14.8ENGINE STARTING NOTES:
If the battery is disconnected during the cool down period, the charger will reset.
15.USING BUILT-IN BATTERY TESTER
15.1OVERVIEW
The charger has a
15.2TESTING SEQUENCE
There are four basic steps required to use the charger as a battery tester.
1.Connect the charger battery clamps to the battery.
2.Connect the charger power cord to a 120V AC outlet.
3.If necessary, press the BATTERY TYPE button until the correct type is indicated.
4.Read the voltage on the digital display or press the digital display button to set the tester to Battery % and read the battery percent.
15.3TESTER AND CHARGER
When first turned on, the charger operates only as a tester, not as a charger. To continue to use it as only a tester, avoid pressing the charging/starting button. Selecting a charge rate activates the battery charger and deactivates the tester. Pressing the CHARGING/ startING button when the engine start LED is lit (except during the
180second cool down) will shut off the charger and activate the tester.
15.4POWER-UP IDLE TIME LIMIT
If no button is pressed within 15 minutes after the unit is first powered up, it will automatically switch from tester to charger, if a battery is connected. In that case, the charger will be set for the 2A small battery charge rate and 12V standard battery type.
15.5TESTER WITHOUT TIME LIMIT
If either the DIGITAL Display or Battery Type button is pressed within the first 15 minutes after the unit is powered up, it will remain a tester (not a charger) indefinitely, unless a charge rate is selected.
15.6TESTING AFTER CHARGING
After the unit has been changed from tester to charger (by selecting a charge rate), it remains a charger. To change the unit back to a tester, press the CHARGING/STARTING button until all charge rate LEDs are off.