HP MSL6000 manual Enabled

Page 61

Figure 48 View library options screen

Table 5 lists and describes the available Library options.

Table 5 View Library Options

 

 

 

Option

Description

Library Remains Offline After

Library does not go online after power-up initialization. You

Power-up Initialization

must select the Online option from the Menu screen on the GUI

 

touch screen. The default is Disabled.

 

 

Auto Power-Up An Installed

Enables a tape drive to be automatically powered up (after a

Drive After Timeout

delay), after replacing a tape drive if you do not explicitly power

 

up the tape drive from the GUI touch screen. The default is

 

Enabled.

 

 

Unload Mode

Lets you determine whether a SCSI MOVE MEDIUM command

 

is interpreted as Implicit or Explicit. If Implicit, the library unloads

 

a tape drive before attempting to move a cartridge from that

 

tape drive. If Explicit, the host must issue a SCSI UNLOAD

 

command to a tape drive before each MOVE MEDIUM

 

command that removes a cartridge from that tape drive. The

 

default is Implicit.

 

 

Total Reserved Slots

Lets you reduce a specified number of slots at the rear of a

 

magazine. Some host software imposes size limits on library

 

magazines for licensing purposes, and does not operate with a

 

library that exceeds the licensed size. The default is 0.

 

 

Auto Clean Mode

Lets you enable an automatic tape drive cleaning cycle. To use

 

this option, you must have reserved a slot for a cleaning

 

cartridge using the Total Reserved Slots option. The default is

 

Disabled.

 

 

MSL6000 series tape library user guide 61

Image 61
Contents HP StorageWorks MSL6000 series tape library user guide Page Contents Remote Management Interface OperationTroubleshooting MaintenanceRegulatory compliance notices Specifications Electrostatic Discharge Configuration ExamplesOptional Fibre Channel Card Index FiguresPage Tables Page Related documentation About this guideDocument conventions Convention Element Document conventions and symbolsHP-authorized reseller HP technical supportHelpful web sites Page Models IntroductionAccessories Tape Drives Library tape drive locations Ultrium Tape DrivesHP Ultrium 960 format trademark Ultrium Tape CartridgesSdlt Tape Drives Sdlt Tape Cartridges Magazines Library power supplies Power SuppliesLibrary Controller Board RoboticsLibrary controller board Library controller board connections Factory-Defined Accessory PCI SlotsEmbedded Network Storage Router Optional Front Panel IndicatorsLibrary front panel Multi Unit Library SystemsLibrary PTM mounting location Converting a Tabletop Model to a Rackmount Model InstallationConverting a tabletop model four-drive model shown Setting Up the Rackmount ModelMSL6000 series tape library user guide Installation MSL6000 series tape library user guide Securing the library Converting a Rackmount Model to a Tabletop ModelConverting a rackmount model two-drive model shown Applying Power to the LibraryCabling for Scsi Configurations Two Tape Drives, Dual Host System Supported Scsi CablesFour Tape Drives, Dual Host System Changing Default Configuration Settings Library ConfigurationSetting a Scsi ID Library Configuration Setting Up a Reserved Slot #24 #23 #22 #21 #20 #19 #18 #17 #16 #15 #14 #13 #12 Reserved Slot NumberingReserved slot locations, Ultrium MSL6030 Reserved slot locations, lower module, Sdlt Cleaning Slot #2 Cleaning Slot #0 Cleaning Slot #1 Library Configuration IP address determination screen Configuring the Network SettingsLibrary Configuration Front Panel OperationMagazine Doors Magazine door mechanical releases emergency access Front Panel and Media Security Locks IndicatorsGUI Touch Screen Operation Initialization Screen Library Display Screens and OptionsLibrary Status Screen Host SystemOperation Magazine Access Mail Slot Access Left-hand Magazines OnlyTechnical Support Information Move Media Magazine access screen two-drive model shownGUI Contrast Controls Power Status Power-down confirmation message screenOnline Cartridge MapMenu View System Data Area Menu SelectionsLibrary Options Enabled Drive and Slot Numbering Scsi Options Module ConfigurationSCSI-3 PID Generate Unit Attention Reports Network Options Default view network options screenLibrary Info Edit Options AreaLibrary Scsi Utilities Area PasswordsNetwork Diagnostics screen four-drive model shown DiagnosticsFactory Inserting and Removing Tape CartridgesSecurity Level Removing tape cartridge magazines Removing MagazinesInserting Cartridges into a Magazine Using Mail Slots Left-hand Magazines OnlyLeft-hand magazine mail slot two-drive model shown Labeling Tape CartridgesAttaching a bar code label to an Ultrium tape cartridge Ultrium LabelsSdlt Labels Proper Ultrium bar code label placementAttaching a bar code label to an Sdlt tape cartridge Media Label IdentifiersOverview Remote Management InterfaceAccessing the Remote Management Interface MSL6000 series tape library user guide Status Using Menu ButtonsClick Execute the Move Move MediaSetup screen SetupLibrary configuration screen Drive Configuration Scsi ConfigurationFunctions History Changing the Remote Management Interface PasswordsMSL6000 series tape library user guide Remote Management Interface Using the Library Maintenance Menu MaintenanceMaintaining Tape Cartridges Ultrium Cartridges Sdlt Cartridges Running a Cleaning CartridgeManually Running a Cleaning Cartridge Automatically Running a Cleaning CartridgeRunning a Cleaning Cartridge from a Tape Cartridge Slot Running a Cleaning Cartridge from a Mail SlotRunning a Cleaning Cartridge from a Cleaning Slot Replacing a Cleaning Cartridge in a Right Magazine Replacing a Cleaning Cartridge in a Reserved SlotReplacing a Cleaning Cartridge in a Mail Slot Updating Firmware Updating firmware using the Remote Management InterfaceUsing a Serial Connection Using HP StorageWorks Library & Tape ToolsFirmware Flashing Procedure Maintenance Identifying Platform Problems TroubleshootingTroubleshooting flow chart Performing Error RecoveryERP Fault Symptom Codes FSCsEnsure Scsi options are set correctly FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC Null FSC FSC Magazine in the master module FSC FSC Troubleshooting General Problems Troubleshooting Run a Vertical Calibration test from Check the host device file system access permissions Lvds or single-ended Scsi and is properly installed RAID Using Diagnostic Support ToolsHP StorageWorks Library and Tape Tools Running Library Diagnostic TestsMSLUtil Their status Regulatory compliance identification numbers Regulatory compliance noticesFederal Communications Commission notice FCC rating labelModification Canadian notice Avis CanadienCables Class a equipmentJapanese notices European Union noticeClass B equipment Korean notices Japanese power cord statementTaiwanese notices Class a equipment Class B equipmentLaser compliance notices Taiwan battery recycle statementDutch laser notice French laser notice Italian laser notice German laser noticeJapanese laser notice Spanish laser notice Recycling noticesDutch notice Danish noticeCzecholslovakian notice French notice Estonian notice Finnish noticeGreek notice German noticeHungarian notice Italian notice Latvian notice Lithuanian notice Descarte de Lixo Elétrico na Comunidade Européia Polish notice Portuguese noticeSlovakian notice Slovenian notice Spanish notice Swedish notice Power SpecificationsMechanical Environmental All Models Acoustics Safety and RegulatorySpecifications Grounding Methods Electrostatic DischargeElectrostatic Discharge Scsi Cable Configurations Configuration ExamplesMSL6030/MSL6026, 2 hosts/2 drives Configuration ExamplesHost Prerequisites Optional Fibre Channel CardPower Indicator Connectors and IndicatorsSerial Port Scsi Vhdci Connectors ConfigurationDefault Ethernet Settings Ethernet PortMSL6030/MSL6026 standalone MSL6060/MSL6052 standalone Optional Fibre Channel Card FCC Index170 PTM 176 Figures Page Page Page Tables
Related manuals
Manual 18 pages 44.43 Kb