HP MSL6000 manual Troubleshooting

Page 136

Table 11 Troubleshooting General Problems

Problem

Solution

Power

 

Library will not power on.

Check all power cord connections.

 

Make sure that each power switch is on.

 

Press anywhere on the GUI touch screen to activate

 

the display and turn on the library.

 

Verify that the LEDs on the back of the library are on

 

and that the fans are turning to ensure the library is

 

receiving power.

 

Replace the power cord(s).

 

Contact your authorized service provider.

 

 

One of the redundant power supplies

Check the LEDs on the power supplies to identify the

is not functioning properly.

one that may be at fault.

 

Check GUI for FSC code.

 

Contact your authorized service provider.

 

 

No display messages appear on the

Touch the GUI screen to bring out of sleep mode.

GUI touch screen.

Make sure the power cord is connected.

 

Make sure the power switches are on.

 

Check that the LEDs on the back of the library are on

 

and the fans are turning.

 

Cycle power to the library or reboot using the GUI

 

touch screen.

 

Try to access the library from the Web using the

 

Remote Management Interface (see page 79), or

 

through a host-based diagnostics tool such as HP

 

StorageWorks Library & Tape Tools (see page 98).

 

Download library firmware (see page 97).

 

Contact your authorized service provider.

 

 

Tape Movement

 

An error message appears after

Verify that tapes are inserted correctly in the

inserting the magazine or loading

magazine.

tapes.

Ensure that you are using the correct tape type for

 

your drive technology.

 

Contact your authorized service provider.

 

 

136 Troubleshooting

Image 136
Contents HP StorageWorks MSL6000 series tape library user guide Page Contents Operation Remote Management InterfaceTroubleshooting MaintenanceRegulatory compliance notices Specifications Configuration Examples Electrostatic DischargeOptional Fibre Channel Card Index FiguresPage Tables Page About this guide Related documentationDocument conventions and symbols Document conventions Convention ElementHP-authorized reseller HP technical supportHelpful web sites Page Introduction ModelsAccessories Tape Drives Ultrium Tape Drives Library tape drive locationsUltrium Tape Cartridges HP Ultrium 960 format trademarkSdlt Tape Drives Sdlt Tape Cartridges Magazines Power Supplies Library power suppliesRobotics Library Controller BoardLibrary controller board Factory-Defined Accessory PCI Slots Library controller board connectionsFront Panel Indicators Embedded Network Storage Router OptionalMulti Unit Library Systems Library front panelLibrary PTM mounting location Installation Converting a Tabletop Model to a Rackmount ModelSetting Up the Rackmount Model Converting a tabletop model four-drive model shownMSL6000 series tape library user guide Installation MSL6000 series tape library user guide Converting a Rackmount Model to a Tabletop Model Securing the libraryApplying Power to the Library Converting a rackmount model two-drive model shownCabling for Scsi Configurations Supported Scsi Cables Two Tape Drives, Dual Host SystemFour Tape Drives, Dual Host System Changing Default Configuration Settings Library ConfigurationSetting a Scsi ID Library Configuration Setting Up a Reserved Slot Reserved Slot Numbering #24 #23 #22 #21 #20 #19 #18 #17 #16 #15 #14 #13 #12Reserved slot locations, Ultrium MSL6030 Reserved slot locations, lower module, Sdlt Cleaning Slot #2 Cleaning Slot #0 Cleaning Slot #1 Library Configuration Configuring the Network Settings IP address determination screenLibrary Configuration Front Panel OperationMagazine Doors Magazine door mechanical releases emergency access Front Panel and Media Security Locks IndicatorsGUI Touch Screen Operation Library Display Screens and Options Initialization ScreenLibrary Status Screen Host SystemOperation Magazine Access Mail Slot Access Left-hand Magazines OnlyTechnical Support Information Magazine access screen two-drive model shown Move MediaPower GUI Contrast ControlsPower-down confirmation message screen StatusOnline Cartridge MapMenu View System Data Area Menu SelectionsLibrary Options Enabled Drive and Slot Numbering Module Configuration Scsi OptionsSCSI-3 PID Generate Unit Attention Reports Default view network options screen Network OptionsLibrary Info Edit Options AreaLibrary Scsi Utilities Area PasswordsNetwork Diagnostics Diagnostics screen four-drive model shownFactory Inserting and Removing Tape CartridgesSecurity Level Removing Magazines Removing tape cartridge magazinesUsing Mail Slots Left-hand Magazines Only Inserting Cartridges into a MagazineLabeling Tape Cartridges Left-hand magazine mail slot two-drive model shownUltrium Labels Attaching a bar code label to an Ultrium tape cartridgeProper Ultrium bar code label placement Sdlt LabelsMedia Label Identifiers Attaching a bar code label to an Sdlt tape cartridgeRemote Management Interface OverviewAccessing the Remote Management Interface MSL6000 series tape library user guide Using Menu Buttons StatusMove Media Click Execute the MoveSetup Setup screenLibrary configuration screen Scsi Configuration Drive ConfigurationFunctions Changing the Remote Management Interface Passwords HistoryMSL6000 series tape library user guide Remote Management Interface Maintenance Using the Library Maintenance MenuMaintaining Tape Cartridges Running a Cleaning Cartridge Ultrium Cartridges Sdlt CartridgesAutomatically Running a Cleaning Cartridge Manually Running a Cleaning CartridgeRunning a Cleaning Cartridge from a Tape Cartridge Slot Running a Cleaning Cartridge from a Mail SlotRunning a Cleaning Cartridge from a Cleaning Slot Replacing a Cleaning Cartridge in a Right Magazine Replacing a Cleaning Cartridge in a Reserved SlotReplacing a Cleaning Cartridge in a Mail Slot Updating firmware using the Remote Management Interface Updating FirmwareUsing HP StorageWorks Library & Tape Tools Using a Serial ConnectionFirmware Flashing Procedure Maintenance Troubleshooting Identifying Platform ProblemsPerforming Error Recovery Troubleshooting flow chartFault Symptom Codes FSCs ERPEnsure Scsi options are set correctly FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC Null FSC FSC Magazine in the master module FSC FSC Troubleshooting General Problems Troubleshooting Run a Vertical Calibration test from Check the host device file system access permissions Lvds or single-ended Scsi and is properly installed Using Diagnostic Support Tools RAIDHP StorageWorks Library and Tape Tools Running Library Diagnostic TestsMSLUtil Their status Regulatory compliance notices Regulatory compliance identification numbersFederal Communications Commission notice FCC rating labelCanadian notice Avis Canadien ModificationCables Class a equipmentJapanese notices European Union noticeClass B equipment Japanese power cord statement Korean noticesTaiwanese notices Class a equipment Class B equipmentTaiwan battery recycle statement Laser compliance noticesDutch laser notice French laser notice German laser notice Italian laser noticeRecycling notices Japanese laser notice Spanish laser noticeDutch notice Danish noticeCzecholslovakian notice Estonian notice Finnish notice French noticeGerman notice Greek noticeHungarian notice Italian notice Latvian notice Lithuanian notice Polish notice Portuguese notice Descarte de Lixo Elétrico na Comunidade EuropéiaSlovakian notice Slovenian notice Spanish notice Swedish notice Power SpecificationsMechanical Environmental All Models Safety and Regulatory AcousticsSpecifications Electrostatic Discharge Grounding MethodsElectrostatic Discharge Configuration Examples Scsi Cable ConfigurationsConfiguration Examples MSL6030/MSL6026, 2 hosts/2 drivesOptional Fibre Channel Card Host PrerequisitesPower Indicator Connectors and IndicatorsSerial Port Configuration Scsi Vhdci ConnectorsDefault Ethernet Settings Ethernet PortMSL6030/MSL6026 standalone MSL6060/MSL6052 standalone Optional Fibre Channel Card Index FCC170 PTM 176 Figures Page Page Page Tables