Configuration
Configuring the High Availability Feature
#e.g.# SERVICE_NAME [1] = <other name>
#SERVICE_CMD [1] = <other monitor>
#START OF CUSTOMER DEFINED FUNCTIONS function customer_defined_run_cmds
{
#ADD customer defined run commands
: # do nothing instruction, because a function must contain at least one command. x25init
sleep 5
test_return 51
}
function customer_defined_halt_cmds
{
#ADD customer defined halt commands
: # do nothing instruction, because a function must contain some command. #stopping the specific X.25 card means the signal modem will be down x25stop
test_return 52
}
Checking the Configuration
Check that your configuration is correct using x25server, x25check, and ping.
x25server Run the x25server command. This starts a background process that waits for packets from an x25check command and sends a reply.
x25check Execute the x25check command, using your X.121 address:
$ x25check 250207
X25CHECK (c) COPYRIGHT
Test Starts on .. Wed Dec 8 09:15:01 1993
Initialization of the test...
CALL packet sent ...
The following figures have been measured on the network:
Set up time : 267 ms
Remote Connection Succeeded
Execute the x25check command again, but this time with data packets:
82 | Chapter 3 |