Cisco Systems 2140, 2130 manual Connecting the Appliance DC Power and Ground, Power Connections

Page 63

Chapter 3 Installing the Cisco ADE 2130 and 2140 Series Appliance

Cisco ADE 2130 and 2140 Series Appliance Power

Power Connections

To connect the AC power cord to the Cisco ADE 2130 and 2140 Series appliance:

Caution If only one power supply is installed, it must be in the right-hand slot and a power supply blank filler panel must be installed in the left-hand slot to ensure proper cooling. (See location 5 in Figure 1-5 on page 1-9.)

Step 1 Review the information in the “Safety Warnings” section on page x and the “Safety Guidelines” section on page 2-2.

Warning This equipment must be grounded. Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor. Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available. Statement 1024

Step 2 Plug the AC power cord into the AC power input connector at the rear of the appliance. (See location 5 in Figure 1-5 on page 1-9.)

Step 3 Connect the other end of the power cord to a power source at your site.

Step 4 If you are installing a second redundant AC power supply, repeat Steps 1 and 3 for the second power supply.

Step 5 After confirming that all installation steps are complete, continue with the installation of the network and console cables. (See “Connecting the Network and Console Cables” section on page 3-18.)

Caution Do not power on the unit, yet.

Proceed to the next section,“Grounding the Rack,” to continue the installation.

Grounding the Rack

To avoid the potential for an electrical shock, you must include a third wire safety ground conductor with the rack installation. If the appliance power cord is plugged into an AC outlet that is part of the rack, then you must provide proper grounding for the rack itself. If the appliance power cord is plugged into a wall outlet, the safety ground conductor in the power cord provides proper grounding only for the appliance. You must provide additional, proper grounding for the rack.

Connecting the Appliance DC Power and Ground

Before you can connect DC power to the Cisco ADE 2130 and 2140 Series appliance, you must provide an adequate chassis ground (earth) to your appliance.

To avoid the potential for an electrical shock, you must connect an earth ground conductor to the appliance. The earth ground conductor must be connected to a 10-to-14 AWG copper wire to the earth ground studs on the rear of the appliance (see location 3 in Figure 1-5 on page 1-9). The ground

Cisco Application Deployment Engine (ADE) 2130 and 2140 Series Appliance Hardware Installation Guide

 

78-18579-02

3-13

 

 

 

Image 63
Contents Text Part Number Americas HeadquartersCopyright 2008 Cisco Systems, Inc. All rights reserved N T E N T S Lifting Guidelines Preparing Your Site for Installation Powering Up the Cisco ADE 2130 and 2140 Series Appliance Appliance C-2 About This Guide Organization Document Revision HistoryObjectives AudienceChapter Title Description ConventionsBewaar Deze Instructies Safety WarningsWarnung Wichtige Sicherheitshinweise Avvertenza Importanti Istruzioni Sulla SicurezzaAviso Instruções Importantes DE Segurança Spara Dessa Anvisningar GEM Disse Anvisninger Xiv Related Documentation Obtaining Documentation and Submitting a Service RequestXvi A P T E R Model Product OverviewProduct Serial Number Location Cisco ADE 2130 and 2140 Series Appliance Configurations Cisco Product Identification ToolCisco ADE 2130 Series Appliance CADE-2U-AC-PSU= Specification Description Cisco Spare Part NumberCisco ADE 2140 Series Appliance GB Sdram CADE-RAM-25EF=Cisco ADE 2130 and 2140 Series Appliance Front View Hardware FeaturesColor State Description Front Control Panel LEDs and SwitchesCisco ADE 2130 and 2140 Series Appliance Rear View SwitchUsed used NIC LEDsAC and DC Power Supply LEDs Ethernet Port NIC 1 and NIC Input/Output Ports and ConnectorsEthernet Port Pin Signal Description Serial Console PortType Description Signal Description RTS CTS DTR DSR TXD RXD GND RJ-45-to-DB-9 Terminal Adapter ConsoleDC Power Supply Input AC and DC Power SuppliesOvercurrent Protection OCP Overtemperature Protection OTPEnvironmental Monitoring Regulatory ComplianceA P T E R General Precautions Safety GuidelinesSafety with Electricity Safety with EquipmentPage Preventing Electrostatic Discharge Damage Preparing Your Site for Installation Lifting GuidelinesSite Planning Post Open Rack Rack Installation Safety GuidelinesSite Environment Airflow Guidelines Temperature and Humidity GuidelinesSpecification Minimum Maximum Power ConsiderationsDC Power Supply Safety Considerations Method of ProcedureUnpacking and Checking the Contents of Your Shipment Cisco Part Number Cisco Information Packet and WarrantyRequired Tools and Equipment Duration of Hardware WarrantyReplacement, Repair, or Refund Policy for Hardware To Receive a Return Materials Authorization RMA NumberInstallation Checklist Creating a Site LogTask Verified by Date Ethernet and Console Port Considerations NIC 1 and NIC 2 RJ-45 Ethernet ConnectionsSerial Console Port Connections 78-18579-02 Page Installing the Cisco ADE 2130 and 2140 Series Appliance Rack-Mounting Configuration Guidelines Installing the Cisco ADE 2130 and 2140 Series Appliance 2-Post Rack-Mount Kit Post Rack-Mount Hardware KitAttaching the L Brackets to the Appliance Mid-Mounting in a 2-Post RackAttaching an L Bracket to a Center Post Installing the Appliance in the Rack4-post Rails and Brackets Item No Description Quantity Attaching the Inner Slide Rails to the ApplianceAttaching the Outer Slide Rails to the Rack Installing the Appliance into the RackInstalling Appliance into Rack Cisco ADE 2130 and 2140 Series Appliance Power Connecting the Appliance AC Power Connecting the Appliance DC Power and Ground Power ConnectionsGrounding the Rack Grounding Connections 10 Stripping the Ground Wire Wiring the DC-Input Power Source 12 Stripping the Power Wire Connecting the Network Interface Connecting the Network and Console CablesCable Management Connecting the ConsolePower-Up Procedure AC Power Supply Powering Up the Cisco ADE 2130 and 2140 Series ApplianceChecking the LEDs Power-Up Procedure DC Power SupplyADE 2130 and 2140 Appliance Front-Panel LEDs A P T E R Description Cisco Spare Part Number Preparing for a Successful InstallationBefore You Begin Hardware OptionsBeginning the Installation Tools and Supplies NeededRemoving the Cover Removing the Cisco ADE 2130 and 2140 Series Appliance Cover Removing the Front Bezel Installing a Hard Drive Tray into the ApplianceRemoving the Hard Drive Tray Removing the Processor Air Duct Removing and Installing the Processor Air DuctTo remove the processor air duct Installing the Processor Air Duct Installing and Removing MemoryBranch Channel B Channel a Installing DIMMs Installing DIMMsRemoving DIMMs Removing and Installing the PCI Adapter CardConfiguration Lower Slot Upper Slot Configuration Bottom Slot Middle Slot Top SlotPCI riser assembly Pins Removing the PCI Riser AssemblyRemoving a Full-Height Adapter Card Removing a PCI Adapter CardInstalling a PCI Adapter Card Installing the PCI Riser Assembly Installing or Replacing a Power SupplyAC and DC Power Supply Modules Replacing a Redundant Power SupplyAdding a New Redundant Power Supply Replacing a Nonredundant Power SupplyInstalling the Cover Completing the Installation231198 Page Troubleshooting Overview TroubleshootingProblem Solving Environmental Reporting Features Troubleshooting the Power and Cooling SystemsTroubleshooting Adapter Cards, Cables, and Connections Front-Panel LEDs Reading the LEDsFigure A-2 NIC 1 and NIC 2 LEDs NIC LEDsCisco Product Identification Tool Product Serial Number LocationPage Site Log Initials DateMaintaining Your Site Environment Maintaining the Cisco ADE 2130 ApplianceAdapter Cards General Exterior Cleaning and InspectionCables and Connectors ApplianceCooling TemperatureElectromagnetic and Radio Frequency Interference HumidityAltitude Electrostatic DischargeMagnetism Power Source InterruptionsPage Numerics EMI See ESDNIC See MOPRFI Preventing effects RJ-45 pinout NIC Safety guidelinesIN-5 IN-6