Configuration
Configuring the X.25 Link
Figure | Verify Level 3 Values |
Step | 2. Enter or modify field values as required (refer to the field descriptions | ||
|
| below). |
|
Table |
| Verify Level 3 Values Field Descriptions | |
|
|
|
|
|
| Fast Select | If fast select is enabled (Yes), up to 128 octets of |
|
| Accepted | information can be transferred in call request and |
|
|
| clear packets. The default is No (disabled). See |
|
|
| your subscription form. |
|
|
|
|
|
| Flow Control | The default is No (disabled). Use the value given |
|
| Negotiation | on your subscription form. |
|
|
|
|
|
| Reverse Charge | If reverse charge is enabled (Yes), reverse charge |
|
| Accepted | calls can be accepted by the application. If reverse |
|
|
| charge is disabled (No), X.25 rejects reverse |
|
|
| charge calls automatically. The default is No. Use |
|
|
| the value given on your subscription form. |
|
|
|
|
|
| Throughput Class | Throughput class refers to line speed. If it is |
|
| Negotiation | enabled (Yes), the Switched VC Negotiated value |
|
|
| is used; if disabled (No), no throughput class |
|
|
| negotiation is accepted. The default is No. |
|
|
|
|
42 | Chapter 3 |