Environmental (All Models)
Table 15 Operating Environmental Specifications
Description | Specification |
Dry bulb temperature | 50°F to 95°F (10°C to 35°C) |
|
|
Temperature gradient | 1.8°F/min (1°C/min) |
|
|
Temperature shock | 27°F (15°C) over 2 minutes |
|
|
Wet bulb temperature | 78.8°F (26°C) |
|
|
Relative humidity (noncondensing) | 20% to 80% |
|
|
Humidity gradient | 10%/hr |
|
|
Altitude | |
| 3050 m) |
|
|
Table 16 Packed or Unpacked Environmental Specifications | |
|
|
Description | Specification |
Dry bulb temperature | |
|
|
Temperature gradient | 36°F (20°C)/hr (across the range) |
|
|
Temperature shock | 27°F (15°C) (over 2 minutes) |
|
|
Wet bulb temperature | 86°F (30°C) |
|
|
Relative humidity (noncondensing) | 10% to 95% |
|
|
Humidity gradient | 10%/hr |
|
|
Altitude | |
| 4600 m) |
|
|
Table 17 Transit | |
|
|
Description | Specification |
Dry bulb temperature | |
|
|
Temperature gradient | 36°F (20°C)/hr (across the range) |
|
|
Temperature shock | 27°F (15°C) (over 2 minutes) |
|
|
Wet bulb temperature | 86°F (30°C) |
|
|
Relative humidity (noncondensing) | 5% to 95% |
|
|
Humidity gradient | 10%/hr |
|
|
Altitude | |
| 12,200 m) |
|
|
160 Specifications