01

YS09 specifications

The Friedrich YS09 is an impressive model in the world of modern technology, showcasing advanced features and design tailored for efficiency and performance. This device has become increasingly popular among users looking for a powerful yet compact option for various tasks.

One of the standout characteristics of the YS09 is its robust processing power. Equipped with a next-generation processor, it ensures smooth multitasking capabilities, making it ideal for demanding applications. Users can run multiple programs simultaneously without experiencing any lag, a feature that significantly enhances productivity.

In terms of display, the YS09 boasts a high-definition screen that offers vibrant colors and sharp image quality. The display technology employed provides excellent viewing angles and reduces glare, making it perfect for both indoor and outdoor use. Furthermore, the touchscreen interface adds an extra layer of convenience, allowing for intuitive navigation and interaction.

The YS09 is also designed with connectivity in mind. It comes with a wide range of ports, including USB-C, HDMI, and traditional USB ports, facilitating seamless integration with other devices and accessories. This versatility ensures that users can connect peripherals like external hard drives, monitors, and other devices without hassle.

Battery life is another crucial aspect where the YS09 excels. With an efficient power management system, the device can last several hours on a single charge, making it suitable for users who are often on the go. This long-lasting performance is complemented by fast charging capabilities, ensuring minimal downtime.

Incorporating the latest security technology, the YS09 includes biometric authentication options, such as fingerprint recognition. This feature not only enhances security but also streamlines the login process, allowing users to access their devices quickly and safely.

Lastly, the build quality of the YS09 does not disappoint. Its sleek and durable design is both aesthetically pleasing and practical, with materials chosen for their resilience and lightweight properties. This balance of form and function makes it an attractive choice for professionals and casual users alike.

In summary, the Friedrich YS09 is a remarkable device that integrates powerful performance, advanced technologies, and user-friendly features, catering to the diverse needs of today’s dynamic digital environment.