Pump Pressure
Adjustment
1.Remove pressure gauge plug from filter end cover.
2.Install accessory pressure gauge (part number HA1180).
3.Start heater (see Operation, page 7). Allow motor to reach full speed.
4.Adjust pressure. Turn relief valve to right to increase pressure. Turn relief valve to left to decrease pressure. Set pump pressure at 4.9 psi.
5.Remove pressure gauge. Replace pressure gauge plug in filter end cover.
Nozzle
1.Remove upper shell (see page 10).
2.Remove fan (see page 14).
3.Remove spark plug wire from spark plug.
4.Remove spark plug from burner head using 13/16"
5.Loosen flare nut using 3/4"
6.Remove air line hose from burner head.
7.Remove three screws using 5/16"
8.Place burner head into vise and lightly tighten.
9.Carefully remove nozzle from burner head using 5/8" socket wrench (see Figure 13).
10.Blow compressed air thru face of nozzle. This will free any dirt in nozzle area.
11.Inspect nozzle seal for damage.
12
Relief
Valve
Pressure
Gauge
Plug
150 PRESSURE ADJUSTMENT Plug PF
Figure 10 - Pressure Gauge Plug Removal
Pressure
Gauge
150 PRESSURE ADJUSTMENTPF
Figure 11 - Adjusting Pump Pressure
Combustion
Chamber
Burner Head
Screw
Air Line Hose
Flare Nut
Fuel Tube
Figure 12 - Removing Burner Head
Spark Plug Wire
Spark
Plug
101487