Table 6 View SCSI Options (continued)
Option | Description |
Init Element Status | Lets you specify the library’s response to the SCSI |
| INITIALIZE ELEMENT STATUS command. The |
| possible settings are No Inventory, Force Inventory, and |
| Force Label Scan. The default is Force Inventory. |
|
|
Test Unit Ready | Lets you specify the response to a TEST UNIT READY |
Reporting | command if the library is in Sequential Mode. The |
| possible settings are Standard or Custom. The default is |
| Custom. |
|
|
Device Capability Page | Lets you choose between two lengths of the mode |
Length | sense/select device capabilities page (SCSI page 1Fh), |
| which are Short (14 bytes) and Long (18 bytes), to |
| accommodate different SCSI device implementations of |
| this page. The default is Short (14 bytes). |
|
|
Transport Element | Lets you set the base address for the robotics mechanism. |
Base Address | The default is 0x0. |
|
|
Storage Element | Lets you set the base address for the magazine slots. The |
Base Address | default is 0x20. |
|
|
Transfer Element | Lets you set the base address for the tape drives. The |
Base Address | default is 0x1E0. |
|
|
Import/Export Element | Lets you set the base address for the mail slot. The default |
Base Address | is 0x1C0. |
|
|
Product Identification | Lets you specify the response of the library’s robotics to the |
(PID) | SCSI INQUIRY command in the Product Identification |
| field. The default is MSL6000 Series. |
|
|
Vendor Identification | Lets you specify the response of the library’s robotics to the |
(VID) | SCSI INQUIRY command in the Vendor Identification |
| field. The default is HP. |
|
|
Post Recovered Errors | Lets you specify whether or not recovered errors are |
| posted. The default is Disabled. |
|
|