Hitachi NR83A2(S1), NR83A2(Y) Lubrication, Cold Weather Care, Testing the Nailer, Air consumption

Page 10

English

5. Air consumption

Using the Air consumption table and the Air compressor size formula, find a correct compressor size.

Air consumption table

 

psi

80

90

100

Operating pressure (bar)

(5.5)

(6.2)

(6.9)

 

(kgf/cm2)

(5.6)

(6.3)

(7)

 

 

 

 

 

Air consumption

ft3/cycle

.062

.075

.088

(ltr/cycle)

(1.7)

(2.1)

(2.5)

 

 

 

 

 

 

Air compressor size formula Amount of air required =number of Nailers

average nails driven each minute per Nailer

air consumption at given air pressure

safety factor (always 1.2)

Example: 2 Nailers operating at 100 psi driving 30 nails per minute

Amount of air required =2 30 .088 (2.5) 1.2

=6.3 CFM (ft3/min) (180 ltr/min)

After making the calculations as shown above, you should find a compressor providing 6.3 CFM of air that is required.

LUBRICATION

It is important that the Nailer be properly lubricated. Without proper lubrication, the Nailer will not work properly and parts will wear prematurely.

Use Hitachi pneumatic tool lubricant.

Do not use detergent oil or additives. These lubricants will harm the O-rings and other rubber parts. This will cause the Nailer to malfunction.

Filter-regulator-lubricator units should always be used.

Keep the lubricator filled with Hitachi pneumatic tool lubricant.

If a lubricator is not available, supply 5 – 10 drops of Hitachi pneumatic tool lubricant into the air plug on the Nailer twice a day.

COLD WEATHER CARE

Do not store the Nailer in a cold weather environment. Keep the Nailer in a warm area until beginning the work.

If the Nailer is already cold, bring it in a warm area and allow the Nailer to warm up before use.

1 Reduce the air pressure to 64 psi (4.4 bar

4.5 kgf/cm2).

2Remove all nails from the Nailer.

3Connect the air hose and free-fire (blank-fire) the Nailer.

The lowered air pressure will be enough to free- fire the Nailer.

Slow speed operation tends to warm up the moving part.

CAUTION

Do not free-fire the Nailer at high pressure.

TESTING THE NAILER

DANGER

Operators and others in work area MUST wear safety glasses with side shields which conforms to ANSI Z87.1 specifications.

WARNING

Never use Nailer unless push lever is operating properly.

Before actually beginning the nailing work, test the Nailer by using the checklist below. Conduct the tests in the following order.

If abnormal operation occurs, stop using the Nailer and contact a Hitachi authorized service center immediately.

(1)DISCONNECT AIR HOSE FROM NAILER. REMOVE ALL NAILS FROM NAILER.

ALL SCREWS MUST BE TIGHTENED. If any screws are loose, tighten them.

THE PUSH LEVER AND TRIGGER MUST MOVE SMOOTHLY.

Trigger

Push Lever

Do not connect air hose

(2) Adjust the air pressure to 70 psi (4.9 bar 5 kgf/cm2). Connect the air hose.

— 10 —

Image 10
Contents NR 83A2 Y NR83A2 S1 PeligroContents Single Sequential Actuation Mechanism Important Safety InformationContact Actuation Mechanism Choice of Triggering Method is Important SafetyNever Point Tool AT Yourself or Others in Work Area Always Wear EAR and Head ProtectionStore Nailer Properly Keep Work Area CleanCheck for Live Wires Never USE in Presence of Flammable Liquids or GasesEMPLOYER’S Responsibilities Single Sequential Contact Actuation OperationName of Parts Actuation MechanismStandard Accessories SpecificationsAccessories Nail SelectionBefore Operation Optional AccessoriesApplications Working EnvironmentCold Weather Care Testing the NailerLubrication Air consumptionNailer Must not Operate Adjusting AIR PressureNailer Must not Leak AIR Nailer Must OperateLoading Nails Nailer OperationMethods of Operation MechanismPreviously pull the trigger Trigger Push Lever Disconnect AIR Hose from Nailer Adjusting the Nailing DepthAlways Wear EYE Protection Service and Repairs MaintenanceMaintenance and Inspection Inspecting the magazineAction WHY HOW Problem Check Method CorrectionExplication DE L’ACTION DE Clouage DU Cloueur Hitachi Definition DES Mots DE SignalisationInformation Importante DE Sécurité Mécanisme DE Déclenchement Séquentiel UniqueSecurite AvertissementMaintenir L’AIRE DE Travail Propre Toujours Porter DES Protections ANTI- Bruit ET UN CasqueRanger LE Cloueur Correctement Eloigner LES VisiteursRester SUR SES Gardes Verifier S’IL Y a DES Fils Sous TensionDebrancher LE Tuyau D’AIR DU Cloueur Quand Manipuler LE Cloueur CorrectementResponsabilites DE L’EMPLOYEUR Lunettes DE ProtectionUtilisation NOM DES PiecesAccessoires Standard Accessoires AvertissementSelection DES Clous Avertissement Environnement DE Travail Avertissement Accessoires EN OptionAvant L’UTILISATION Alimentation D’AIREssai DU Cloueur GraissageEntretien PAR Temps Froid Consommation d’airLE Cloueur NE Doit PAS Fonctionner Réglage DE LA Pression D’AIR AvertissementLE Cloueur NE Doit PAS Avoir DE Fuite D’AIR LE Cloueur Doit FonctionnerChargement DES Clous Avertissement Utilisation DU CloueurMéthodes D’UTILISATION Tirer sur la gâchette rapidement et fermementAvertissement Toujours Porter DES Lunettes DE Protection Réglage DE LA Profondeur DE ClouageDebrancher LE Tuyau D’AIR DU Cloueur Entretien ET Reparations Avertissement EntretienEntretien ET Inspection Inspection du magasinProbleme Verification Correction Action Pourquoi CommentExplicación LA Acción DE Clavado DEL Clavador Hitachi Información Importante Sobre SeguridadDefinición DE LAS Palabras Clave Lesiones DE GravedadAdvertencia SeguridadES Importante LA Elección DE Método DE Activación Mantenga EL Área DE Trabajo Limpia Utilice Siempre Protectores Para LOS Oídos Y LA CabezaGuarde Adecuadamente EL Clavador Mantenga a LOS Visitantes AlejadosPermanezca Alerta Compruebe SI HAY Cables ActivosDesconecte LA Manguera DE Aire DEL Clavador Cuando Maneje Correctamente EL ClavadorResponsabilidades DEL Empresario Gafas Protectoras Para LOS OjosNomenclatura OperaciónMecanismo DE Accesorios Advertencia EspecificacionesSelección DE Clavos Advertencia Accesorios EstándarAntes DE LA Operación Accesorios OpcionalesAplicaciones Entorno DE Trabajo AdvertenciaPrecaución LubricaciónCuidados Para Climas Fríos Prueba DEL Clavador PeligroEL Clavador no Deberá Tener Fugas DE Aire LA Palanca DE Empuje Deberá Poder Accionarse SIN DificultadEL Clavador no Deberá Funcionar EL Clavador Deberá FuncionarCarga DE Clavos Advertencia Ajuste DE LA Presión DE Aire Advertencia EL Martillo Automático Deberá Funcionar Adecuadamente Operación DEL Clavador Métodos DE OperaciónAdvertencia Desconecte LA Manguera DE Aire DEL Clavador Ajuste DE LA Profundidad DE ClavadoUtilice Siempre Gafas Protectoras Para LOS Ojos Servicio Y Reparaciones Advertencia MantenimientoMantenimiento E Inspección Inspección del cargadorProblema Método DE Comprobación Solución Acción Para CómoStrip Nailer Parts Name Plate For Model Y, S1 887-903 Standard Accessories Code no Description Steve Reynolds Blvd Norcross, GA Kestrel Road Mississauga on L5T 1Z5