Table 10 Fault Symptom Codes (continued) |
|
| |
|
|
| |
FSC | Message | ERP | |
305B | Diag Fetch, Drive not loaded | • | Press the Enter button to clear the |
| (Diag: no cartridge present for fetch.) |
| message. |
| • | Load a cartridge in the drive and retry | |
|
| ||
|
|
| the operation. |
|
| • Invalid user initiated operation. Set | |
|
|
| parameters correctly and try again. |
|
|
|
|
305D | Diag Timeout waiting for drive empty, | • | Press the Enter button to reboot. |
| ready | • | Invalid user initiated operation. Set |
| (Fetch, |
| parameters correctly and try again. |
|
| • Ensure the drive shows good status | |
|
|
| through the drive status window. |
|
| • Check the tape cartridge used in the last | |
|
|
| operation for damage. |
|
|
|
|
305F | Invalid bin number | • | Press the Enter button to clear the |
| (Invalid bin number detected in diag.) |
| message. |
| • | Invalid user initiated operation. Set | |
|
| ||
|
|
| parameters correctly and try again. |
|
|
|
|
3060 | Zone Sequence Error | • | Cycle power to the library or reboot |
| (Robot did not find sensor on |
| using the GUI touch screen. |
|
|
| |
|
|
|
|
3074 | Drive 0 Eject Failed | • | Press the Enter button to reboot. |
| (Eject command | • | Ensure the drive shows good status |
|
|
| through the drive status window. |
|
| • Deactivate the drive using the GUI control | |
|
|
| panel maintenance menu. |
|
| • | Reseat drive. |
|
| • Load/unload a cartridge to the drive to | |
|
|
| verify. |
|
| • Check the tape cartridge used in the last | |
|
|
| operation for damage. |
|
| • Run the cartridge cycle diagnostic to | |
|
|
| verify. |
|
|
|
|
116 Troubleshooting