Table 10 Fault Symptom Codes (continued) |
|
| |
|
|
| |
FSC | Message | ERP | |
307A | Diag get drive 2 status failed | • | Press the Enter button to reboot. |
| (Failed to get drive status, communication | • | Ensure the drive shows good status |
| error.) |
| through the drive status window. |
|
| • Deactivate the drive using the GUI control | |
|
|
| panel maintenance menu. |
|
| • | Reseat drive. |
|
| • | Check cabling. |
|
| • Load/unload a cartridge to the drive to | |
|
|
| verify. |
|
| • Check the tape cartridge used in the last | |
|
|
| operation for damage. |
|
| • Run the cartridge cycle diagnostic to | |
|
|
| verify. |
|
|
|
|
307B | Diag get drive 3 status failed | • | Press the Enter button to reboot. |
| (Failed to get drive status, communication | • | Ensure the drive shows good status |
| error.) |
| through the drive status window. |
|
| • Deactivate the drive using the GUI control | |
|
|
| panel maintenance menu. |
|
| • | Reseat drive. |
|
| • | Check cabling. |
|
| • Load/unload a cartridge to the drive to | |
|
|
| verify. |
|
| • Check the tape cartridge used in the last | |
|
|
| operation for damage. |
|
| • Run the cartridge cycle diagnostic to | |
|
|
| verify. |
|
|
|
|
3082 | Drive Stow Failed, Media Returned to | • | Press the Enter button to clear the |
| Source |
| message. |
|
| • Use only media approved for the drive | |
|
|
| type. |
|
| • Invalid user initiated operation. Set | |
|
|
| parameters correctly and try again. |
|
|
|
|
3083 | Drive Stow Failed, Media Remains in | • | Press the Enter button to clear the |
| Drive |
| message. |
|
| • Invalid user initiated operation. Set | |
|
|
| parameters correctly and try again. |
|
| • Ensure cartridges are in magazines. | |
|
|
|
|