Table 10 Fault Symptom Codes (continued)

 

 

 

 

FSC

Message

ERP

5014

Drive Already Loaded

Press the Enter button to clear the

 

(Cleaning operation failed because the

message.

 

Invalid user initiated operation. Set

 

drive already has a cartridge inserted.)

 

 

parameters correctly and try again.

 

 

If the tape in the drive is not in use,

 

 

unload the drive and retry the cleaning

 

 

operation.

 

 

 

5015

Expired Clean'g Cart

Press the Enter button to clear the

 

(Cleaning operation failed due to an

message.

 

Remove expired cleaning cartridge from

 

expired cleaning cartridge.)

 

 

library and discard. Replace with new

 

 

cleaning cartridge.

 

 

 

5016

Not a Clean'g Cart

Press the Enter button to clear the

 

(Cleaning operation failed because the

message.

 

Make sure tape in reserved slot is a

 

loaded cartridge is not a cleaning

 

cartridge.)

cleaning cartridge.

 

 

Invalid user initiated operation. Set

 

 

parameters correctly and try again.

 

 

 

5035

Drive Timeout Error

Press the Enter button to clear the

 

(Cleaning operation failed because the

message.

 

Invalid user initiated operation. Set

 

drive timed out.)

 

 

parameters correctly and try again.

 

 

Ensure the drive shows good status

 

 

through the drive status window.

 

 

 

503B

Move Command Fail

Press the Enter button to clear the

 

(A front panel move operation failed.)

message.

 

Invalid user initiated operation. Set

 

 

 

 

parameters correctly and try again.

 

 

 

503C

Clean Operation Timeout

Press the Enter button to clear the

 

(Cleaning operation failed because the

message.

 

Invalid user initiated operation. Set

 

drive timed out.)

 

 

parameters correctly and try again.

 

 

Ensure the drive shows good status

 

 

through the drive status window.

 

 

 

MSL6000 series tape library user guide 125

Image 125
Contents HP StorageWorks MSL6000 series tape library user guide Page Contents Remote Management Interface OperationRegulatory compliance notices MaintenanceTroubleshooting Specifications Electrostatic Discharge Configuration ExamplesOptional Fibre Channel Card Index FiguresPage Tables Page Related documentation About this guideDocument conventions Convention Element Document conventions and symbolsHelpful web sites HP technical supportHP-authorized reseller Page Models IntroductionAccessories Tape Drives Library tape drive locations Ultrium Tape DrivesHP Ultrium 960 format trademark Ultrium Tape CartridgesSdlt Tape Drives Sdlt Tape Cartridges Magazines Library power supplies Power SuppliesLibrary Controller Board RoboticsLibrary controller board Library controller board connections Factory-Defined Accessory PCI SlotsEmbedded Network Storage Router Optional Front Panel IndicatorsLibrary front panel Multi Unit Library SystemsLibrary PTM mounting location Converting a Tabletop Model to a Rackmount Model InstallationConverting a tabletop model four-drive model shown Setting Up the Rackmount ModelMSL6000 series tape library user guide Installation MSL6000 series tape library user guide Securing the library Converting a Rackmount Model to a Tabletop ModelConverting a rackmount model two-drive model shown Applying Power to the LibraryCabling for Scsi Configurations Two Tape Drives, Dual Host System Supported Scsi CablesFour Tape Drives, Dual Host System Setting a Scsi ID Library ConfigurationChanging Default Configuration Settings Library Configuration Setting Up a Reserved Slot #24 #23 #22 #21 #20 #19 #18 #17 #16 #15 #14 #13 #12 Reserved Slot NumberingReserved slot locations, Ultrium MSL6030 Reserved slot locations, lower module, Sdlt Cleaning Slot #2 Cleaning Slot #0 Cleaning Slot #1 Library Configuration IP address determination screen Configuring the Network SettingsLibrary Configuration Magazine Doors OperationFront Panel Magazine door mechanical releases emergency access GUI Touch Screen IndicatorsFront Panel and Media Security Locks Operation Initialization Screen Library Display Screens and OptionsLibrary Status Screen Host SystemOperation Technical Support Information Mail Slot Access Left-hand Magazines OnlyMagazine Access Move Media Magazine access screen two-drive model shownGUI Contrast Controls PowerStatus Power-down confirmation message screenMenu Cartridge MapOnline Library Options Menu SelectionsView System Data Area Enabled Drive and Slot Numbering Scsi Options Module ConfigurationSCSI-3 PID Generate Unit Attention Reports Network Options Default view network options screenLibrary Edit Options AreaLibrary Info Scsi Network PasswordsUtilities Area Diagnostics screen four-drive model shown DiagnosticsSecurity Level Inserting and Removing Tape CartridgesFactory Removing tape cartridge magazines Removing MagazinesInserting Cartridges into a Magazine Using Mail Slots Left-hand Magazines OnlyLeft-hand magazine mail slot two-drive model shown Labeling Tape CartridgesAttaching a bar code label to an Ultrium tape cartridge Ultrium LabelsSdlt Labels Proper Ultrium bar code label placementAttaching a bar code label to an Sdlt tape cartridge Media Label IdentifiersOverview Remote Management InterfaceAccessing the Remote Management Interface MSL6000 series tape library user guide Status Using Menu ButtonsClick Execute the Move Move MediaSetup screen SetupLibrary configuration screen Drive Configuration Scsi ConfigurationFunctions History Changing the Remote Management Interface PasswordsMSL6000 series tape library user guide Remote Management Interface Using the Library Maintenance Menu MaintenanceMaintaining Tape Cartridges Ultrium Cartridges Sdlt Cartridges Running a Cleaning CartridgeManually Running a Cleaning Cartridge Automatically Running a Cleaning CartridgeRunning a Cleaning Cartridge from a Cleaning Slot Running a Cleaning Cartridge from a Mail SlotRunning a Cleaning Cartridge from a Tape Cartridge Slot Replacing a Cleaning Cartridge in a Mail Slot Replacing a Cleaning Cartridge in a Reserved SlotReplacing a Cleaning Cartridge in a Right Magazine Updating Firmware Updating firmware using the Remote Management InterfaceUsing a Serial Connection Using HP StorageWorks Library & Tape ToolsFirmware Flashing Procedure Maintenance Identifying Platform Problems TroubleshootingTroubleshooting flow chart Performing Error RecoveryERP Fault Symptom Codes FSCsEnsure Scsi options are set correctly FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC FSC Null FSC FSC Magazine in the master module FSC FSC Troubleshooting General Problems Troubleshooting Run a Vertical Calibration test from Check the host device file system access permissions Lvds or single-ended Scsi and is properly installed RAID Using Diagnostic Support ToolsMSLUtil Running Library Diagnostic TestsHP StorageWorks Library and Tape Tools Their status Regulatory compliance identification numbers Regulatory compliance noticesFederal Communications Commission notice FCC rating labelModification Canadian notice Avis CanadienCables Class a equipmentClass B equipment European Union noticeJapanese notices Korean notices Japanese power cord statementTaiwanese notices Class a equipment Class B equipmentLaser compliance notices Taiwan battery recycle statementDutch laser notice French laser notice Italian laser notice German laser noticeJapanese laser notice Spanish laser notice Recycling noticesCzecholslovakian notice Danish noticeDutch notice French notice Estonian notice Finnish noticeGreek notice German noticeHungarian notice Italian notice Latvian notice Lithuanian notice Descarte de Lixo Elétrico na Comunidade Européia Polish notice Portuguese noticeSlovakian notice Slovenian notice Spanish notice Swedish notice Mechanical SpecificationsPower Environmental All Models Acoustics Safety and RegulatorySpecifications Grounding Methods Electrostatic DischargeElectrostatic Discharge Scsi Cable Configurations Configuration ExamplesMSL6030/MSL6026, 2 hosts/2 drives Configuration ExamplesHost Prerequisites Optional Fibre Channel CardSerial Port Connectors and IndicatorsPower Indicator Scsi Vhdci Connectors ConfigurationDefault Ethernet Settings Ethernet PortMSL6030/MSL6026 standalone MSL6060/MSL6052 standalone Optional Fibre Channel Card FCC Index170 PTM 176 Figures Page Page Page Tables