9.ELECTRICAL CONDITION OF BATTERY
9.1The state of charge of
State of Charge of |
| ** Initial Specific Gravity Reading | |||
Battery at 80°F (27°C) | 1.280 |
| 1.265 | 1.225 | Floating Balls |
100% | 1.280 |
| 1.265 | 1.225 | 4 |
75% | 1.240 |
| 1.225 | 1.185 | 3 |
50% | 1.200 |
| 1.190 | 1.150 | 2 |
25% | 1.170 |
| 1.155 | 1.115 | 1 |
Discharged | 1.140 |
| 1.120 | 1.080 | * |
|
|
|
|
|
|
**Initial specific gravity readings vary, depending on battery type and manufacturer. Contact the seller or manufacturer of the battery for this specification.
*No balls float in the barrel of the hydrometer.
9.2The state of charge of
9.3If uncertain about type of battery you will be charging, or the correct procedure for checking the battery’s state of charge, contact the seller or manufacturer of the battery.
9.4The temperature of the battery and the equipment the battery is used with has a dramatic effect on battery efficiency and system power requirements. For example, at 0°F
• •