HP MSL6000 manual Drive and Slot Numbering

Page 62

Table 5 View Library Options (continued)

Option

Description

Drive and Slot Numbering

Lets you specify whether SCSI elements in the library displays

 

with either zero based or one based. Note that this only affects

 

the GUI touch screen, not the actual SCSI element addresses. The

 

default is Zero Based.

 

 

Library Mode

Lets you set the robotics operating mode to Random, Sequential

 

Drv0, Sequential Drv n (two or more drives), or Sequential Split.

 

Sequential Drive n and Sequential Split require two or more

 

drives in the library. Sequential mode is not available with

 

multi-module configurations. The default is Random.

 

 

Sequential Mode

Sequential Mode is locally controlled. Sequential operations

 

begin with any cartridge loaded into Drive 0. The library

 

monitors the drive status, and when the host unloads a cartridge

 

from the drive, it returns the cartridge to the magazine, and then

 

loads the next cartridge in magazine numerical order. This

 

operation continues until all cartridges have been loaded, or

 

until an empty slot is encountered. Two options are available:

 

Normal (same as Library Mode above) and Recirculate. Instead

 

of stopping after the cartridge in the last slot for the drive has

 

been unloaded by the host, Recirculate mode continues the

 

operation by loading the first cartridge for the drive.

 

Recirculation will continue until an empty slot is encountered, or

 

the operator unloads the tape using the GUI touch screen.

 

 

LCD Contrast Adjust

The LCD contrast controls let you increase or decrease the

 

contrast of the LCD display. The incremental steps are set by

 

adjusting the LCD Contrast Adjust option from the Library option.

 

Incremental steps can range from 0 to 31 depending on your

 

preference. The default is 16.

 

 

Mail-Slot Mode

Lets you enable or disable the mail slot(s) in a library. For the

 

two-drive models, the default is Mail Slot Enabled. For the

 

four-drive models, the default is Both Mail Slots Enabled.

 

 

Barcode Label Size

Lets you limit the length of the bar code label. Possible settings

 

are 1 through 8. The default is 8.

 

 

Barcode Label Assignment

Lets you specify the alignment of a bar code label. The options

 

are Left or Right. When used in conjunction with the Barcode

 

Label Size option, this option strips unwanted trailing characters

 

(left alignment) or leading characters (right alignment). The

 

default is Left Align.

 

 

Barcode Label Check Digit

Lets you specify whether to enable or disable the verification of a

 

check digit character in the bar code label. The default is

 

Disabled.

 

 

62 Operation

Image 62
Contents HP StorageWorks MSL6000 series tape library user guide Page Contents Operation Remote Management InterfaceRegulatory compliance notices MaintenanceTroubleshooting Specifications Optional Fibre Channel Card Configuration ExamplesElectrostatic Discharge Index FiguresPage Tables Page About this guide Related documentationDocument conventions and symbols Document conventions Convention ElementHelpful web sites HP technical supportHP-authorized reseller Page Introduction ModelsAccessories Tape Drives Ultrium Tape Drives Library tape drive locationsUltrium Tape Cartridges HP Ultrium 960 format trademarkSdlt Tape Drives Sdlt Tape Cartridges Magazines Power Supplies Library power suppliesRobotics Library Controller BoardLibrary controller board Factory-Defined Accessory PCI Slots Library controller board connectionsFront Panel Indicators Embedded Network Storage Router OptionalMulti Unit Library Systems Library front panelLibrary PTM mounting location Installation Converting a Tabletop Model to a Rackmount ModelSetting Up the Rackmount Model Converting a tabletop model four-drive model shownMSL6000 series tape library user guide Installation MSL6000 series tape library user guide Converting a Rackmount Model to a Tabletop Model Securing the libraryApplying Power to the Library Converting a rackmount model two-drive model shownCabling for Scsi Configurations Supported Scsi Cables Two Tape Drives, Dual Host SystemFour Tape Drives, Dual Host System Setting a Scsi ID Library ConfigurationChanging Default Configuration Settings Library Configuration Setting Up a Reserved Slot Reserved Slot Numbering #24 #23 #22 #21 #20 #19 #18 #17 #16 #15 #14 #13 #12Reserved slot locations, Ultrium MSL6030 Reserved slot locations, lower module, Sdlt Cleaning Slot #2 Cleaning Slot #0 Cleaning Slot #1 Library Configuration Configuring the Network Settings IP address determination screenLibrary Configuration Magazine Doors OperationFront Panel Magazine door mechanical releases emergency access GUI Touch Screen IndicatorsFront Panel and Media Security Locks Operation Library Status Screen Library Display Screens and OptionsInitialization Screen Host SystemOperation Technical Support Information Mail Slot Access Left-hand Magazines OnlyMagazine Access Magazine access screen two-drive model shown Move MediaPower GUI Contrast ControlsPower-down confirmation message screen Status Menu Cartridge Map Online Library Options Menu SelectionsView System Data Area Enabled Drive and Slot Numbering Module Configuration Scsi OptionsSCSI-3 PID Generate Unit Attention Reports Default view network options screen Network OptionsLibrary Edit Options AreaLibrary Info Scsi Network PasswordsUtilities Area Diagnostics Diagnostics screen four-drive model shownSecurity Level Inserting and Removing Tape CartridgesFactory Removing Magazines Removing tape cartridge magazinesUsing Mail Slots Left-hand Magazines Only Inserting Cartridges into a MagazineLabeling Tape Cartridges Left-hand magazine mail slot two-drive model shownUltrium Labels Attaching a bar code label to an Ultrium tape cartridgeProper Ultrium bar code label placement Sdlt LabelsMedia Label Identifiers Attaching a bar code label to an Sdlt tape cartridgeRemote Management Interface OverviewAccessing the Remote Management Interface MSL6000 series tape library user guide Using Menu Buttons StatusMove Media Click Execute the MoveSetup Setup screenLibrary configuration screen Scsi Configuration Drive ConfigurationFunctions Changing the Remote Management Interface Passwords HistoryMSL6000 series tape library user guide Remote Management Interface Maintenance Using the Library Maintenance MenuMaintaining Tape Cartridges Running a Cleaning Cartridge Ultrium Cartridges Sdlt CartridgesAutomatically Running a Cleaning Cartridge Manually Running a Cleaning CartridgeRunning a Cleaning Cartridge from a Cleaning Slot Running a Cleaning Cartridge from a Mail SlotRunning a Cleaning Cartridge from a Tape Cartridge Slot Replacing a Cleaning Cartridge in a Mail Slot Replacing a Cleaning Cartridge in a Reserved SlotReplacing a Cleaning Cartridge in a Right Magazine Updating firmware using the Remote Management Interface Updating FirmwareUsing HP StorageWorks Library & Tape Tools Using a Serial ConnectionFirmware Flashing Procedure Maintenance Troubleshooting Identifying Platform ProblemsPerforming Error Recovery Troubleshooting flow chartFault Symptom Codes FSCs ERPEnsure Scsi options are set correctly FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC Null FSC FSC Magazine in the master module FSC FSC Troubleshooting General Problems Troubleshooting Run a Vertical Calibration test from Check the host device file system access permissions Lvds or single-ended Scsi and is properly installed Using Diagnostic Support Tools RAIDMSLUtil Running Library Diagnostic TestsHP StorageWorks Library and Tape Tools Their status Federal Communications Commission notice Regulatory compliance noticesRegulatory compliance identification numbers FCC rating labelCables Canadian notice Avis CanadienModification Class a equipmentClass B equipment European Union noticeJapanese notices Taiwanese notices Japanese power cord statementKorean notices Class a equipment Class B equipmentTaiwan battery recycle statement Laser compliance noticesDutch laser notice French laser notice German laser notice Italian laser noticeRecycling notices Japanese laser notice Spanish laser noticeCzecholslovakian notice Danish noticeDutch notice Estonian notice Finnish notice French noticeGerman notice Greek noticeHungarian notice Italian notice Latvian notice Lithuanian notice Polish notice Portuguese notice Descarte de Lixo Elétrico na Comunidade EuropéiaSlovakian notice Slovenian notice Spanish notice Swedish notice Mechanical SpecificationsPower Environmental All Models Safety and Regulatory AcousticsSpecifications Electrostatic Discharge Grounding MethodsElectrostatic Discharge Configuration Examples Scsi Cable ConfigurationsConfiguration Examples MSL6030/MSL6026, 2 hosts/2 drivesOptional Fibre Channel Card Host PrerequisitesSerial Port Connectors and IndicatorsPower Indicator Default Ethernet Settings ConfigurationScsi Vhdci Connectors Ethernet PortMSL6030/MSL6026 standalone MSL6060/MSL6052 standalone Optional Fibre Channel Card Index FCC170 PTM 176 Figures Page Page Page Tables