PREPARING THE ROOM HEATER LOCATION
1.Select an installation location that will give the best airflow from the front of the heater to the remainder of the home.
2.Place the protective floor pad in position.
3.Place the unit on the pad making sure the minimum clearance specifications are met.
4.If connecting to an existing masonry flue, first ensure that the flue conforms to the
CHIMNEY
This room heater must be converted to (1) a chimney complying with the requirements for Type HT chimneys in the Standard for Chimneys,
CAUTION: Certain installation types require the use of certain chimney types. Please follow these instructions exactly.
DETERMINING THE CHIMNEY LOCATION
A.Ceiling Exit (Using Single Wall Pipe)
1.Suspend a plumb bob from the ceiling above the unit so that the weight is hanging in the center of the flue exit. (A small weight on a string will serve as a plumb bob.) Mark the ceiling where the string is suspended to locate the center of the chimney.
2.After locating the center of the hole, install the ceiling support box, chimney or chimney connector, flashing, and rain cap per the chimney manufacturer’s instructions, and local building codes for installation through combustible walls or ceilings.
3.Now connect the stove and ceiling support box using #24 ga. minimum blued or black steel connector pipe (DO NOT USE GALVANIZED PIPE). Connect each section so the crimped end faces downward, and secure each section to each other using at least three (3) sheet metal screws or rivets. Single wall pipe is to be connected with 3 screws or rivets to New Buck Corporation Chimney Connector after connector has been attached to stove. (See Figure 5)