TABLE ADJUSTMENTS
1.Raise or lower the table on the column by loosening the table clamp (A) Fig. 23, and turning the table raising and lowering handle (B) Fig. 24. After the table is at the desired height, tighten the clamp (A) Fig. 23.
NOTE: Always raise (rather than lower) the table to the final position to allow the gears to mesh and prevent slippage.
2.The table can be rotated 360 degrees on the column by loosening the clamp (A) Fig. 23, rotating the table to the desired position, and tightening the clamp (A).
D
C E
Fig. 25
3.The table can be tilted right or left by removing the table alignment pin (C) Fig. 25.
NOTE: If the pin (C) is difficult to remove, turn the nut (E) clockwise to pull the pin out of the casting.
4.Loosen the table locking bolt (D) Fig. 26, tilt the table to the desired angle, and tighten the bolt (D). When you return the table to the level position, replace the table alignment pin (C) Fig. 25 to position the table surface 90 degrees to the spindle.
5.A tilt scale (E) Fig. 27 is provided on the table bracket casting to indicate the degree of tilt. A witness line and zero mark (F) are also provided on the table to align with the scale (E).
A
Fig. 23
B
Fig. 24
C
D
Fig. 26
F | E |
| |
| Fig. 27 |
15