WARNING

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Do not spray flammable or combustible materials near an open flame or sources of ignition such as cigarettes, motors, and electrical equipment.

Paint or solvent flowing through the equipment is able to result in static electricity. Static electricity creates a risk of fire or explosion in the presence of paint or solvent fumes. All parts of the spray system, including the pump, hose assembly, spray gun, and objects in and around the spray area shall be properly grounded to protect against static discharge and sparks. Use Graco conductive or grounded high-pressure airless paint sprayer hoses.

Verify that all containers and collection systems are grounded to prevent static discharge.

Connect to a grounded outlet and use grounded extensions cords. Do not use a 3-to-2 adapter.

Do not use a paint or a solvent containing halogenated hydrocarbons.

Keep spray area well-ventilated. Keep a good supply of fresh air moving through the area. Keep pump assembly in a well ventilated area. Do not spray pump assembly.

Do not smoke in the spray area.

Do not operate light switches, engines, or similar spark producing products in the spray area.

Keep area clean and free of paint or solvent containers, rags, and other flammable materials.

Know the contents of the paints and solvents being sprayed. Read all Material Safety Data Sheets (MSDS) and container labels provided with the paints and solvents. Follow the paint and solvents manufacturer’s safety instructions.

Fire extinguisher equipment shall be present and working.

Sprayer generates sparks. When flammable liquid is used in or near the sprayer or for flushing or cleaning, keep sprayer at least 20 feet (6 m) away from explosive vapors.

SKIN INJECTION HAZARD

Do not aim the gun at, or spray any person or animal.

Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the body.

Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.

Use Graco nozzle tips.

Use caution when cleaning and changing nozzle tips. in the case where the nozzle tip clogs while spraying, fol- low the Pressure Relief Procedure for turning off the unit and relieving the pressure before removing the noz- zle tip to clean.

Do not leave the unit energized or under pressure while unattended. When the unit is not in use, turn off the unit and follow the Pressure Relief Procedure for turning off the unit.

High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injec- tion occurs, get immediate surgical treatment.

Check hoses and parts for signs of damage. Replace any damaged hoses or parts.

This system is capable of producing 3300 psi. Use Graco replacement parts or accessories that are rated a minimum of 3300 psi.

Always engage the trigger lock when not spraying. Verify the trigger lock is functioning properly.

Verify that all connections are secure before operating the unit.

Know how to stop the unit and bleed pressure quickly. Be thoroughly familiar with the controls.

4

310820E

Image 4
Contents Hi-Boy ProStep 310820E Grounding Instructions GroundingFire and Explosion Hazard Skin Injection HazardEquipment Misuse Hazard Electric Shock HazardPressurized Aluminum Parts Hazard Burn HazardAvertissement Instructions de mise à la terreMise EN Garde Risques DE Brûlure Risques DUS AUX Pièces EN Aluminium Sous PressionÉquipement DE Protection Personnelle Instrucciones de conexión a tierra AdvertenciaConexión a Tierra Peligro DE Incendios Y Explosiones Peligro DE Inyección a Través DE LA PielPeligros Debidos a LA Utilización Incorrecta DEL Equipo Peligro DE Descarga EléctricaPeligro DE Piezas DE Aluminio a Presión Peligro DE QuemadurasIstruzioni di messa a terra AvvertenzaMessa a Terra Pericolo DI Incendi ED Esplosioni Pericolo DI Iniezione Nella PellePericolo DA Utilizzo Errato DELL’ATTREZZATURA Pericolo DI Scosse ElettrichePericolo DA Parti in Alluminio Pressurizzate Pericolo DI UstioniInstruções de ligação à terra AdvertênciaLigação À Terra Perigo DE Incêndio E Explosão Perigo DE Injecção Através DA PelePerigo DE MÁ Utilização do Equipamento Perigo DE Choque EléctricoPerigo DE Peças DE Alumínio Pressurizado Perigo DE QueimadurasAardingsinstructies WaarschuwingAarding BRAND- EN Explosiegevaar Gevaar Voor Injectie Door DE HuidGevaren BIJ Verkeerd Gebruik VAN DE Apparatuur Gevaar Voor Elektrische SchokkenGevaren VAN Aluminium Onderdelen Onder Druk Gevaar VAN BrandwondenMARCHE/ARRÊT Pressure Metal flushing pail. Trigger gun to Aarding verlaagt de Power Requirements Extension Cords Pails Ti2702b Ti5301a Flush Turn Pressure Relief, Seconds Heavy edges Om de verstopping eruit te spuiten Met spuiten Waste Turn Flush Pump Armor 310820E Ti11587a Ti11586a Ti11612a Ti11585a 310820E Ti11584a Ti11605a Ti11607a Ti11603a Ti11604a Ti11584a Ti11606a Technical Data Caractéristiques techniquesCaracterísticas técnicas Dati tecniciFicha Técnica Technische gegevensTechnische gegevens Additional Warranty Coverage For Graco Canada CustomersPour LES Clients DE Graco Parlant Francais Para LOS Clientes DE Graco QUE Hablan EspañolGraco INC. P.O. BOX 1441 MINNEAPOLIS, MN