Cisco Systems 2130, 2140 manual Site Environment

Page 40

Chapter 2 Preparing to Install the Cisco ADE 2130 and 2140 Series Appliance

Preparing Your Site for Installation

2-Post (Telco) Rack

Figure 2-1c shows a 2-post (telco-type) rack. This rack is an open frame consisting of two posts tied together by a crossbar at the top and a floor stand at the bottom.

This type of rack is usually secured to the floor and sometimes to an overhead structure or wall for additional stability. The Cisco ADE 2130 or 2140 Series appliance can be installed in this rack either in

afront-mounted position or a mid-mounted position.

In the front-mounted position, you secure the appliance rack-mounting brackets directly to the rack posts.

In the mid-mounted position, you secure a set of optional mid-mount brackets to the rack posts. The appliance rack-mounting flanges are then secured to the mid-mount brackets. The mid-mounted position moves the center of gravity closer to the appliance and closer to the vertical axis of the rack posts, which adds to the stability of the rack installation.

Before installing your Cisco ADE 2130 and 2140 Series appliance in a rack, review the following guidelines:

Two or more people are required to install the appliance in a rack.

Ensure that the room air temperature is below 95°F (35°C).

Do not block any air vents; usually 6 inches (15 cm) of space provides proper airflow.

Plan the appliance installation starting from the bottom of the rack.

Do not extend more than one appliance out of the rack at the same time.

Connect the appliance to a properly grounded outlet.

Do not overload the power outlet when installing multiple devices in the rack.

Do not place any object weighing more than 110 lb (50 kg) on top of rack-mounted devices.

Site Environment

The location of your appliance and the layout of your equipment rack or wiring room are important considerations for proper operation. Equipment placed too close together, inadequate ventilation, and inaccessible panels can cause malfunctions and shutdowns, and can make maintenance difficult. Plan for access to front and rear panels of the appliance.

The following precautions will help you plan an acceptable operating environment for your appliance and will help you avoid environmentally caused equipment failures:

Ensure that the room where your appliance operates has adequate circulation. Electrical equipment generates heat. Without adequate circulation, ambient air temperature may not cool equipment to acceptable operating temperatures (see the “Airflow Guidelines” section on page 2-9).

Ensure the site of the rack includes provisions for source AC power, grounding, and network cables.

Allow sufficient space to work around the rack during the installation. You need:

At least 3 feet (9.14 m) adjacent to the rack to move, align, and insert the appliance.

At least 24 inches (61 cm) of clearance in front of and behind the appliance for maintenance after installation.

To mount the appliance between two posts or rails, the usable aperture (the width between the inner edges of the two mounting flanges) must be at least 17.7 inches (45.0 cm).

If you use a 2-post (telco-type) rack, the weight of several appliances is cantilevered off of the two rack posts. Make sure that:

Cisco Application Deployment Engine (ADE) 2130 and 2140 Series Appliance Hardware Installation Guide

2-8

78-18579-02

 

 

Image 40
Contents Americas Headquarters Text Part NumberCopyright 2008 Cisco Systems, Inc. All rights reserved N T E N T S Lifting Guidelines Preparing Your Site for Installation Powering Up the Cisco ADE 2130 and 2140 Series Appliance Appliance C-2 About This Guide Document Revision History ObjectivesAudience OrganizationConventions Chapter Title DescriptionSafety Warnings Bewaar Deze InstructiesAvvertenza Importanti Istruzioni Sulla Sicurezza Warnung Wichtige SicherheitshinweiseAviso Instruções Importantes DE Segurança Spara Dessa Anvisningar GEM Disse Anvisninger Xiv Obtaining Documentation and Submitting a Service Request Related DocumentationXvi A P T E R Product Overview ModelProduct Serial Number Location Cisco Product Identification Tool Cisco ADE 2130 and 2140 Series Appliance ConfigurationsCisco ADE 2130 Series Appliance Specification Description Cisco Spare Part Number Cisco ADE 2140 Series ApplianceGB Sdram CADE-RAM-25EF= CADE-2U-AC-PSU=Hardware Features Cisco ADE 2130 and 2140 Series Appliance Front ViewFront Control Panel LEDs and Switches Color State DescriptionSwitch Cisco ADE 2130 and 2140 Series Appliance Rear ViewNIC LEDs Used usedAC and DC Power Supply LEDs Input/Output Ports and Connectors Ethernet Port NIC 1 and NICSerial Console Port Ethernet Port Pin Signal DescriptionType Description Signal Description RJ-45-to-DB-9 Terminal Adapter Console RTS CTS DTR DSR TXD RXD GNDAC and DC Power Supplies DC Power Supply InputOvertemperature Protection OTP Environmental MonitoringRegulatory Compliance Overcurrent Protection OCPA P T E R Safety Guidelines General PrecautionsSafety with Equipment Safety with ElectricityPage Preventing Electrostatic Discharge Damage Lifting Guidelines Preparing Your Site for InstallationSite Planning Rack Installation Safety Guidelines Post Open RackSite Environment Temperature and Humidity Guidelines Airflow GuidelinesPower Considerations Specification Minimum MaximumMethod of Procedure DC Power Supply Safety ConsiderationsUnpacking and Checking the Contents of Your Shipment Cisco Information Packet and Warranty Cisco Part NumberDuration of Hardware Warranty Replacement, Repair, or Refund Policy for HardwareTo Receive a Return Materials Authorization RMA Number Required Tools and EquipmentCreating a Site Log Installation ChecklistTask Verified by Date NIC 1 and NIC 2 RJ-45 Ethernet Connections Ethernet and Console Port ConsiderationsSerial Console Port Connections 78-18579-02 Page Installing the Cisco ADE 2130 and 2140 Series Appliance Rack-Mounting Configuration Guidelines Installing the Cisco ADE 2130 and 2140 Series Appliance Post Rack-Mount Hardware Kit 2-Post Rack-Mount KitMid-Mounting in a 2-Post Rack Attaching the L Brackets to the ApplianceInstalling the Appliance in the Rack Attaching an L Bracket to a Center Post4-post Rails and Brackets Attaching the Inner Slide Rails to the Appliance Item No Description QuantityInstalling the Appliance into the Rack Attaching the Outer Slide Rails to the RackInstalling Appliance into Rack Cisco ADE 2130 and 2140 Series Appliance Power Connecting the Appliance AC Power Power Connections Connecting the Appliance DC Power and GroundGrounding the Rack Grounding Connections 10 Stripping the Ground Wire Wiring the DC-Input Power Source 12 Stripping the Power Wire Connecting the Network and Console Cables Connecting the Network InterfaceConnecting the Console Cable ManagementPowering Up the Cisco ADE 2130 and 2140 Series Appliance Power-Up Procedure AC Power SupplyPower-Up Procedure DC Power Supply Checking the LEDsADE 2130 and 2140 Appliance Front-Panel LEDs A P T E R Preparing for a Successful Installation Before You BeginHardware Options Description Cisco Spare Part NumberTools and Supplies Needed Beginning the InstallationRemoving the Cover Removing the Cisco ADE 2130 and 2140 Series Appliance Cover Installing a Hard Drive Tray into the Appliance Removing the Front BezelRemoving the Hard Drive Tray Removing and Installing the Processor Air Duct Removing the Processor Air DuctTo remove the processor air duct Installing and Removing Memory Installing the Processor Air DuctBranch Channel B Channel a Installing DIMMs Installing DIMMsRemoving and Installing the PCI Adapter Card Removing DIMMsConfiguration Bottom Slot Middle Slot Top Slot Configuration Lower Slot Upper SlotRemoving the PCI Riser Assembly PCI riser assembly PinsRemoving a PCI Adapter Card Removing a Full-Height Adapter CardInstalling a PCI Adapter Card Installing or Replacing a Power Supply Installing the PCI Riser AssemblyReplacing a Redundant Power Supply AC and DC Power Supply ModulesReplacing a Nonredundant Power Supply Adding a New Redundant Power SupplyCompleting the Installation Installing the Cover231198 Page Troubleshooting Troubleshooting OverviewProblem Solving Troubleshooting the Power and Cooling Systems Environmental Reporting FeaturesTroubleshooting Adapter Cards, Cables, and Connections Reading the LEDs Front-Panel LEDsNIC LEDs Figure A-2 NIC 1 and NIC 2 LEDsProduct Serial Number Location Cisco Product Identification ToolPage Site Log Date InitialsMaintaining the Cisco ADE 2130 Appliance Maintaining Your Site EnvironmentGeneral Exterior Cleaning and Inspection Cables and ConnectorsAppliance Adapter CardsTemperature CoolingHumidity AltitudeElectrostatic Discharge Electromagnetic and Radio Frequency InterferencePower Source Interruptions MagnetismPage Numerics See ESD EMISee MOP NICPreventing effects RJ-45 pinout NIC Safety guidelines RFIIN-5 IN-6