| Configuration |
|
| Configuring PAD Services |
Step | 1. | At the SAM main window, highlight “Networking and Communications” |
|
| and select Open Item from the Actions menu. |
Step | 2. | At the “Networking and Communications” window, highlight X.25 PAD |
|
| Services and select Open Item from the Actions menu. |
Step | 3. | Highlight UUCP Server and select Open Item from the Actions menu. |
|
| SAM lists all remote systems currently configured for X.25 PAD UUCP |
|
| connectivity. |
Step | 4. | Select Add from the Actions menu to configure PAD UUCP connectivity |
|
| for an unlisted remote system, or highlight a remote system from the list |
|
| and select Modify. |
Step | 5. | Enter or modify field values as required. |
Step | 6. | Click on Apply to apply the new settings and to add additional PAD |
|
| UUCP connections. Click on OK to save changes and exit this dialog. |
Step | 7. | Select Exit from the List menu to return to the “X.25 PAD Services” |
|
| dialog. |
Step | 8. | If necessary, select the next PAD service you need to configure from the |
|
| list. |
In order for PAD UUCP connectivity to function correctly, UUCP must also be configured. If you have not already done this, you can configure UUCP by returning to the “Networking and Communications” window, highlighting UUCP and selecting Open Item from the Actions menu.
From this dialog you can configure UUCP Devices and/or UUCP Remote Systems (see the
Add/Modify X.3 Parameters
Follow the steps below to add or modify X.3 parameters. Refer to Chapter 6, PAD Services, for detailed descriptions of the X.3 parameters.
Chapter 3 | 77 |