Table 10 Fault Symptom Codes (continued) |
| |
|
|
|
FSC | Message | ERP |
3110 | Picker Retries Exceeded | • Cycle power to the library or reboot by |
|
| using the LCD touch display. |
|
| • Run cartridge cycle test using the LCD |
|
| touch display. (Menu |
|
| Diagnostic options) |
|
| Note: If the backup application is running, |
|
| update the application cartridge map. |
|
|
|
3111 | Picker Retries Exceeded 1 | • Press the Enter button to reboot. |
| (Picker retries exceeded during a | • Cycle power to the library or reboot |
| using the GUI touch screen. | |
|
| • Check |
|
|
|
3112 | Picker Retries Exceeded 2 | • Cycle power to the library or reboot by |
|
| using the LCD touch display. |
|
| • Run cartridge cycle test using the LCD |
|
| touch display. (Menu |
|
| Diagnostic options) |
|
| Note: If the backup application is running, |
|
| update the application cartridge map. |
|
|
|
3113 | Picker Retries Exceeded 3 | • Press the Enter button to reboot. |
| (Picker retries exceeded during a bin stow | • Cycle power to the library or reboot |
| operation.) | using the GUI touch screen. |
|
| • Ensure that there are no obstructions |
|
| inside the library (all cartridges are in |
|
| magazines). |
|
| • Ensure cartridges are fully inserted in the |
|
| magazine(s). |
|
|
|
3115 | Picker Retraction Error | • Press the Enter button to reboot. |
| (Picker did not retract during a bin check | • Cycle power to the library or reboot |
| operation.) | using the GUI touch screen. |
|
|
|
3200 | Shuttle Jammed | • Press the Enter button to reboot. |
| (Shuttle could not reach target location.) | • Check |
|
| alignment. |
|
| • Cycle power to the library or reboot |
|
| using the GUI touch screen. |
|
|
|