Table 10 Fault Symptom Codes (continued) |
|
| |
|
|
| |
FSC | Message | ERP | |
20c0 | Drive In Error | • | Press the Enter button to clear the |
| (Control failed to set SCSI ID.) |
| message. |
| • | Ensure the drive shows good status | |
|
| ||
|
|
| through the drive status window. |
|
| • Check SCSI ID settings. | |
|
| • Cycle power to the library or reboot | |
|
|
| using the GUI touch screen. |
|
|
|
|
20c1 | Drive In Error | • | Press the Enter button to clear the |
| (Control failed on installed drive.) |
| message. |
| • | Ensure the drive shows good status | |
|
| ||
|
|
| through the drive status window. |
|
| • Check SCSI ID settings. | |
|
| • | Check cabling. |
|
| • Cycle power to the library or reboot | |
|
|
| using the GUI touch screen. |
|
|
|
|
3000 | Motor Fault Condition | • | Press the Enter button to reboot. |
| (One of the robot motors has been | • | Cycle power to the library or reboot |
| disabled and could not be |
| using the GUI touch screen. |
|
|
|
|
3002 | Picker Tach Errors | • | Press the Enter button to reboot. |
| (Picker tachometer errors were detected | • | Cycle power to the library or reboot |
| when checking slots.) |
| using the GUI touch screen. |
|
|
|
|
3005 | • | Power down the library using the LCD | |
| (Excessive Pass through elevator tach |
| touch display. |
| • | Remove | |
| errors.) | ||
|
|
| connections. |
|
|
|
|
3011 | Bin Fetch Failure | • | Press the Enter button to reboot. |
| (Loader failed to fetch a cartridge from a | • | Ensure cartridges are fully inserted in the |
| bin.) |
| magazine(s). |
|
| • Ensure that there are no obstructions | |
|
|
| inside the library (all cartridges are in |
|
|
| magazines). |
|
| • Run the cartridge cycle diagnostic to | |
|
|
| verify. |
|
| • Check the tape cartridge used in the last | |
|
|
| operation for damage. |
|
|
|
|