Heat & Glo LifeStyle ESC-42ST owner manual Appliance Preparation, Top Vent

Page 34

9 Appliance Preparation

A. Top Vent

CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

NOTICE: This appliance is top vented ONLY.

1. Remove shrink wrap from appliance.

NON-COMBUSTIBLE ASSEMBLY AND FINISHING STRIPS

Figure 9.1 Packaged Appliance.

2.The seal cap, shown in Figure 9.2, is included to pre- vent construction material from getting into appliance. Remove seal cap when pipe installation phase begins.

SEAL CAP

Figure 9.2 Seal Cap.

3.Remove the two non-combustible assemblies by re- moving the two 1/4 in. screws fastening the non-com- bustible assemblies to the appliance. See Figure 9.3.

4.Six sheet metal finishing strips are included with the appliance. The shipping location of the finishing strips is shown in Figure 9.3. Remove 1/4 in. screws that at- tach the strips to the appliance. Strips may be used during the final finishing steps of appliance setup. See Figure 9.7. Strips should be removed when finishing is completed.

SHIPPING BRACKET SCREWS

FINISHING STRIPS

Figure 9.3 Shipping Brackets and Finishing Strip Locations.

4.Once the appliance is finished into the wall and is ready for final installation, remove the rest of the com- ponents.

SPLATTER GUARD

OUTER HEARTH

REFRACTORY

Figure 9.4.

MESH RODS (2)

Figure 9.5 Mesh Rod Location, Gas Valve Side of Appliance.

34

Heat & Glo • ESC-42ST2146-900 Rev. o • 5/12

Image 34
Contents What to do if you smell gas Model ESC-42STDo Discardnot Congratulations Homeowner Reference InformationTable of Contents User GuideTroubleshooting Appliance SetupReference Materials Limited Lifetime Warranty Limited Lifetime Warranty Warranty ConditionsListing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Clear Space Fixed Glass AssemblyRemote Control Decorative Doors and FrontsNine Hour Safety Shutdown Feature IPI Battery Tray/Battery InstallationModule Reset Control Module OperationLighting Instructions IPI Final inspection byFrequently Asked Questions After Fireplace is LitGlass Cleaning Exterior of Installed Glass Only Maintenance and ServiceMaintenance Tasks-Homeowner Doors, Surrounds, FrontsGasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianGlass Cleaning Exterior and Interior of Installed Glass LogsLight Bulb Maintenance Frequency As neededGetting Started Typical Appliance SystemTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Selecting Appliance Location Framing and ClearancesBoard not Shown Attached to Constructing the Appliance Chase Minimum Framing DimensionsClearances Mantel and Wall Projections MIN MAX NON-COMBUSTIBLE Material Fireplace OpeningHearth Extension Combustible MaterialTermination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Inches U.S.AVent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsVent Diagrams Two Elbows Top Vent Horizontal TerminationTop Vent Horizontal Termination One Elbow H1+ H2Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft 15.2 m Max Ht Max Wall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Non-Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVPFlat Ceiling Installation Install Attic Insulation ShieldVaulted Ceiling Installation Appliance Preparation Top VentSecuring and Leveling the Appliance Appliance Package IdentificationAssemble Vent Sections Installing Vent PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsAssemble Slip Sections Secure the Vent Sections10 Rotate Seams for Disassembly Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Horizontal Termination Cap Install Vertical Termination CapHeat Shield Requirements for Horizontal Termination Gas Pressure Gas InformationFuel Conversion Gas ConnectionElectrical Service and Repair Junction Box Installation Wiring RequirementsIntelliFire Plus Ignition System Wiring Electrical InformationIPI Wiring Diagram Finishing Facing Material DoorsElevated Hearth Systems Model Description Elevated Appliance DimensionESC-42ST Appliance Setup TABInstalling the Optional Heat-ZoneGas Kit Clean the ApplianceAccessories Remove the Shipping MaterialsAccent Lights Install Light BulbsEmber Lights ScrewsFlange Install RefractoryNotch Outer Firebox Flange Refractory ClipsInstall Teco-Sil Glass Ember Rock Mystic Ember PlacementLOG Placement Instructions Grate BAR Grate Tine 4 Ember/Mineral Wool Placement Install Outer Refractory PanelsAir Shutter Setting Install MeshInstall Trim and/or Surround Air Shutter SettingsSymptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Troubleshooting Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP-AS2DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-TRAPRF6M RF12M Optional Wire Harness Description Part NumberRefractory Assembly Log Set Assembly Service PartsAt Depot Service Parts ListDescription Comments Part Number Pre SN Stocked#28 IPI Valve Assembly Post SN Contact Information