Configuration
Configuring the X.25 Link
Table | Modify Throughput Class Settings Field Descriptions | |
|
|
|
| Switched VC | CCITT class number. If Throughput Class |
| Negotiated: | negotiation is enabled, this value is used as the |
| Inbound and | opening bid for outbound calls and as a counter |
| Outbound | offer when the inbound opening bid is higher. The |
|
| range is 3 through 13, and the default is 11. See |
|
| the table below for CCITT class numbers and |
|
| corresponding line speed Baud rate. Use the |
|
| value given on your subscription form. |
|
|
|
Table |
| Throughput Classes and Line Speeds | ||
|
|
|
|
|
|
| CCITT class number |
| Line speed Baud rate (bps) |
|
|
|
|
|
|
| 3 |
| 75 |
|
|
|
|
|
|
| 4 |
| 150 |
|
|
|
|
|
|
| 5 |
| 300 |
|
|
|
|
|
|
| 6 |
| 600 |
|
|
|
|
|
|
| 7 |
| 1200 |
|
|
|
|
|
|
| 8 |
| 2400 |
|
|
|
|
|
|
| 9 |
| 4800 |
|
|
|
|
|
|
| 10 |
| 9600 |
|
|
|
|
|
|
| 11 |
| 19200 |
|
|
|
|
|
|
| 12 |
| 48000 |
|
|
|
|
|
|
| 13 |
| 64000 |
|
|
|
| |
Step | 7. Click on OK to return to the “Configure X.25 Card” window when you | |||
|
| have finished verifying level 3 values. |
|
Verifying Level 2 Values
Follow the steps below to verify level 2 values: